COMPONENTS
RELAY 3
BLOWER MOTOR
(Wire leads removed)
STIRRER
MOTOR
(Wire leads removed)
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
TEST PROCEDURE
Check for continuity of relay 3 an
ohm-meter.
(Remove wire leads from relay 3 and
operate the unit.)
Relay 3
Measure the resistance.
(Ohm-meter scale: R x 100)
Measure the resistance.
(Ohm-meter scale: R x 1000)
5-10
RESULTS
POWER
LEVEL
1
3 sec
2
4 sec
3
5 sec
4
6 sec
5
7 sec
6
8 sec
7
9 sec
8
10 sec
9
11 sec
10
12 sec
Normal: Approx. 14~21 ohm
Abnormal: Infinite or several
K-ohm.
Normal: Approx. 3~3.5 kohm
Abnormal: Infinite or several
ohm.
9 sec
8 sec
7 sec
6 sec
7 sec
4 sec
3 sec
2 sec
1 sec
0 sec