Line-in Connections:
Dual 20 A Inputs
Bridged 20 A Input
20 A
FIG. 5
Line-in Connections
Connecting Dry Closures:
Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel.
1
5
6
7
8 COM
2
3
4
FIG. 6
Dry closures connection
Each contact closure connection (1 - 8) is pre-programmed with a default
preset. The table below shows the default presets for each contact
closure.
FIG. 8
Method A
FIG. 9
Method B
AMX Corporation reserves the right to alter specifications without notice at any time.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
The AMX logo is a trademark of AMX Corporation. AMX reserves the right to alter specifications without notice at any time.
3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993
Using two feeds for line 1 and line 2 provides
two, 20 A inputs.
Bridging line 1 and line 2 provides a single
20 A input.
Each contact (1 - 8) is pre-
programmed with a default preset.
Refer to the AMX Lighting Control
System instruction manual for
details on dry closure default presets
and recording new presets.
Lighting Application Drawings
043-019-2194 8/02 ©2002 AMX Corporation. All rights reserved.
Dry Closure Default Presets
Contact Closure
Default Function
1
Channel 1 at 100% in 1 second
2
Channel 2 at 100% in 1 second
3
Channel 3 at 100% in 1 second
4
Channel 4 at 100% in 1 second
5
Channel 5 at 100% in 1 second
6
Channel 6 at 100% in 1 second
7
Pack on (channels 1-6)
8
Pack off (channels 1-6
All other channels are undefined.
Setting AXlink and PROlink Address Numbers:
AXlink Address
Set the AXlink address number
(1-255) for the RDD-DM4. This
number must match the device
number in your Axcess program.
FIG. 7
Setting AXlink and PROlink address numbers
PROlink Address
Test
Use the PROlink DIP switch to set
the PROlink address number for the
RDD-DM4 (1-10).
Pin 8 on the PROlink DIP switch is
a test switch that turns all circuits on
to full.
Method A
120 VAC 1Ø /
Single-phase, four load
Method B
Typical 120 VAC
Single-pahse, four-wire
dual-feed