Device and Channel Keywords (Cont.)
DO_RELEASE
GET_PULSE_TIME
MASTER_SLOT
SET_PULSE_TIME
Define_Combine
This definition section allows the combination of functionally identical devices, such as identically
programmed Touch Panels and Softwire Panels. When the program references one of these devices,
all other combined devices in the set are also referenced. The set of devices, called a combine list,
must be enclosed in parentheses. For example:
DEFINE_COMBINE (PANEL1,PANEL2,PANEL3)
This combines the three devices PANEL1, PANEL2, and PANEL3. If an input change occurs on
any of the three devices, Axcess sees the input as coming only from the first device in the list
(PANEL1). If button [PANEL2,12] is pressed, Axcess will see the input as coming from
[PANEL1,12] due to the combination. Likewise, any output change that is sent to any device in the
list will automatically be sent to all devices in the list. This includes level changes. For example, the
statement ON [PANEL3,5Ø] will turn on channel 50 for all three devices in the list.
DEFINE_COMBINE is typically located immediately after the DEFINE_DEVICE section of a
program.
Axcess Programming Language
This keyword causes an input change from on to off to occur on a specified
device-channel without the device-channel being deactivated by external
means.
Here is the format:
DO_RELEASE (device,channel)
If a RELEASE statement corresponding to the device-channel is present in the
program, it will be executed. The DO_RELEASE keyword also forces the
release of a device-channel turned on by DO_PUSH.
This system variable contains the current duration of PULSEs and MIN_TO, as
set by SET_PULSE_TIME.
Time is measured in tenths of seconds, and the default is one half-second.
For example:
SET_PULSE_TIME(12)
P_TIME = GET_PULSE_TIME
The variable P_TIME now contains 12, or 1.2 seconds.
This keyword is useful only in limited situations, and its use is strongly discour-
aged.
This system variable returns a number which represents the slot in which the
Central Controller is plugged.
Ø represents slot 1, and 1 represents slot 2.
If this keyword is used in any system other than an AXF-BP (large CardFrame),
MASTER_SLOT will always return to Ø.
To set the length of time for PULSE, use the keyword SET_PULSE_TIME.
Time is measured in tenths of seconds, and the default is one half-second. The
PULSE time remains the same value until it is changed in the program. Here is
an example of SET_PULSE_TIME:
SET_PULSE_TIME(12)
This sets the current duration of PULSEs to 1.2 seconds. It recommended that
you return pulse time to the default setting of .5 seconds, as in the following
example:
SET_PULSE_TIME(5)