Step Five: Install peripheral cabling

You can connect printers, terminals, modems (or any other standard EIA-
232 device to be controlled by applications on the computer) to the
EPC/CON-16 concentrator by installing a cable between the peripheral
and the concentrator.
On the peripheral end of the cable, the cable connector depends on the
requirements of the peripheral. The EPC/CON-16 (or PORTS/Xem mod-
ule) end of the cable must fit either an RJ-45 or DB-25 connector,
depending on the model you have.
The pin assignments for each type of EPC/CON-16 connector are as fol-
lows:
DB-25 Pin assignments
Signal
Description
GND
Chassis Ground
TxD
Transmitted Data
RxD
Received Data
RTS
Request To Send
CTS
Clear To Send
DSR
Data Set Ready
SG
Signal Ground
DCD
Data Carrier Detect
DTR
Data Terminal Ready
RI
Ring Indicator
* Chassis Ground is also available on the
connector shell
RJ-45 pin assignments are shown on the back.
RJ-45 Pin Assignments
Signal
DSR
RTS
GND
TxD
RxD
CTS
DTR
DCD
Pin
† Pin 2 can be configured for DCD (through Digi
software) if you want to connect using an 8 pin
1*
2
3
Refer to the CD-ROM for more detailed cabling information.
4
What Next?
5
6
At this point the hardware installation for your EPC/X system is com-
7
plete. However, since the EPC/X adapter and the EPC/CON-16 concen-
trators must have software downloaded to their internal RAM before they
8
become functional, you must next install the software drivers for your
20
operating system.
22
Read the instruction booklet for the CD-ROM that came with your
system for instructions on installing software.
View the on-line documentation on the CD-ROM for more informa-
tion about your EPC/X system.
The Digi logo and AccelePort are registered trademarks of Digi International. EPC/X,
EPC/CON-16, PORTS/Xem PORTS/8em, PORTS/16em, Modem/Xem, Modem/4em, and
Modem/8em are trademarks of Digi International.
All other brand and product names are trademarks of their respective holders.
© Digi International Inc., 1998; All Rights Reserved; http://www.dgii.com
Information in this document is subject to change without notice and does not represent a
commitment on the part of Digi International.
Digi provides this document "as is", without warranty of any kind, either expressed or
implied, including, but not limited to, the implied warranties of fitness or merchantability
for a particular purpose. Digi may make improvements and/or changes in this manual or in
the product(s) and/or the program(s) described in this manual at any time.
This product could include technical inaccuracies or typographical errors. Changes are peri-
odically made to the information herein; these changes may be incorporated in new editions
of the publication.
Description
Pin
RI
Ring Indicator
1
Data Set Ready
2†
Request To Send
3
Chassis Ground
4
Transmitted Data
5
Received Data
6
SG
Signal Ground
7
Clear To Send
8
Data Terminal Ready
9
Data Carrier Detect
10
connector
91000749 A
AccelePort
EPC/CON-16 Concentrator
Installation Guide
Introduction
®
An AccelePort
EPC/X
system consists of an EPC/X host adapter cou-
pled with EPC/CON-16
concentrators from which EIA-232 peripheral
devices such as printers, terminals or modems can be cabled and con-
trolled. The adapter has two lines that can each support one or more con-
centrators. Multiple concentrators can be linked in a chain, and Digi
PORTS/8em
, PORTS/16em
, Modem/4em
modules can be added to a concentrator to expand the number of ports
available.
Figure 44.
Example EPC/X setup
This installation guide describes how to plan your setup and install the
EPC/X host adapter and concentrator hardware.
EPC/X System
EPC/X PCI Host Adapter
Hardware
, and/or Modem/8em

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACCELEPORT EPC/CON-16 and is the answer not in the manual?

Questions and answers

Summary of Contents for Digi ACCELEPORT EPC/CON-16

  • Page 1 Digi may make improvements and/or changes in this manual or in the product(s) and/or the program(s) described in this manual at any time.
  • Page 2 30 feet (9 meters). You can also use fiber optic cable (a special fiber optic conversion option is available from Digi) that will allow a distance of up to 1.2 miles (2000 meters) from the adapter. For even greater distances, you can attach a synchronous modem directly to the adapter, and remotely locate concentrators and Xem modules to a second synchronous modem.

This manual is also suitable for:

Acceleport epc/x

Table of Contents