This document guides the installer through the complete installation process for the following products:
– Savant Power Storage 20 (PS20-12.5KW-100A-xx) composed of:
Savant Power Inverter (PS-INV-12.5KW-100A-xx)
Savant Power Storage 20 Battery Cabinet (PS20-BATT-ENCL-xx / PS20-BATT-ENCL-LEFT-xx)
Savant Power Storage 20 Battery Modules (PS20-BATT-20KWH-xx)
Copyright © 2025 Savant Systems Inc.
45 Perseverance Way, Hyannis, MA 02601
Savant.com/power
| 508.683.2500

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Power Storage 20 and is the answer not in the manual?

Questions and answers

Summary of Contents for Savant Power Storage 20

  • Page 1 This document guides the installer through the complete installation process for the following products: – Savant Power Storage 20 (PS20-12.5KW-100A-xx) composed of: Savant Power Inverter (PS-INV-12.5KW-100A-xx) Savant Power Storage 20 Battery Cabinet (PS20-BATT-ENCL-xx / PS20-BATT-ENCL-LEFT-xx) Savant Power Storage 20 Battery Modules (PS20-BATT-20KWH-xx) Copyright © 2025 Savant Systems Inc.
  • Page 2: Table Of Contents

    Table of Contents Important Safety Information ..................3 System Commissioning ..................... 38 6.1. Savant Power Storage 20 Commissioning Resources ......38 Before You Begin ......................5 Troubleshooting ......................39 Introduction ........................6 7.1. Savant Power Inverter Status LED Troubleshooting ......39 2.1. Installation Quick Steps ..................7 7.2.
  • Page 3: Important Safety Information

    Safety Statements Before installing, configuring, or operating any equipment, Savant recommends Read this entire document before installing or using Savant Power Storage 20. that each dealer, integrator, installer, etc. access and read all relevant technical Failure to read or follow any of the instructions or warnings in this document documentation.
  • Page 4: Fcc Compliance

    RF Warning Statement The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure conditions without restriction. Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 4 -...
  • Page 5: Before You Begin

    Savant Power Storage Generator Installation and ATS Integration Guide System Commissioning The Savant Power System is commissioned using the Savant Power Storage app while integration with the Savant Power Director occurs through the before the Savant Power and Light App. Create a Savant Power Storage account, then request permissions at support.savant.com/power/s/contactsupport...
  • Page 6: Introduction

    2. Introduction The Savant Power Storage 20 (PS20) is an all-in-one energy solution that acts as a power control system to manage a variety of interconnected power sources alongside an energy storage system to enable energy resiliency in the event of grid disruptions and significant costs savings during every-day operation.
  • Page 7: Installation Quick Steps

    Check and Test System Perform Safety Check......................................................Safety Check Perform First Start Up......................................................System Boot-up Deploy Savant Power Storage System with Savant Power Storage (SPS) App ............................System Commissioning Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc...
  • Page 8: System Specifications

    UL 1741 SA, UL 1741 SB, UL 1741, UL 1741 PCS, Safety UL 1699B, UL 9540, UL 1973, UL 1642, Standards C22.2 No. 107.1 and 330 Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 8 -...
  • Page 9: Connection Requirements

    Rapid Shutdown Devices (RSD) 30 V NOTE: If smaller-size wires and breakers are to be used for AC connection, grid output current can be configured via the Savant Power Storage app. Please contact Savant Support to confirm configurations. Savant Power Storage 20 Installation Guide...
  • Page 10: Voltage And Frequency Ride-Through

    2.4. Voltage and Frequency Ride-through The Savant Power Inverter has voltage and frequency limits for utility interaction according to the following ranges per IEEE 1547:2018 and IEEE 1547.1:2020 Voltage Ride-through Default Settings Ranges of Allowable Settings Voltage Voltage Shall Trip Function (p.u.
  • Page 11: Configuration Types

    Smart Meter Utility Service Rated Disconnect Automated Start Whole Home Generator DC Solar Load Center Optional Optional Savant Power Modules Power Storage 20 Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 11 -...
  • Page 12 Optional Optional Communication Bus Load Center Savant Power Modules Whole Home Generator Optional Power Storage 20 Power Storage 20 Generator Load Combiner* Combiner Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 12 -...
  • Page 13 Communication Bus DC Solar Optional DC Solar Optional Load Center Savant Power Modules Power Storage 20 Whole Home Generator Optional Load Combiner Generator Combiner Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 13 -...
  • Page 14: Installation

    3.1. Installation Location All components of the Savant Power Storage 20 shall be installed in a location that is suitable for use. Installing the system in a manner inconsistent with the guidance given below may void system warranty. The following items should be considered when installing the Savant Power Storage 20: –...
  • Page 15: Mounting The System

