Virtual Environments - Novell SENTINEL 6.1 SP2 - INSTALLATION GUIDE 02-2010 Installation Manual

Hide thumbs Also See for SENTINEL 6.1 SP2 - INSTALLATION GUIDE 02-2010:
Table of Contents

Advertisement

Function
Database (Oracle)
Collector Manager 1 and secondary
DAS_Binary process
Collector Manager 2
Crystal Reports Server
System Setup for High-Performance Production Configuration
Table 2-9
Attribute
Collectors deployed per Collector
Manager
Rules deployed per correlation Engine
Active Views running
Number of simultaneous users
Number of maps deployed

2.2.6 Virtual Environments

Sentinel 6.1 has been tested extensively on VMware* ESX Server, and Novell fully supports
Sentinel running in this environment. Performance results in a virtual environment can be
comparable to the results achieved in tests on a physical machine, the virtual environment should
provide the same memory, CPU, disk space, and I/O as the physical machine recommendations.
26
Sentinel 6.1 Installation Guide
Sizing
Model
4 GB RAM
SLES 10 SP1, two 64-bit dual core
processors (tested with two Opteron
4 TB+ disk space
275s, 2.2 GHz), StorCase disk array,
and software RAID 5
4 GB RAM
SLES 10 SP1, two 64-bit dual core
processors (tested with two Opteron
40 GB disk space
275s, 2,2 GHz)
4 GB RAM
Windows 2003, one dual core processor
(tested with dual core Intel Xeon, 2.50
20 GB disk space
GHz)
4 GB RAM
One 32-bit dual core processor (tested
with Intel Xeon 5150, 2.66 GHz)
40 GB disk space
Rating
Comments
10
The Collector Manager 1 configuration
handles up to 1750 EPS; the Collector
Manager 2 configuration handles up to
850 EPS. A typical collector running
alone can output up to 600 EPS, but
adding more collectors to a Collector
Manager or using collectors with more
complex parsing will reduce the per-
collector output.
20
20
4
5
The largest map is 40 KB with over 800
rows.