Download Print this page

Advertisement

Quick Links

4S15
4S15 ダイバー 
■ CAUTION (Be sure to observe the following.)
このたびはセイコーメカニカルウオッチ
・This watch is intended for use in sports diving (no-decompression diving). Never use the watch in
decompression diving, saturation diving using helium gas and diving at altitudes.
4S15をお買い上げいただきありがとうご
・Abide by the rules of sports diving for safety's sake.
ざいました。 
ご使用の前にこの取扱説明書をよくお読み
■ METHOD OF OPERATION
のうえ正しくご愛用くださいますようお願
い申し上げます。 
なお、この取扱説明書をお手もとに保存し、
Display and crown operation
必要に応じてご覧ください。 
Hour hand
目次
Second hand
1.
2.製品の説明
■ How to use the automatic mechanical watch
2−1−各部の名称とはたらき
(1) This is an automatic mechanical watch with manual winding mechanism.
2−2−自動巻き式機械時計の取扱いかた
(2) If the watch is worn on the wrist, the mainspring will be wound automatically through normal wrist
movement. It can also be wound up by turning the crown. To do so, unscrew the crown by turning it
2−3−時刻・日付表示の合わせかた
counterclockwise.
2−4−回転ベゼルの使いかた
2−5−夜光(ルミブライト)について
(3) To start the watch after it stops completely, wind it up either by turning the crown or swing it from
side to side until the second hand starts moving. Then, set the time and date before wearing the
watch on the wrist.
1. 使用禁止事項(ご使用の前に
・ヘリウムガスを使用する「飽和潜水」には絶
(一般スポーツダイバー用です)
(4) To wind up the watch, unscrew the crown by turning it counterclockwise, and then turn the crown
clockwise slowly. The watch cannot be wound by turning the crown counterclockwise. About 35
・スポーツダイビングのルールを守り、安全な
turns of the crown winds up the watch fully. Please note that the crown can be turned even after the
watch is wound up fully. While turning the crown, therefore, count the number of turns given to the
crown.
2.製品の説明
(5) Once the watch is wound up fully, it operates for about 40 hours. (If the watch is used without being
wound up fully, gain or loss of the watch may result. To avoid this, wear the watch for more than 8
hours a day.) If the watch is used without wearing on the wrist; if it is used on the desk, for
example; be sure to wind it up fully every day at a fixed time.
ダイバー 
取扱説明書 
INSTRUCTIN
使用禁止事項(ご使用の前に必ず
(自動巻) 
Rotating bezel
Minute hand
Date
Crown(the screw lock type)
Second click position (Time setting)
First click position (Date setting)
Unscrewed position
Screwed-in position (Locking the crown)
お読みいただきたいこと)
Turn the crown counterclockwise.
Turn the crown clockwise.
2−1 各部の名称とは
GL151-77
時針 

Advertisement

loading
Need help?

Need help?

Do you have a question about the 4S15 and is the answer not in the manual?

