Advertisement

Document # PG12-003
B
B
F
D
G
I
F
N
J
G
L
I
N
J
L
P
P

CUTOUT DIMENsIONs

120 Vac power cord
120 Vac power cord
F
F
A. 28 5/16"
D. 23 3/8"
B. 4 11/16"
E. 30"
C. 2"
F. 15 5/8"

OVERALL DIMENsIONs

A. 28 5/16"
D. 23 3/8"
B. 4 11/16"
E. 30"
C. 2"
F. 15 5/8"
www.Dacor.com
Phone: (800) 793-0093
MMD30, MMDV30
30" Microwave In-A-Drawer
A
C
A
D
E
C
E
H
K
Q
I
H
K
M
Q
I
M
O
Electrical outlet
location
O
48" (1219mm)
3-prong
48" (1219mm)
A
B
3-prong
C
A
B
C
E
G. 15 1/16"
H. 1" door thickness
I. 15 1/4" auto drawer opening
E
G. 15 1/16"
H. 1" door thickness
I. 15 1/4" auto drawer opening
Dedicated Circuit Required
120 Vac, 60 Hz, 15 Amp. 3-wire
grounded, electrical outlet

ELECTRICAL sPECIfICATIONs

A. 6"
B. Electrical outlet location
All tolerances: +1/16", -0, (+1.6mm, -0) unless otherwise stated
C. Anti-tip block
A. 6"
D. 5"
B. Electrical outlet location
E. 3 1/2"
C. Anti-tip block
F. 4"
D. 5"
G. 28 1/2" opening
H. 14 3/4" to bottom of anti-tip block
E. 3 1/2"
I. Allow 3/4" minimum overlap
F. 4"
J. 23 1/2" minimum depth
G. 28 1/2" opening
K. Allow 1/4" minimum overlap
H. 14 3/4" to bottom of anti-tip block
L. 36" nominal countertop height
I. Allow 3/4" minimum overlap
M. Allow 7/16" minimum overlap
J. 23 1/2" minimum depth
N. Floor must support 100 lbs. minimum
K. Allow 1/4" minimum overlap
O. 19" to top of floor (recommended)
L. 36" nominal countertop height
P. 30" cabinet minimum
M. Allow 7/16" minimum overlap
Q. 15 3/16" ± 1/16" opening
N. Floor must support 100 lbs. minimum
NOTE: Open top cabinet illustrated
O. 19" to top of floor (recommended)
P. 30" cabinet minimum
Q. 15 3/16" ± 1/16" opening
NOTE: Open top cabinet illustrated
4"
G
I
D
G
I
H
D
H
Total Connected Load
13 Amp. @ 120 Vac, 60 Hz
Specifications are subject to change without notice.
See installation instructions for additional details.
wARNiNg
Observe all governing codes and ordinances
during planning and installation. Contact
your local building department for further
information.
This appliance must be installed in accordance
with the accompanying installation instructions.
5"

ANTI-TIP BLOCK LOCATION

Electrical outlet
location

ELECTRICAL UTILITY LOCATION

NOTES:

1.
Spacing between appliances
and doors/drawers is minimum
required to allow for ventilation
and to prevent scraping.
Additional space may be required
for appearance.
Revised 04/06/09 Page 1/1
PLANNING
GUIDE
(6")
Anti-tip
block
5"
4"
12.6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MMD24 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

In-a-drawer mmd30In-a-drawer mmdv30

Table of Contents