    If Inverter is installed with the Battery Cabinet, the bracket for Battery Cabinet, located inside of the accessories kit, is required. NOTE: The maximum recommended conductor distance between Savant Power Inverter and Battery is 100 ft with #8AWG battery conductor wiring.
  • Page 16 Assemble the bracket as shown using M5 flange nuts from the kit. Attach the bracket to the back side of the battery system with the M8x16 screws. Torque: 44 lb-in (5 N*m). Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc...
  • Page 17 Install bracket and Battery Cabinet on the wall, attaching to studs or using wall anchors. Remove the wire closet cover then remove the battery seal cap (BAT/COM) on the bottom of the Savant Power Inverter. Hang the Inverter on the bracket.
  • Page 18 Fasten Inverter and Battery Cabinet with contents from conduit nipple kit and installation kit. Fasten the Inverter and the bracket with the included M5x12 screws. Torque: 26.5 lb-in (3 N*m). Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc...
  • Page 19 Hang Inverter on bracket and fasten with M5x12 screws. NOTE: If installing Inverter on a concrete wall, drill into the wall and attach with wall anchors. Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401...
  • Page 20: Internal Wiring

    RESET USB2 USB3 C-LED UPCS DC 12V RS485-4 RS485-1 NETWORK BCMS BAT- BAT+ DC 12V Figure 2: PS20 Inverter to BCMS Internal Wiring Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 20 -...
  • Page 21: Battery System Installation

    NOTE: Do not install the Battery Access Panel cover on the Battery Cabinet until installation has been completed and the system has been tested for proper function. Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401...
  • Page 22: External Wiring

    100A 600V NOTE: If smaller-size wires and breakers are to be used for AC connection, grid output current can be configured via the Savant Power Storage app. Please contact Savant Support to confirm your configurations. Savant Power Storage 20 Installation Guide...
  • Page 23 NOTE for Parallel Installs with a Generator: When installing AC wire between the upstream breakers in the Gen Combiner Panel to its respective Savant Power Storage 20 GEN input; the combined wire length from the Grid Distribution Panel to the Load Combiner Panel needs to be approximately equal across the PS20 units.
  • Page 24 Wire LOAD connections from Inverter to load. Connect Inverter to a router or Savant Power Director using a CAT5 or higher Ethernet cable. NOTE: Use waterproof port where required. GRID LOAD PV1+ PV1- PV2+ PV2- BAT- BAT+ DC- DC+ P A F G...
  • Page 25 Connect communication port of the AFCI module to the AFCI input of the Savant Power Inverter wiring cabinet. AFCI 10. For systems with connections to AC coupled PV Inverter, and/or multiple parallel applications, see section 3.6. For systems with additional accessories (generator auto-start, E-Stop Button, etc), see Appendix C: Optional Accessories.
  • Page 26: Photovoltaic (Pv) Wiring

    DC coupling provides improved control, efficiency, and system size of connected PV. While solar is not required with any Savant Power Storage 20 System installation, it will provide additional resiliency in the event of a grid outage.
  • Page 27 The PS20 enables easy integration of a grid tied solar installation to enable continued solar production in a grid down scenario. It is recommended to use a UL1741SA compliant inverter when AC coupling into the PS20. Contact Savant Support for design guidance on systems with AC coupled solar.
  • Page 28: Network And Power Director Integration

    3.7. Network and Power Director Integration The Savant Power Director is the controller that enables the full Smart Energy Experience offered by the Savant Power Storage System. The Director acts as the communication hub for the Savant Power Storage 20, Savant Flexible Load Management (FLM) and the Savant app experience. The Savant Power Director and Savant Power Inverter communicate over IP network, thus a local network must be present to integrate the two components together.
  • Page 29: Optional Power Equipment Integration And Wiring

    CONNECTIONS TO GENERATOR Figure 6: PS20 Inverter Generator Connections Use the Savant Power Storage app to program the auto-start and stopping parameters of the connected generator. Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401...
  • Page 30: Parallel And Shared Battery Configurations

    4. Parallel and Shared Battery Configurations The Savant Power Storage 20 can support multi-unit installs with all units operating in parallel to increase the available power and storage for a single site installation. The Appendix provides single line diagrams giving a high level overview of parallel system configurations.
  • Page 31 USB3 C-LED RS485-1 DC 12V NETWORK Network Switch Inverter Connections MAIN NETWORK Figure 8: Standard Parallel Network Connections to Director and Network Switch Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 31 -...
  • Page 32: Shared Battery Parallel Installation

