PCD300IL INSTALLATION,
OPERATION, AND MAINTENANCE MANUAL
INTRODUCTION
DO NOT INSTALL, USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND UNDERSTOOD. READ AND SAVE
THESE INSTRUCTIONS FOR FUTURE USE.
These instructions are intended to supplement sound installation practices and are not intended to cover detailed instruction procedures
because of the wide variety of fan types and field conditions that exist.
It is the responsibility of the purchaser to assure that the installation and maintenance of this equipment is handled by qualified personnel
experienced in such work and equipment.
Contact your local representative should you need further information.
SAFETY INFORMATION
WARNING! To reduce the risk of fire, electric shock, or injury to persons, observe the following:.
a. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being
switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.
c. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
d. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
e. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling
installation only).
g. Acceptable for use over a tub or shower when connected to a GFCI (ground fault circuit interrupter)—protected branch circuit (ceiling
installation only).
h. This unit must be grounded.
i. Not for use in kitchens.
j. To reduce risk of fire and to properly exhaust air, be sure to duct air outside—do not vent exhaust air into spaces within walls/ceilings or into
attics, crawl spaces, or garages.
k. WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
l. The fan must not be installed in a ceiling thermally insulated to a value greater than R40.
S & P V E N T I L AT I O N SYS T E M S
S o l er Pal a u- USA . co m | S o l erPa l a uC a n a d a .c o m
®

Advertisement

loading
Need help?

Need help?

Do you have a question about the PCD300IL and is the answer not in the manual?

Questions and answers

Summary of Contents for S&P PCD300IL

  • Page 1 ® S & P V E N T I L AT I O N SYS T E M S PCD300IL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL S o l er Pal a u- USA . co m | S o l erPa l a uC a n a d a .c o m INTRODUCTION DO NOT INSTALL, USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND UNDERSTOOD.
  • Page 2 CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. This product is designed for installation in ceilings up to a 12/12 pitch (45° angle). Duct connector must point up. 3. If the ventilator is installed in an unconditioned space (such as an attic): surround the ventilator with thermal insulation—to minimize possible condensation.
  • Page 3 WASHER RUBBER 1 2. Mount with Hanger Bracket: Before installation, need to assembly hanger bracket and rubber 3 to housing with screw. Then install the rubber 1, rubber 2 and washer to hanger bracket. RUBBER 2 Use anchor bolts (not included) to secure housing. WASHER RUBBER SCREW...
  • Page 4 “Electrical Wiring” section of this manual. Adjustable High-Speed Settings · Model PCD300IL: Toggle switches offer four selectable high-speed settings. These represent approximate airflow values. For detailed airflow vs static pressure performance, please refer to the product submittal.
  • Page 5 Two Speed Operation: 1. Low-Speed for Continuous Operation: The fan operates continuously at a lower speed (≥40 CFM), Adjust the low-speed continuous airflow using the “Low Airflow Knob” (Range: 40 CFM to high-speed setting). 2. High-Speed for On-Demand Operation: Set the desired high- speed airflow using the toggle switches in the control box.
  • Page 6 PCD300IL INSTALLATION, FONC TIONNEMENT E T ENTRE TIEN INTRODUCTION N’INSTALLEZ PAS, N’UTILISEZ PAS OU N’UTILISEZ PAS CET ÉQUIPEMENT AVANT D’AVOIR LU ET COMPRIS CE MANUEL. LISEZ ET CONSERVEZ CES INSTRUCTIONS POUR UNE UTILISATION ULTÉRIEURE. Ces instructions visent à compléter les saines pratiques d’installation et ne visent pas à couvrir les procédures d’instruction détaillées en raison de la grande variété...
  • Page 7 PLANIFIEZ L’INSTALLATION INSULATION* ROOF CAP* Installation en tant que ventilateur d’extraction en ligne Place around and over with built-in damper fan housing Plage de température de fonctionnement : ce ventilateur est conçu pour fonctionner dans une plage de température comprise entre -10 HOUSING °C (14 °F) et 40 °C (104 °F).
  • Page 8 4. Installation de l’alimentation en air en ligne avec filtre en option : Lors de l’installation du ventilateur pour des applications d’alimentation en air en ligne, un filtre à air en option peut être ajouté pour assurer la filtration à l’entrée d’air. Dimensions du filtre: 9 ¾"...
  • Page 9 Réglages de vitesse élevée · Modèle PCD300IL : les commutateurs à bascule offrent quatre réglages de vitesse élevée sélectionnables. Ceux-ci représentent des valeurs approximatives de débit d’air. Pour connaître les performances détaillées en termes de débit d’air et de pression statique, veuillez vous reporter à...
  • Page 10 Fonctionnement à deux vitesses: 1. Faible vitesse pour un fonctionnement continu : le ventilateur fonctionne en continu à une vitesse réduite (≥ 40 CFM). Réglez le débit d’air continu à faible vitesse à l’aide du « bouton de débit d’air faible » (plage : 40 CFM à réglage haute vitesse). 2.
  • Page 11 S&P VENTILATION SYSTEMS Enab ling the World t o Bre athe B et ter Air ® S&P USA VENTIL ATION SYSTEMS, LLC S&P CANADA VENTILATION PRODUCTS, INC. 6393 Powers Avenue 6710 Maritz Drive, Unit 7 Jacksonville, FL 32217 Mississauga, ON L5W 0A1, Canada SolerPalau-USA.com SolerPalauCanada.com 800.961.7370...