Specifications And Dimensions; Troubleshooting - Semtronics 62533 Installation And Operating Instructions Manual

Semtronics ethernet adapter installation and operating instructions 62533

Advertisement

Specifications and Dimensions:

Dimensions:
Length:
3.882" in / 9.860cm
Width:
1.679" in / 4.264cm
Depth:
0.983" in / 2.496cm
Weight:
2.29 oz
/ 65 g

Troubleshooting:

Link LED or ACT not turning on when unit is powered
-
Power down unit, re-power unit and push and hold reset button for 10-12 seconds.
Software cannot find or conflicts within comports
-
Make sure you have the Diagnostic Loop Back securely connected to the serial port of model 50461.
-
Make sure Ethernet cable is not defective or incorrectly wired.
-
If you have a Lantronix comport redirector installed on the same computer, you will need to un-install the
software.
-
Unit not communicating with software
-
Make sure dip is set to dip 1 on and dip 2 to 4 is off.
-
Make sure Ethernet cable is not defective or incorrectly wired.
-
Make sure the DB9 Adapter is securely connected to the serial port of model 50461
-
Make sure you have the 24" data cable from the Ethernet connect to right port of
Smartlog X3 (labeled RS-232)
TB-6128 Page 6 of 7
Operation Temperature:
Ambient temperature: 10ºC to 45ºC (50ºF to 131ºF)
Relative humidity: 5% to 90% (non-condensing)
Power Requirement:
9-30Vdc @ 0.5A max
Regulatory Approval:
FCC Part 15 Subpart B, Class A
EN55022, Class A
EN55024
EN61000-3-2,3
UL60950
CAN/CSA C22.2 No.60950
EN60950
Figure 4.
Revision 10/06
© 2005 DESCO INDUSTRIES INC.
Employee Owned