Appendix
Standard:
DEFINE_DEVICE
(* devices here *)
DEFINE_COMBINE
(* makes things more obvious *)
DEFINE_CONSTANT
(* constants here *)
10. Include files should be listed after all DEFINE_CALLs and before DEFINE_START.
Standard:
DEFINE_CALL 'IMPORTANT STUFF'
(* IMPORTANT STUFF CODE *)
INCLUDE 'MORECODE.AXI'
DEFINE_START
11. Comments and code should be in upper case. Line comments (except for those in the
DEFINE_DEVICE section should start at column 36, and section comments should take an
entire line, padded with asterisks.
Not recommended:
(*********************)
(* POWER OFF DEVICES *)
(*********************)
OFF [RELAY,1]
Off [relay,2]
Standard:
(* POWER OFF DEVICES *************************************)
OFF [SYS_PWR,1]
OFF [PWR_AMP,2]
12. CALL names and WAIT names are case sensitive and can be in upper and lower case.
Example: (These two CALLs are different!)
DEFINE_CALL 'SYSTEM POWER'
{
OFF [AMP,AMP_PWR]
WAIT 20 'VCR Power'
OFF [VCR,VCR_PWR]
}
DEFINE_CALL 'System Power'
{
OFF [AMP,AMP_PWR]
WAIT 20 'VCR Power'
OFF [VCR,VCR_PWR]
}
120
(* system power off *)
(* Amp power off *)
(* SYSTEM POWER OFF
(* AMP POWER OFF
(* AMP POWER OFF *)
(* VCR POWER OFF *)
(* AMP POWER OFF *)
(* VCR POWER OFF *)
(* CONTAINS CODE THAT
(* DOES VARIOUS THINGS *)
*)
*)
Axcess Programming Language
*)