Toshiba MMK-AP0073HP-E1 Owner's Manual
Toshiba MMK-AP0073HP-E1 Owner's Manual

Toshiba MMK-AP0073HP-E1 Owner's Manual

Super modular multi system air conditioner

Advertisement

Quick Links

SUPER MODULAR MULTI SYSTEM AIR CONDITIONER
Owner's Manual
For wireless remote controller
1111058598
Indoor Unit
Model name:
For commercial use
High-Wall Type
MMK-AP0073H, MMK-AP0073HP-E1, MMK-AP0073H1, MMK-AP0073HP1-E1
MMK-AP0093H, MMK-AP0093HP-E1, MMK-AP0093H1, MMK-AP0093HP1-E1
MMK-AP0123H, MMK-AP0123HP-E1, MMK-AP0123H1, MMK-AP0123HP1-E1
MMK-AP0153H, MMK-AP0153HP-E1, MMK-AP0153H1, MMK-AP0153HP1-E1
MMK-AP0183H, MMK-AP0183HP-E1, MMK-AP0183H1, MMK-AP0183HP1-E1
MMK-AP0243H, MMK-AP0243HP-E1, MMK-AP0243H1, MMK-AP0243HP1-E1
English
Owner's Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MMK-AP0073HP-E1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Toshiba MMK-AP0073HP-E1

  • Page 1 Owner’s Manual For wireless remote controller 1111058598 Indoor Unit Model name: For commercial use High-Wall Type MMK-AP0073H, MMK-AP0073HP-E1, MMK-AP0073H1, MMK-AP0073HP1-E1 MMK-AP0093H, MMK-AP0093HP-E1, MMK-AP0093H1, MMK-AP0093HP1-E1 MMK-AP0123H, MMK-AP0123HP-E1, MMK-AP0123H1, MMK-AP0123HP1-E1 MMK-AP0153H, MMK-AP0153HP-E1, MMK-AP0153H1, MMK-AP0153HP1-E1 MMK-AP0183H, MMK-AP0183HP-E1, MMK-AP0183H1, MMK-AP0183HP1-E1 MMK-AP0243H, MMK-AP0243HP-E1, MMK-AP0243H1, MMK-AP0243HP1-E1 English...
  • Page 2 Owner’s Manual SMMS High-Wall Type Thank you very much for purchasing TOSHIBA Air Conditioner. Please read this owner’s manual carefully before using your Air Conditioner. Be sure to obtain the “Owner’s manual” and “Installation manual” from constructor (or dealer). Request to constructor or dealer Please clearly explain the contents of the Owner’s manual and hand over it.
  • Page 3: Table Of Contents

    Owner’s Manual SMMS High-Wall Type Contents PRECAUTIONS FOR SAFETY ........5 ACCESSORIES .
  • Page 4 Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work.
  • Page 5 Owner’s Manual SMMS High-Wall Type Warning indications on the air conditioner unit ■ Warning indication Description WARNING WARNING ELECTRICAL SHOCK HAZARD ELECTRICAL SHOCK HAZARD Disconnect all remote electric power supplies Disconnect all remote electric power supplies before servicing. before servicing. WARNING WARNING Moving parts.
  • Page 6: Precautions For Safety

    Owner’s Manual SMMS High-Wall Type PRECAUTIONS FOR SAFETY DANGER • Do not attempt to install this unit by yourself. This unit requires qualifi ed installer. • Do not attempt to repair the unit by yourself. This unit has no components which you can repair. •...
  • Page 7: Installation

