Instruction Manual (Before Use)
COMPACT pH METER
pH11,22,33
Preface
This manual describes the operation of the COM-
PACT pH METER, pH11,22,33.
Be sure to read this manual before using the
product to ensure proper and safe operation of the
instrument. Also safely store the manual so it is
readily available for reference whenever necessary.
Product specifications and appearance, as well as the
contents of this manual are subject to change without notice.
Warranty and responsibility
HORIBA Advanced Techno Co., Ltd. warrants that the
Product shall be free from defects in material and
workmanship and agrees to repair or replace free of
charge, at option of HORIBA Advanced Techno Co.,
Ltd., any malfunctioning or damaged Product attributable
to responsibility of HORIBA Advanced Techno Co., Ltd.
for a period of two (2) years from the delivery. However,
the warranty period of sensor is 6 months.
In addition, the warranty applies only when the sen-
sor repeatedly fails even after cleaning and
conditioning. In the following cases, none of the
warranties is valid;
Any malfunction or damage attributable to
improper operation
Any malfunction attributable to attempted repair
or modification by any person not authorized by
HORIBA Advanced Techno Co., Ltd.
Any malfunction or damage attributable to
violation of the instructions in this manual or
operations in an environment and the manner not
specified in this manual
Any malfunction or damage attributable to any
cause or causes beyond the reasonable control
of HORIBA Advanced Techno Co., Ltd. such as
natural disasters
Any deterioration in appearance attributable to
corrosion, rust, and so on
Replacement of consumables such as the stan-
dard solutions

Advertisement

loading
Need help?

Need help?

Do you have a question about the LAQUAtwin and is the answer not in the manual?

Questions and answers

Summary of Contents for horiba LAQUAtwin

  • Page 1 Warranty and responsibility  HORIBA Advanced Techno Co., Ltd. warrants that the Product shall be free from defects in material and workmanship and agrees to repair or replace free of charge, at option of HORIBA Advanced Techno Co.,...
  • Page 2 HORIBA Advanced Techno Co., Ltd. SHALL NOT BE LIABLE FOR ANY DAMAGES RESULTING FROM ANY MALFUNCTIONS OF THE PRODUCT, ANY ERASURE OF DATA, OR ANY OTHER USES OF THE PRODUCT. Trademarks  Company names and brand names are either registered...
  • Page 3 Contact your supplier for information on applicable disposal methods.  Authorised Representative in EU HORIBA Europe GmbH Hans-Mess-Str.6, D-61440 Oberursel, Germany FCC rules  Any changes or modifications not expressly approved by the party responsible for compliance shall void the user's authority to operate the equipment.
  • Page 4 Consumable parts sold separately  Name Type Part No. 3200459834 Sensor S010, pH 3999960108 514-4, pH 4.01 Standard solutions 3999960109 514-7, pH 7.00 3200053858 Sampling sheet B Y046, 100 sheet-pack CODE:GZ0000395601C mber,2019  2017 −2019 HORIBA Advanced Techno, Co., Ltd.
  • Page 5 Handling Precautions Meter and sensor  The sensor is a consumable part. If it becomes  damaged performance deteriorates, replace it with a new one (the sensor can not be repaired). Do not swing the meter and sensor using a strap. ...
  • Page 6 For some samples (such as pure water), the  measured value may be unstable. This is natural. A small amount of liquid or white powder may  appear on the liquid junction of the flat sensor. The appearance of this powder or solution is normal.
  • Page 7 Part Names Name Flat sensor Light shield cover 7 10 Liquid junction Glass membrane Lithium batteries MEAS switch ON/OFF switch CAL switch Waterproof gasket 10 Strap eyelet Initial Setup Detaching the sensor  Lift the sensor tongue slide sensor a little away from the meter.
  • Page 8 There is no need to switch the meter ON. Clean the flat sensor with running water. 31, Miyanonishi-cho, Kisshoin Minami-ku, Kyoto, 601-8306, Japan http://www.horiba-adt.jp For any questions regarding this product, please contact your local agency, or inquire from the following website.
  • Page 9 Instruction Manual (Operations) COMPACT pH METER pH11,22,33 Power ON/OFF Power ON  Press and hold the ON/OFF switch. The power is switched ON, and the meter model number is displayed on the LCD. Power OFF  Press and hold the ON/OFF switch. The power is switched OFF.
  • Page 10 Multi-point calibration  Select USA or NIST standard solutions for the calibration. Refer to "pH buffer set up mode" on the reverse side of this paper. Default is USA standard. Open the light shield cover and place some drops of the standard solution on the flat sen- sor taking care to cover the entire flat sensor.
  • Page 11 In the case of carrying out more than two- point calibration, repeat the steps 5. to 7. above.  Calibration error blinks and Er4 (error  display) appears, the calibra- tion has failed. Perform electrode conditioning. Check that the correct standard solution is used, and repeat cal- ibration after cleaning the sensor.
  • Page 12 Do not wipe or push the flat sensor strongly. It may damage the sensor. Please dab softly with a tissue or cloth to remove excess liquid. Close the light shield cover and the slide cap before storing the meter. CODE: GZ0000395601C mber,2019  2017 −2019 HORIBA Advanced Techno, Co., Ltd.
  • Page 13 Setup Mode The setup mode allows the user to customize the meter to his specific needs. To enter the setup mode, press and hold the MEAS and ON/OFF switches for over 3 seconds when the meter is switched OFF. All the LCD segments appear and then the meter enters the setup mode. To save the setting changes, press the CAL switch.
  • Page 14 Initialization mode  All setup choices are erased. Meter is reset to the factory default values. Press and hold the MEAS, CAL and ON/OFF switches for over 3 seconds when the meter is switched OFF to enter the initialization. All the LCD segments are displayed then software...
  • Page 15 Frequently asked questions Question Answer How can I check Perform a two-point calibration. If calibration the sensor's error occurs, the sensor has deteriorated. condition? Replace the sensor. This meter can not measure a sample with temperatures outside the meter's operating Can I measure temperature range (5 to 40C).