    4.2. Shared Battery Parallel Installation Certain project or site considerations may require two Inverters to a single Power Storage 20 (20 kWh) battery. This configuration gives flexibility to increase the total rated power the system MID can handle, to increase the total installed solar capacity and solar output or to pre-wire for future expansion.
  • Page 33 Multiple Inverter systems, MUST use an AC combiner to connect each Inverter’s GEN port to the AC Coupled solar through appropriately sized breakers. Combine the Load Output of all units at a single location before landing in the backed-up loads panel. Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401...
  • Page 34 14. Follow the instructions in the Savant Power Storage App Setup Guide for guidance on programming for shared battery installations. Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 34 -...
  • Page 35: Safety Check And Basic Operations

    5. Safety Check and Basic Operations CAUTION! Before first boot up and commissioning of the Power Storage 20 System, perform the following safety checks. Failure to perform relevant safety checks could lead to unsafe conditions or system damage. . 5.1. Safety Check...
  • Page 36: System Boot-Up

    8 modules have successfully booted. Once battery has booted, the Savant Power Inverter will begin the boot sequence. Wait until status LED is solid green, the RUN indicator is blinking yellow, and the network LED is solid green.
  • Page 37: System Shut Down

    All LED indicators should turn off. 5.4. System Reboot Under certain circumstances it might be necessary to reboot the Savant Power Storage 20. Follow the instructions below to successfully reboot the system. Shut down Savant Power Storage 20 according to procedure in section 5.3 above.
  • Page 38: System Commissioning

    6.1. Savant Power Storage 20 Commissioning Resources Download the Savant Power Storage app. Search “Savant Power Storage” in Apple App Store or Google Play, or scan the QR code below or on the packing box to download the app from Apple App Store or Google Play.
  • Page 39: Troubleshooting

    7. Troubleshooting In any cases of device failure, please check alarms on the Savant Power Storage app and proceed as instructed. If the Savant Power Storage app fails to connect to the device, check the status of each indicator and possible reasons and solutions as follows.
  • Page 40 Resolution – Inverter unit fault, including overload, short circuit, grid over voltage, over frequency, etc. Check if the load is abnormal. Reboot Savant Power Inverter. If it does not recover, shut it down and contact Solid Red – Abnormal connection/voltage of batteries. Check battery connection and battery voltage. Reboot Savant Power Inverter.
  • Page 41: Bcms Module/Battery System And Battery Module Led

    The battery system is in high voltage protection mode. Check if the communication cable for BCMS and EMS is disconnected; Leave it switched ON for 30 minutes. If it does not recover, shut it down and contact Savant support. The Status Indicator on BCMS module/battery system keeps blinking Battery system failed in self-inspection.
  • Page 42: Warranty And Service

    POWER STORAGE - WARRANTY Savant Power Storage has a ten (10) year or 73 MWh of throughput (equivalent to 3,650 cycles), whichever is sooner, limited warranty period for products that do not substantially conform to the applicable specifications. Products with a valid warranty claim within the warranty period will, at Savant’s election, be repaired, replaced with an equivalent product, or returned for an account credit, equivalent to the initial cost of product minus depreciation based on the amount of the warranty period remaining (i.e., if a valid warranty claim occurs with one year remaining in the ten year warranty period,...
  • Page 43: Appendix A: Supported Configurations

    Offsets power consumption while providing backup power for the whole home during a utility disruption. Requires enough battery and inverter capacity to pow- er all backed up loads or be paired with a Savant Power Energy Management System. Can be installed with or without solar sell back (“Net-Metering”) enabled.
  • Page 44 Easily integrate existing grid tied solar installations with off-grid resiliency and time-of-use optimization. NOTE: AC Coupled solar may land in the load center as pictured in the diagram below, or directly into the GEN input of the Savant Power Inverter. Contact Sa- vant engineering for more information about how to integrate a generator with an AC Coupled system.
  • Page 45: Appendix B: Emergency Stop Switch (-Stop) Installation

    CCA =Cloud connect advanced transmitter additional support. RSD Notes: - Each Savant Inverter has an RSD jumper installed in the wire closet out of the box. Leader Inverter If RSD is required within the local AHJ, this jumper needs to be removed. The installer...
  • Page 46 IMPORTANT! If the E-Stop is enabled before the E-Stop wiring is connected to the PS20, the system will automatically enter E-Stop mode. To return the system to normal operation, install a jumper cable in the Inverter to act as an E-Stop then continue to disable the E-Stop in the Savant Power Storage (SPS) app.
  • Page 47: Appendix C: Optional Accessories