    Owner’s Manual SMMS High-Wall Type • The air conditioner must be transported in stable condition. If any part of the product broken, contact your dealer. • When the air conditioner must be transported by hand, carry it by two or more people.
  • Page 8 Owner’s Manual SMMS High-Wall Type • Use of a stand more than 50 cm high to clean the fi lter of the indoor unit or to carry out other such jobs constitutes working at heights. Due to the danger of falling off the stand and injuring yourself while working at heights, this kind of work should not be done by unqualifi...
  • Page 9 Owner’s Manual SMMS High-Wall Type • If there is a danger of the indoor unit’s falling, do not approach the indoor unit but set the circuit breaker to the OFF position, and contact a qualifi ed installer(*1) or a qualifi ed service person(*1) to refi t the unit. Do not set the circuit breaker to the ON position until the unit has been refi...
  • Page 10 Owner’s Manual SMMS High-Wall Type • Check whether the installation base and other equipment have become deteriorated after being used for a long time. Leaving them such condition may result in the unit’s falling down and causing injury. • Do not leave fl ammable sprays or other fl ammable materials near the air conditioner, and do not spray fl...
  • Page 11 Owner’s Manual SMMS High-Wall Type Information on the transportation, handling and storage of the carton ■ ◆ Examples of indication on the carton Symbol Description Symbol Description Keep dry Do not drop Fragile Do not lay down Stacking height 11 cartons (12 cartons can be stacked Do not walk on this carton in this case)
  • Page 12: Accessories

    Owner’s Manual SMMS High-Wall Type ACCESSORIES Remote controller Remote controller holder Batteries (two) PARTS NAME Indoor unit TIMER SET MODE TIME SAVE VENT FILTER RESET TEST SWING/FIX UNIT LOUVER 8, 9 Room temperature sensor Horizontal airflow louver Front panel Vertical airflow louver Air inlet grille Display panel Air filter...
  • Page 13: Names And Functions Of Indicators And Controls On Indoor Unit

    Owner’s Manual SMMS High-Wall Type Names and functions of CAUTION indicators and controls on indoor unit Disagreement in operation mode If you select AUTOMATIC OPERATION in a model with no auto-changeover (cooling/ Display panel heating) control setting or if you select HEAT in a Cool Only model, an alarm sound (pi, pi) from the air conditioner due to disagreement in operation mode.
  • Page 14: Parts Name Of Remote Controller

    Owner’s Manual SMMS High-Wall Type PARTS NAME OF REMOTE CONTROLLER Wireless remote controller and You can also manually select the desired fan speed from among five settings. its functions (LOW , LOW , MED , HIGH (A receiving beep is heard.) Auto louver button (SWING) Press this button to swing the louver.
  • Page 15: Names And Functions Of Indications On Wireless Remote Controller

    Owner’s Manual SMMS High-Wall Type Names and functions of (COMFORT SLEEP) display Indicated during the OFF timer operation that indications on wireless remote automatically adjusts the room temperature and the controller fan speed. Each time you press the COMFORT SLEEP button, the display changes in the sequence of 1h, 3h, 5h, and 9h.
  • Page 16: Adjusting Clock

    Owner’s Manual SMMS High-Wall Type ADJUSTING CLOCK Clock adjusting Setting the clock Before you start operating the air conditioner, set the clock of the remote controller using the procedures given in this section. The clock panel on the remote controller will indicate the time regardless of whether the air conditioner is in use or not.
  • Page 17: Limited Operation By Group Control

    Owner’s Manual SMMS High-Wall Type LIMITED OPERATION BY GROUP CONTROL NOTE Group control: Operate air conditioners in more than one system in same time. Header indoor unit: The representative unit during group control. Receive commands from wired remote controller and transmit the commands to follower units. (Header indoor unit is indoor unit that receives START/STOP signal from the wireless remote control.) Follower indoor unit: Indoor units other than the Header unit are called follower unit.
  • Page 18: Handling The Remote Controller

    Owner’s Manual SMMS High-Wall Type HANDLING THE REMOTE CONTROLLER Remote controller holder CAUTION Installing the remote controller holder • The air conditioner will not operate if curtains, • Before you actually install the remote controller doors or other materials block the signals from holder on a wall or pillar, check whether the the remote controller to the indoor unit.
  • Page 19: How To Use Remote Controller

    Owner’s Manual SMMS High-Wall Type HOW TO USE REMOTE CONTROLLER Cooling/heating/fan only Dry operation operation Start Start PRESET TEMP PRESET TEMP MODE MODE START/STOP button ( Press this button to start the air conditioner. START/STOP button ( Mode select button (MODE) Press this button to start the air conditioner.
  • Page 20: Automatic Operation (Auto Changeover)

    Owner’s Manual SMMS High-Wall Type Automatic operation Timer operation (auto changeover) Use the wired remote controller for timer setting if it is also in use. This function is available only for use in combination with a heat recovery model outdoor ON timer and OFF timer unit.
  • Page 21: Clock Display

