Control sources

Advertisement

Control Sources
Descriptions of Control sources
Descriptions of Control sources
This section is organized into two sets of descriptions: the MIDI Control Source list, and the
rest of the control sources. The numeral preceding the name of each control source can be
entered on the alphanumeric pad to select the control source directly (press ENTER after typing
the numeral).
Many of the MIDI control sources are assigned as default values for the control assignment
parameters on the MIDI mode XMIT page and the Setup Editor page. We'll indicate these
assignments as they appear, simply by mentioning that they're the default control source for a
control assignment parameter.
MIDI Control Source List
With a few exceptions, the MIDI control sources correspond to the standard MIDI controller
numbers used by every MIDI device.
128
0, 33
1
2
3
4
5
6
6-4
OFF
This value eliminates the effect of any control source parameter to which it's as-
signed.
MONO PRESSURE (MPress)
Many of the K2500's factory programs are assigned to modify parameters such as
pitch, filter cutoff frequency, and depth control when MPress messages are re-
ceived. The mono pressure (Press) control assignment parameters in MIDI and Set-
up modes are set by default to transmit MPress messages when mono pressure
messages are received from a controller.
MIDI 01 (MWheel)
Many factory programs are assigned to respond to MWheel messages. The Mod
Whl parameter in MIDI and Setup modes is set by default to transmit MWheel.
MIDI 02 (Breath)
MIDI 03
MIDI 04 (Foot)
This is the standard MIDI controller number for continuous control foot pedals. It's
the default value for the CPedal control assignment parameter, so a control pedal
on your MIDI controller which sends MIDI controller 04 messages will send MIDI
controller 04 messages to the K2500 by default.
MIDI 05 (PortTim)
This is the standard MIDI controller number for portamento time control. The
K2500 always responds to this control message. For any program that has porta-
mento turned on (on the COMMON page in the Program Editor), MIDI Portamen-
to Time messages received via MIDI will affect the rate of the program's
portamento.
MIDI 06 (Data)
MIDI 06 is the standard MIDI controller number for data entry. The Slider param-
eter on the MIDI mode XMIT page and in the Setup Editor is set by default to trans-