Download Print this page

Hinen B8900M-HA User Manual

Rechargeable li-ion battery system

Advertisement

Quick Links

Dongguan Hinen New Energy Technology Co., Ltd
Add: No.�� Dongkang Road, Dalingshan Town,
Dongguang City, Guangdong, China
Email: service@hinen.com
Tel: +�� (���) �������� ext ����
Website: https://www.hinen.com
Hinen Australia Pty. Ltd.
Add: Suite ���,Level �, Tenancy �,��� Mount Street, North Sydney
Email: service@hinen.com.au
Tel: +�� � ���� ����
Website: https://au.hinen.com
Europe
HL Hinen B.V.
Add: John M. Keynesplein �, ����EP Amsterdam
Email: service@hinen.com
Tel: +�� (���) �������� ext ����
Website: https://nl.hinen.com
Hinen Energy Eastern Europe
Add: Wąska 95, 05-806 Sokołów Poland
Email: biuro@hinen.com
Tel: +48 606 807 712
Website: https://pl.hinen.com
Hinen South Africa (Pty) Ltd
Add:Ground floor, Block B, ��� West Street,
Sandton.Johannesburg ����, South Africa
Email: SAfrica@hinen.com
Tel: +�� �� ��� ����
Website: https://za.hinen.com
Hinen Technology East Africa LIMITED
Add: No. �, Kirichwa Lane Court, next to
GreenhouseMall, Ngong Road, Nairobi, Kenya
Email: EAfrica@hinen.com
Tel: +������������
Website: https://ke.hinen.com
Hinen West Africa LIMITED
Add: ��A-� Talabi St, Ogba, Lagos ������, Lagos, Nigeria
Email: WAfrica@hinen.com
Tel: +�� (���) �������� ext ����
Website: https://ng.hinen.com
RECHARGEABLE LI-ION
BATTERY SYSTEM
�.�-��.�kWh
User Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the B8900M-HA and is the answer not in the manual?

