Chapter 6. Red Hat Network Website
and running. Refer to the RHN Satellite Server 4.0.5 Installation Guide for additional
information.
4. Add the systems to which the Probe Suite applies. Click the add systems to probe
suite link in the upper right of the screen to continue.
5. The next page displays a list of all systems with Monitoring entitlements. Check the
box to the left of the system(s) to which you wish to apply the Probe Suite, select the
monitoring scout you wish to use, and click the Add systems to probe suite button
to complete the creation of the Probe Suite.
You can either delete or detach probes from the suite. Detaching a probe disassociates the
probes from the suite and converts them to system-specific probes for the specified system.
This means that changes to the detached probes only effect that system. Deleting a probe
removes it from the Suite for all systems.
To remove probes from the Probe Suite:
1. From the Monitoring ⇒ Probe Suites page, click on the title of the Probe Suite you
wish to alter.
2. Select the Probes sub-tab.
3. Check the box next to the probe you wish to remove.
4. Click the Delete probes from Probe Suites button.
You may also remove a system from the Probe Suite. There are two ways to accomplish
this. The first method is to detach the system from the Probe Suite. When you
do so, the system still has the same probes assigned to it. However, you now have
the ability to configure these probes individually without affecting any other systems.
For more information about removing probes from an individual system, refer to
Section 6.4.2.8.9 System Details ⇒ Probes —
To detach a system from the suite:
1. From the Monitoring ⇒ Probe Suites page, click on the title of the Probe Suite you
wish to alter.
2. Select the Systems sub-tab.
3. Check the box next to the system(s) you wish to remove from the Probe Suite.
4. Click the Detach System(s) from Probe Suite button
The second method is to remove the system from the suite. This removes the system from
the suite and deletes all running probes from the system.
.