Document # PG12-003
B
B
F
D
G
I
F
N
J
G
L
I
N
J
L
P
P
CUTOUT DIMENsIONs
120 Vac power cord
120 Vac power cord
F
F
A. 28 5/16"
D. 23 3/8"
B. 4 11/16"
E. 30"
C. 2"
F. 15 5/8"
OVERALL DIMENsIONs
A. 28 5/16"
D. 23 3/8"
B. 4 11/16"
E. 30"
C. 2"
F. 15 5/8"
www.Dacor.com
Phone: (800) 793-0093
MMD30, MMDV30
30" Microwave In-A-Drawer
A
C
A
D
E
C
E
H
K
Q
I
H
K
M
Q
I
M
O
Electrical outlet
location
O
48" (1219mm)
3-prong
48" (1219mm)
A
B
3-prong
C
A
B
C
E
G. 15 1/16"
H. 1" door thickness
I. 15 1/4" auto drawer opening
E
G. 15 1/16"
H. 1" door thickness
I. 15 1/4" auto drawer opening
Dedicated Circuit Required
120 Vac, 60 Hz, 15 Amp. 3-wire
grounded, electrical outlet
ELECTRICAL sPECIfICATIONs
A. 6"
B. Electrical outlet location
All tolerances: +1/16", -0, (+1.6mm, -0) unless otherwise stated
C. Anti-tip block
A. 6"
D. 5"
B. Electrical outlet location
E. 3 1/2"
C. Anti-tip block
F. 4"
D. 5"
G. 28 1/2" opening
H. 14 3/4" to bottom of anti-tip block
E. 3 1/2"
I. Allow 3/4" minimum overlap
F. 4"
J. 23 1/2" minimum depth
G. 28 1/2" opening
K. Allow 1/4" minimum overlap
H. 14 3/4" to bottom of anti-tip block
L. 36" nominal countertop height
I. Allow 3/4" minimum overlap
M. Allow 7/16" minimum overlap
J. 23 1/2" minimum depth
N. Floor must support 100 lbs. minimum
K. Allow 1/4" minimum overlap
O. 19" to top of floor (recommended)
L. 36" nominal countertop height
P. 30" cabinet minimum
M. Allow 7/16" minimum overlap
Q. 15 3/16" ± 1/16" opening
N. Floor must support 100 lbs. minimum
NOTE: Open top cabinet illustrated
O. 19" to top of floor (recommended)
P. 30" cabinet minimum
Q. 15 3/16" ± 1/16" opening
NOTE: Open top cabinet illustrated
4"
G
I
D
G
I
H
D
H
Total Connected Load
13 Amp. @ 120 Vac, 60 Hz
Specifications are subject to change without notice.
See installation instructions for additional details.
™
wARNiNg
◊
Observe all governing codes and ordinances
during planning and installation. Contact
your local building department for further
information.
◊
This appliance must be installed in accordance
with the accompanying installation instructions.
5"
ANTI-TIP BLOCK LOCATION
Electrical outlet
location
ELECTRICAL UTILITY LOCATION
NOTES:
1.
Spacing between appliances
and doors/drawers is minimum
required to allow for ventilation
and to prevent scraping.
Additional space may be required
for appearance.
Revised 04/06/09 Page 1/1
PLANNING
GUIDE
(6")
Anti-tip
block
5"
4"
12.6
Need help?
Do you have a question about the MMD24 and is the answer not in the manual?
Questions and answers