Questions and answers

Summary of Contents for Seiko 4S15

  • Page 1 4S15 GL151-77 ダイバー  (自動巻)  取扱説明書  INSTRUCTIN 4S15 ダイバー  ■ CAUTION (Be sure to observe the following.) このたびはセイコーメカニカルウオッチ ・This watch is intended for use in sports diving (no-decompression diving). Never use the watch in decompression diving, saturation diving using helium gas and diving at altitudes. 4S15をお買い上げいただきありがとうご ・Abide by the rules of sports diving for safety's sake. ざいました。  ご使用の前にこの取扱説明書をよくお読み ■ METHOD OF OPERATION のうえ正しくご愛用くださいますようお願 い申し上げます。  なお、この取扱説明書をお手もとに保存し、 Display and crown operation 必要に応じてご覧ください。  Rotating bezel Minute hand Date Hour hand 目次 Crown(the screw lock type) Second click position (Time setting) First click position (Date setting) Second hand Unscrewed position Screwed-in position (Locking the crown) 使用禁止事項(ご使用の前に必ず お読みいただきたいこと) 2.製品の説明 ■ How to use the automatic mechanical watch 2−1−各部の名称とはたらき...
  • Page 2 ■ Time/date setting The watch is provided with a date function and is so designed that the date changes once every 24 hours. The date changes around 12 o'clock midnight. If AM/PM is not properly set, the date will change at 12 o'clock noon. (1) Unscrew the (2) Pull out the crown crown by turning it to the first click. counterclockwise. Turn the crown   counterclockwise. (3) The date can be set by turning the crown clockwise. Turn it clockwise until the previous day's date appears. Clockwise: Date setting For example, if today is the 6th of the month, first set the date to  5" . Counterclockwise: Free Notes Do not set the date between 9:00 p.m. and 3:00 a.m. Otherwise, the date may not change properly. (4) Pull out the crown to the second click when the second hand is at the 12 o'clock position. Turn the crown to advance the hands until the date changes to the next. The time is now set for the A.M. period. Keep advancing the hands until the correct time. Notes ・To set the time, first set the hands to the time a few minutes behind the correct time, and then, advance the hands to the exact time. (5) Push the crown back in to the normal position in accordance with a time signal. (6) While pressing the crown, turn it clockwise until it locks in place. ●Date adjustment at the end of the month It is necessary to adjust the date at the end of February and 30-day months. <To adjust the date in the A.M. period on the first day of a month following a 30-day month> (1) The watch displays  31" instead of  1" . Unscrew the crown by turning it counterclockwise, and then, pull it out to the first click. (2) Turn the crown to set the date to  1" and then push the crown back in to the normal position. While pressing the crown, turn it clockwise until it locks in place.
  • Page 3 ■ PRECAUTIONS ON USING THE WATCH IN DIVING AND CARE OF THE WATCH AFTER DIVING Precautions before diving Check the following: (1) The crown is screwed in completely. (2) There are no visible cracks in the glass. ②  (3) The band is securely fastened to the watch case. ⑤  ④  (4) The rotating bezel is smoothly turning counterclockwise. ①  (5) The time and calendar are appropriately set. ③  Notes 1. Do not use the watch in saturation diving using helium gas. 2. If there are any malfunctions, contact the retailer from whom the watch was purchased or a SEIKO dealer. Precautions while diving (1) Do not operate the (2) Take care not hit the (3) Bezel rotation may become slightly crown when the watch against hard harder in the water but this is not a watch is in water. objects such as rocks. malfunction. Care of the watch after diving (1) After checking that the crown is screwed in completely, wrinse the watch in fresh water, and wash out all seawater, soil, sand, etc. (2) Wipe the watch thoroughly dry with a dry cloth, etc. (3) Do not expose the watch to chemicals. (4) For the care of the watch in general, refer to  5. PRECAUTIONS ON USING THE WATCH AND CARE OF THE WATCH" . ■ TROUBLESHOOTING TIPS Trouble...
  • Page 4 ×  (3) If the watch has a metal bracelet, periodically clean the bracelet with a soft toothbrush or the like soaked in soapy water. PERIODIC CHECK Do not leave the Do not expose the It is recommended that the watch be checked once every 2 years. A periodic check will prevent watch in a cold place watch to direct sunlight any damage from insufficient lubrication, battery or extreme heat. for a long time. electrolyte leakage, entrance of moisture or of between 5℃ and 35℃ perspiration, etc. and ensure longer use. To have it check, take your watch to the retailer from *If the watch is left in extremely high or low whom the watch was purchased or a SEIKO temperatures, a malfunction or a time loss/gain may DEALER. Your watch will be sent to a SEIKO result, or the watch may not operate properly. SERVICE CENTER to undergo a thorough MAGNETISM checking work is done. Depending on the result of checking, adjustment or repair may be ×  ×  required. If the watch has a urethane band, it will lose its elasticity and become hardened gradually over time. In that case, have it replaced with a new one by the retailer from whom the watch was purchased or a SEIKO dealer. The watch will be adversely affected by strong magnetism. Keep it away from close contact with STORAGE OF YOUR WATCH magnetic objects.