Ortech ODDE-70 Installation Instructions Manual

Ventilation fan

Advertisement

MODEL: ODDE-70
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent
power from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off
power unit.
4. Please read specification label on product for further information and requirements.
Do not use in a cooking area.
5.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noi-
ses, replace the motor with the exact service motor. The impeller should also be replaced.
OPERATION
Use an on/off switch to operate this fan. See "Connect Wiring" for details.
PLAN THE INSTALLATION
1. Do not use in a cooking area.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
Cod:0060304632-A
VENTILATION FAN
2. Two ways to connect ductwork to a factory-shipped unit.
INSULATION*
(Place around and
over Fan Housing.)
FAN
POWER
HOUSING
CABLE*
Seal gaps
around
Housing.
ROUND
DUCT*
Seal duct
*
Purchase
joints with
ELBOW(S) *
separately
tape.
1
ROOF CAP*
(with built-in
damper)
Keep duct
runs short
WALL CAP*
(with built-in
ROUND
damper)
www.ortechindustries.ca

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ODDE-70 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ortech ODDE-70

  • Page 1 VENTILATION FAN MODEL: ODDE-70 WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  • Page 2 REPLACE THE INSTALLATION REMOVE THE EXISTING FAN 1.Ensure the existing fan opening is smaller than the new fan.(Fig.1) CAUTION Fig.1 Switched off the power to your existing fan before installation, 2.Using a pencil, score the ceiling along the housing of the new fan,then cut the new opening in the ceiling using a drywall saw.(Fig.2) Fig.2 CAUTION...
  • Page 3: New Installation

    ASSEMBLY INSTRUCTIONS 2.Pull existing ducting through the ceiling opening. Secure existing duct to the fan's duct connector,Ensure that the fan's damper is unobstructed and free to swivel freely,using tape (not included), secure all the ductwork connections so that they are air tight.(Fig.7) Fig.7 3.Secure the fan housing to the ceiling joist with screws.(Fig.8)
  • Page 4: Connect Electrical Wiring

    Screw Circlip ODDE-50ES ODDE-70 WARRANTY FIVE YEAR LIMITED WARRANTY from the original date of purchase against defects in material and workmanship. This warranty is limited up to the amount of the original purchase price of the product, excluding any labor cost. For inquiries please visit www.ortechindustries.ca or call 1-888-543-6473.
  • Page 5 MODÈLE: ODDE-70 PLANIFIE VOTRE INSTALLATION...