    Owner’s Manual SMMS High-Wall Type ON timer —> OFF timer Once you select the timer operation mode, the settings are saved in the remote controller. (Stop —> Operation —> Stop) Thereafter, the air conditioner will start operating You can use this setting to start the air conditioner under the same conditions when you simply press when you wake up and stop it when you leave the the ON/OFF button of the remote controller.
  • Page 22: High Power Operation

    Owner’s Manual SMMS High-Wall Type High power operation Quiet operation • The QUIET mode provides quiet operating High power (Hi POWER) status by automatically setting the fan speed to • The Hi POWER (high power operation) mode the lowest speed. automatically controls room temperature, airflow and operation mode so that the room is quickly cooled in summer and warmed in winter.
  • Page 23: Preset Operation

    Owner’s Manual SMMS High-Wall Type Preset Operation CAUTION Set your preferred operation mode for future use. The COMFORT SLEEP mode is not enabled in The setting is memorized by the unit for future DRY or FAN ONLY operation. operation (except airflow direction). NOTE •...
  • Page 24: Adjusting Air Flow Direction

    Owner’s Manual SMMS High-Wall Type Adjusting airflow direction To automatically swing the airflow direction • Adjust the airflow direction properly. Otherwise, it Perform this function when the air conditioner is in might cause discomfort and make the room operation. temperature uneven. •...
  • Page 25 Owner’s Manual SMMS High-Wall Type CAUTION • The FIX and SWING buttons will be disabled when the air conditioner is not in operation (including when the ON timer is set). • Do not operate the air conditioner for long hours with the airflow direction set downward during the cooling or dry operation.
  • Page 26: Hints For Economical Operation

    Owner’s Manual SMMS High-Wall Type HINTS FOR ECONOMICAL OPERATION Maintain room temperature at comfortable level Clean air filters The clogged air filters impairs the performance of the air conditioner. Clean them once two weeks. Never open doors and windows more Gee, chilly often than necessary Control...
  • Page 27: Temporary Operation

    Owner’s Manual SMMS High-Wall Type TEMPORARY OPERATION TEMPORARY operation This function is used to operate the unit temporarily in case you misplace the wireless remote controller or its batteries are exhausted. • Push the button once (less than 3 seconds) to start the air conditioner. •...
  • Page 28: Maintenance

    Owner’s Manual SMMS High-Wall Type MAINTENANCE WARNING Before you clean the air conditioner, be sure to turn off the circuit breaker or main power switch. Cleaning of indoor unit and remote controller CAUTION • Use a dry cloth to wipe the indoor unit and remote controller. •...
  • Page 29: Cleaning The Air Filter

    Owner’s Manual SMMS High-Wall Type Cleaning the air filter 4. Insert the upper portion of air filter confirming to fit its right and left edges on the indoor unit until it is firmly set. Clean the air filters every 2 weeks. If the air filters are covered with dust, the performance of the air conditioner will deteriorate.
  • Page 30 Owner’s Manual SMMS High-Wall Type 3. Wipe out water from the air inlet grille and dry it. 4. Fit the left and right arms of the air inlet grille to the shafts on the two sides of the air conditioner and push in completely, and then push in the centre arm.
  • Page 31: Troubles And Causes

    Owner’s Manual SMMS High-Wall Type TROUBLES AND CAUSES For contents of the outdoor unit, combinations, etc., refer to the owner’s manual supplied with the outdoor unit. CAUTION If any of the following conditions occur, stop the air conditioner immediately, set to off the main power switch and contact the dealer: •...
  • Page 32 Owner’s Manual SMMS High-Wall Type These are not failures. The back of indoor unit is dewed. • Dewdrops on the back of the indoor unit are automatically collected and drained out. Indoor unit or outdoor unit makes a strange noise. •...
  • Page 33: Specifications

    MMK-AP0183HP1-E1 MMK-AP0243HP1-E1 * Under 70 dBA Declaration of Conformity Manufacturer: TOSHIBA CARRIER (THAILAND) CO., LTD. 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur Muang, Pathumthani 12000, Thailand TCF holder: TOSHIBA CARRIER EUROPE S.A.S Route de Thil 01120 Montluel FRANCE...