Download Print this page

KEPCO RAX 300W Series Instruction Manual

300 watt single output switching power supplies

Advertisement

Quick Links

I N S T R U C T I O N M A N U A L
KEPCO
I — INTRODUCTION
SCOPE OF MANUAL. This instruction manual covers the installation and operation of the Kepco RAX 300W Series of Switch-
ing Power Supplies. For service information, please refer to the Service Manual for the RAX 300W Series, which can be pur-
chased either from your Kepco Representative, or by writing directly to: Kepco Inc. 131-38 Sanford Avenue, Flushing, New York
11352, U.S.A. When ordering a Service Manual, please state Model Designation and Serial Number of your RAX power
supply. This information can be found on the nameplate of the unit.
DESCRIPTION. The Kepco RAX 300W Series consists of six models of switching power supplies, with a single output as shown
in Table 1. Units may be operated with either 115V a-c or 230V a-c 47-440Hz input. They will also operate on 240V to 370V d-c
input. The RAX 300W Series employs a light weight ferrite core with 145 KHz switching frequency. Regulation if provided by
pulse width modulation. A FET power stage, operating in the forward conversion mode provides a smooth isolated d-c output. A
triac "soft-start" circuit prevents excessive turn-on current surge. Overvoltage protection and optically isolated remote TTL on-off
control is provided. Current limiting with automatic recovery from short circuit is featured. Units are enclosed in a wrap-around
aluminum case with an LED "output present" light visible on the terminal side of the case.
Table 1 contains specifications and operating limits of individual RAX 300W Series models. Section II (following) contains spec-
ifications and operating limits common to all RAX 300W Series Models.
II — SPECIFICATIONS
The following specifications are at nominal input voltages at 25°C unless otherwise specified.
MODEL
OUTPUT VOLTS, d-c
ADJUSTMENT RANGE
MAXIMUM
50° C amb.
OUTPUT
60° C amb.
RATINGS
(AMPS,
71° C amb.
WATTS)
(1)
CURRENT LIMIT (AMPS)
OVP RANGE (VOLTS)
source (typ)
source (max)
RIPPLE
AND
switching (typ)
(2)
NOISE
(mV p-p)
switching (max)
spike noise
(3)
(max)
(1)
Change of current setting with the specified variations for operating temperatures and source input voltage is within ±10% of the rated values.
(2)
Source component 2x source frequency, and switching component approximately 145KHz.
(3)
Measured with a 50 MHz bandwidth.
INPUT VOLTAGE: (Jumper selectable, see Section III, FIG. 3):
120V a-c nominal, range: 85 -132V a-c, (90-132V a-c for model RAX 28-10K)
220-240V a-c nominal, range: 170 -264V a-c , (180-264V a-c for model RAX 28-10K)
320V d-c nominal, range: 240 -370V d-c
For d-c input the jumper is placed in the 230V position.
INPUT SOURCE FREQUENCY:
Nominal 50/60 Hz; Range 47-440 Hz. (At 440 Hz the leakage current exceeds the VDE safety specification limit.)
KEPCO, INC. !"! 131-38 SANFORD AVENUE !" FLUSHING, NY. 11352 U.S.A.!" TEL (718) 461-7000!" ! FAX (718) 767-1102!!
©2000 KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
300 WATT SINGLE OUTPUT
SWITCHING POWER SUPPLIES
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RAX 300W SERIES
RAX 5-60K
RAX 12-25K
5V
12V
4.0 - 5.5V
8.4 - 13.2V
60.0A/300W
25.0A/300W
42.0A/210W
17.5A/210W
24.0A/120W
10.0A/120W
65.0 - 70.0
28.0 - 30.0
6.0 - 6.9
13.7 - 15.7
5
15
10
30
25
25
40
50
100
170
http://www.kepcopower.com " ! email: hq@kepcopower.com
RAX 15-20K
RAX 24-12K
15V
12.0 - 16.5V
16.8 - 26.4V
20.0A/300W
12.0A/288W
14.0A/210W
8.4A/201.6W
8.0A/120W
4.8A/115.2W
22.0 - 24.0
13.2 - 14.4
17.0 - 19.5
27.0 - 30.5
15
30
25
50
200
228-1228 REV 2
RAX
CAUTION: UNIT IS SET
TO 115V AC OPERATION
RAX28-10K
24V
28V
19.6 -30.8V
10.0A/280W
7.0A/196W
4.0A/112W
12.0 - 16.0
32.0 - 35.0
25
30
40
60
25
25
60
60
290
330
RAX 48-6K
48V
32.6 - 52.8V
6.0A/288W
4.2A/201.6W
2.4A/115.2W
6.8 - 7.4
55.0 - 63.0
35
90
25
60
530
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the RAX 300W Series and is the answer not in the manual?

Questions and answers

Summary of Contents for KEPCO RAX 300W Series

  • Page 1 SCOPE OF MANUAL. This instruction manual covers the installation and operation of the Kepco RAX 300W Series of Switch- ing Power Supplies. For service information, please refer to the Service Manual for the RAX 300W Series, which can be pur- chased either from your Kepco Representative, or by writing directly to: Kepco Inc.
  • Page 2 0.5mA max at 120V a-c (U.L. Method) 0.75mA max at 240V d-c (U.L./VDE Method) KEPCO, INC. !"! 131-38 SANFORD AVENUE !" FLUSHING, NY. 11352 U.S.A.!" TEL (718) 461-7000!" ! FAX (718) 767-1102!! http://www.kepcopower.com " ! email: hq@kepcopower.com 228-1228 REV 2...
  • Page 3 PLACE AND CONNECT THE LOAD DIRECTLY TO THE BUS BAR. FIGURE 2. CONNECTING THE LOAD WITH ERROR SENSING KEPCO, INC. !"! 131-38 SANFORD AVENUE !" FLUSHING, NY. 11352 U.S.A.!" TEL (718) 461-7000!" ! FAX (718) 767-1102!! http://www.kepcopower.com " ! email: hq@kepcopower.com 3041271(2)
  • Page 4 KEPCO, INC. !"! 131-38 SANFORD AVENUE !" FLUSHING, NY. 11352 U.S.A.!" TEL (718) 461-7000!" ! FAX (718) 767-1102!! http://www.kepcopower.com " ! email: hq@kepcopower.com 228-1228 REV 2 092200 3041172...

This manual is also suitable for:

Rax 5-60kRax 12-25kRax 15-20kRax 24-12kRax28-10kRax 48-6k