Questions and answers

Summary of Contents for Hinen B8900M-HA

  • Page 1 RECHARGEABLE LI-ION BATTERY SYSTEM Dongguan Hinen New Energy Technology Co., Ltd Add: No.�� Dongkang Road, Dalingshan Town, �.�-��.�kWh Dongguang City, Guangdong, China Email: service@hinen.com Tel: +�� (���) �������� ext ���� Website: https://www.hinen.com Hinen Australia Pty. Ltd. Add: Suite ���,Level �, Tenancy �,��� Mount Street, North Sydney Email: service@hinen.com.au...
  • Page 2 Notice The contents of this document may be updated from time to time due to product version upgrades or for other reasons. If not otherwise agreed, the contents of this document do not replace the safety precautions on the product labels or in the user manual. All descriptions in this document are intended as a guide to use only. Contents �...
  • Page 3 � Forward � Safety precautions This document primarily provides an overview of the battery system, covering aspects such as product details, This document contains information on safety precautions that must be followed when operating the installation procedures, wiring, configuration, testing, troubleshooting, and maintenance. Please read this equipment.
  • Page 4 �.� Battery safety Symbol definition Potential hazards exist when the Danger equipment is operating. Please take The equipment should be kept away precautions when operating equip- from open flames or sources of ignition. ment. �. The battery system operates at hazardous voltage. Before operating the equipment in the system, make sure that the equipment is disconnected from the power supply to avoid the risk of electric shock.
  • Page 5 Fire �.� Application scenarios · When the battery temperature exceeds ���°C, the battery is at risk of fire, and the battery may release toxic and harmful gases if it catches fire. Note · To avoid a fire, make sure there is a carbon dioxide, Novac ���� or FM-��� fire extinguisher near the unit. ·...
  • Page 6 �.� Appearance description � Equipment inspection and storage � �.� Check before signing Before signing for the product, please check the following in detail: �. Inspect the outer packaging for any signs of damage, including deformation, holes, cracks, or other indicators that could potentially harm the equipment inside.
  • Page 7 �.� Equipment storage If the equipment is not put into immediate use, please store it according to the following requirements: If the equipment is not immediately installed, please ensure the storage environment meets the conditions: �. The equipment should remain in its original packaging, with a desiccant placed inside the box before sealing. �.
  • Page 8 �.� Installation Clearance Requirements �.� Handling equipment Reserve enough clearance around the battery to ensure sufficient space for airflow and heat dissipation. Caution �. During transportation, handling, installation, and other related operations, it is essential to adhere to the laws, regulations, and applicable standards of the respective country and region. �.
  • Page 9 Base installation (without foot pad bolts) Base installation (with foot pad bolts) Step �: Install two foot pad screws on the back of the base. (The foot pad screws can control the appropriate Step �: Install two foot pad screws on the back of the base. (The foot pad screws can control the appropriate distance between the product and the wall.) distance between the product and the wall.) Step �: Install the adjustable foot pad bolts to the base.
  • Page 10 Battery module installation Step �: Lock the wall-locking bracket to the battery and the wall with two expansion bolts and two M�*��mm screws. � Before stacking the batteries, make sure to remove the protective covers from the top socket and bottom plug of the battery. �...
  • Page 11 BMS control unit installation Step �: Remove the slot for wire outlet on thecontrol box side cover. (Note: When used with an all-in-one inverter, remove the top slot; when used individually, remove the side slot.) Step �: After completing the wiring, install the control box side cover. (Refer to the wiring section for details.) Step �: Before connection, remove both protective covers from the battery and the BMS control unit.
  • Page 12 �.� Electrical connection � Electrical connection Single battery system �.� Safety precautions Note Danger �. The positive terminal of the battery, labeled BAT+, should be connected to the inverter's BAT+ terminal, while the negative terminal, labeled BAT-, must be connected to the inverter's BAT- terminal. Ensure that these connections are correct.
  • Page 13 Note �-� parallel cluster battery system Single Cluster Battery System �. This wiring method is suitable for �-� cluster parallel battery systems. BAT+ �. The positive terminal of the battery, labeled BAT+, Note should be connected to the inverter's BAT+ terminal, and the negative terminal, labeled BAT-, must be �.
  • Page 14 Note �-� parallel cluster battery system �.� Protective ground wire connection �. This wiring method is suitable for �-� cluster parallel battery systems. Note BAT+ �. The positive terminal of the battery, labeled BAT+, should be connected to the inverter's BAT+ terminal, and �.
  • Page 15 �.� Communication cable connection COM. OUT interface definition RJ�� PIN Definition Remark Warning WAKE UP �. If the inverter model you have comes with a communication cable connecting the inverter to the battery, you can decide whether to use the provided cable based on specific circumstances. For detailed cable specifications, please refer to the user manual for the relevant inverter model.
  • Page 16 �.� Battery system power-up � System operation �.� Check before powering on Warning �. The dotted box is an optional configuration. When powering up the battery system, be sure to check the following to prevent system �. The circuit breaker between the inverter and the battery, as well as the circuit breaker within the battery damage.
  • Page 17 Tap the inverter connected with battery to enter the corresponding interface and check the battery parameter. After connecting the battery and inverter, use the Hinen App to select the appropriate options for parameter viewing and configuration. · APP Installation and Connection: Method �:...
  • Page 18 Blue light �: running light Indicator light Condition The battery is compatible with A����S, A�����S, A�����T and H�����T series. Please choose HINEN Blue light � The battery SOC indicator light displays the current battery capacity. protocol and click “Save” .
  • Page 19 �.� Regular maintenance � Maintenance Warning �.� Battery system power-down �. If you encounter any issues that could impact the battery or energy storage inverter system, please contact the after-sales team. Unauthorized disassembly is prohibited. �. If you notice any exposed copper wiring in the conductive wire, do not touch it due to hazardous voltage Danger risks.
  • Page 20 �.� Troubleshooting Error Code Inverter State Fault category Solution �. Charge the battery. In the event of a battery system failure, the system may automatically shut down or experience abnormal Battery pack discharge Error ��� BAT Error/Off functions. To address this issue, please follow the troubleshooting methods outlined below. If the issue persists �.
  • Page 21 Fault indicator light status Warning: The blue running light is off and the red light is on. Status Status Status Light Light Light Warning: The blue running light is off and the red light is flashing. Solution Solution Solution Description Description Description Display...
  • Page 22 � Technical Specification Overcurrent protection Overtemperature/under- �.� Standard Battery System temperature protection DC circuit breaker Product name Rechargeable Li-ion Battery System Shutdown current Battery system model B����M-HA B����M-HB B����M-HC General Data Number of battery � module � modules � modules modules Communication B����M-HP...
  • Page 23 �.� Battery System With Heating Function Overcurrent protection Overtemperature/under- Product name Rechargeable Li-ion Battery System temperature protection DC circuit breaker Battery system model B����M-HAW B����M-HBW B����M-HCW Shutdown current Number of battery � module � modules � modules modules General Data B����M-HPW BMS control unit model System Data...

This manual is also suitable for:

B8900m-hbB8900m-hcB8900m-hawB8900m-hbwB8900m-hcw