    Acrel Meter Switch Installation The Meter Zero mode in the Savant Power Storage 20 enables the offset of non-backed up load consumption while grid connected. This mode requires an external power meter, the Acrel AGF-AE-D/200, which must be purchased separately. When an Acrel Meter is installed and the PS20 is integrated with a host or Director, then the mode must be set to either Meter Zero or Excess Solar to Grid.
  • Page 48 NOTE: The phasing powering the meter should match the CT placements for each phase. Identify the adapter included with Acrel Meter, and install with the appropriate instructions. RS485-B- RS485-A+ RJ45 Adapter Pigtail Adapter Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 48 -...
  • Page 49 NOTE: The RJ45 Terminal Adapter is pre-wired to Pins 7 and 8. CAT5 CABLE BCMS RS232 RS485-4 UPCS RS485-1 DC 12V RJ45 ADAPTER INVERTER ACREL METER Figure 13a: RJ45 Adapter Connections Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 49 -...
  • Page 50 13b). RS-485 ACREL/RECT BCMS CAB-INV485-00 RS232 CAB-INVBATT-02 RS485-B- RS485-A+ INVERTER RS485-4 UPCS RS485-1 DC 12V INVERTER ACREL METER Figure 13b: Pigtail Adapter Connections Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 50 -...
  • Page 51: Indicator Description

    Appendix C: Optional Accessories Ensure the Power Storage 20 is correctly commissioned and in standby mode (not charging, discharging, or producing solar power) before activating the breaker for the meter. 10. After turning on the breaker for the Acrel meter, wait up to 2 minutes for the meter to establish communication with the PS20. Verify there are no issues with the Acrel meter using the three LED indicators on the meter front.
  • Page 52 NOTE: While 4G and GPS antenna ports are available and may function, they are not supported in a PS20 system. 4G MAIN WIFI PARALLEL 4G DIV RESET Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 52 -...
  • Page 53: Appendix D: Single Line Diagrams

    NOTE for Parallel Installs: When installing AC wire between the upstream breakers in the Grid Combiner Panel to its respective Savant Power Storage 20 Grid input; the combined wire length from the Grid Distribution Panel to the Load Combiner Panel needs to be approximately equal across the PS20 units.
  • Page 54 Appendix D: Single Line Diagrams Home Back-Up using Single PS20 (12.5 kVA | 20 kWh) 100A POWER STORAGE 20 SYSTEM NOTES 20KWH RATED ENERGY STORAGE UTILITY CT METER 12.5KW / 52A OFFGRID CONTINUOUS EXISTING QTY (2) 8.5KW / 26A DC PV...
  • Page 55 Appendix D: Single Line Diagrams Home Back-Up Using Parallel Systems (25 kVA | 40 kWh) 200A POWER STORAGE 20 SYSTEM NOTES 40KWH RATED ENERGY STORAGE UTILITY CT METER 25KW / 104A OFFGRID CONTINUOUS QTY (4) 8.5KW / 26A DC PV...
  • Page 56 Appendix D: Single Line Diagrams Home Back-Up Using Parallel Systems (25 kVA | 20 kWh) 200A POWER STORAGE 20 SYSTEM NOTES 20KWH RATED ENERGY STORAGE UTILITY CT METER 25KW / 104A OFFGRID CONTINUOUS QTY (4) 8.5KW / 26A DC PV...
  • Page 57 Appendix D: Single Line Diagrams Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 57 -...
  • Page 58: Appendix E: Inverter Mounting Bracket

    Appendix E: Inverter Mounting Bracket Savant Power Storage 20 Installation Guide Copyright 2025 Savant Systems, Inc 009-2401-02 | 250401 - 58 -...
  • Page 59: Appendix F: Commissioning Checklist

    Appendix F: Commissioning Checklist Upon first boot up and commissioning of the Power Storage 20 System, the checklist below can be used as guidance to ensure a successful installation. Physical Wiring Checklist Physical Wiring Checklist (Parallel Systems Only) All wiring connections torqued to required values per installation guide..
  • Page 60 (Parallel Systems Only) Repeat start up process for all batteries and Inverter in system....................All batteries and inverters in system successfully turned on............................. Configure Power Storage 20 using Savant Power Storage App ..............................Inverter(s) added to device by scanning QR Code or inputting S/N..........................
  • Page 61 Add Inverter to Savant Power & Light (SP&L) App................................... Connect Load Output OCPD............................................Savant Power Storage app shows value for on-site load..............................Connect grid side OCPD and turn inverter Grid Switch to ON position and wait two to five minutes for inverter to connect to grid, depending on interconnection settings used ......................................