Dialogic DSI SS7MD Programmer's Manual page 64

Network interface boards
Table of Contents

Advertisement

6.3.4
LIU_MSG_R_CONTROL – LIU Read Control Request
Synopsis
Message sent by the application to read back the current Line Interface Unit (LIU) control options from the
board.
Format
type
id
src
dst
rsp_req
hclass
status
err_info
len
Offset
0
Description
This message is sent to the board to read back the current control parameters selected for a Line Interface
Unit (LIU). The user should always request a confirmation message. The confirmation message indicates
success when the status value of 0 and contains the current control parameters in the parameter area of the
message.
6.3.5
MVD_MSG_RESETSWX – Reset Switch Request
Synopsis
Resets the digital switch to its default state in accordance with the current board configuration.
Format
type
id
src
dst
rsp_req
hclass
status
err_info
len
Description
This message is sent to the board to reset the state of the digital cross connect switch.
64
6 Message Reference
Field Name
LIU_MSG_R_CONTROL (0x5e38)
liu_id (in the range 0 to one less than the number of LIUs)
Sending module ID
MVD_module_ID
Used to request a confirmation.
0
0
0
16
Size
Parameter area formatted in the same manner as the
LIU_MSG_CONTROL
All fields should be set to 0. The confirmation message contains LIU
16
control options.
The user should set the fields to 0 and the module writes the current
control parameters in the confirmation message.
Field Name
MVD_MSG_RESETSWX (0x7e00)
0
Sending module ID
MVD_module_ID
Used to request a confirmation.
0
0
0
0
MESSAGE HEADER
Meaning
PARAMETER AREA
Name
message.
MESSAGE HEADER
Meaning

Advertisement

Table of Contents
loading

Table of Contents