Siemens GEB161.1E/MO Manual
Siemens GEB161.1E/MO Manual

Siemens GEB161.1E/MO Manual

Openair air damper actuators modbus rtu, non-spring return types
Hide thumbs Also See for GEB161.1E/MO:

Advertisement

OpenAir™
Air damper actuators Modbus RTU
GEB161.1E/MO, GIB161.1E/MO non-spring return types
A6V101037253_en--_d
2024-06-27
Air damper actuators 20 Nm / 35 Nm (non-spring return) with Modbus
communication
Nominal torque:
– GEB..: 20 Nm
(Legacy type: 15 Nm)
– GIB..: 35 Nm
Modbus RTU communication
Operating voltage: AC/DC 24 V
– (Legacy types: AC 24 V)
For air-handling units (AHU) and other ventilation applications
Smart Infrastructure

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GEB161.1E/MO and is the answer not in the manual?

Questions and answers

Summary of Contents for Siemens GEB161.1E/MO

  • Page 1 OpenAir™ Air damper actuators Modbus RTU GEB161.1E/MO, GIB161.1E/MO non-spring return types Air damper actuators 20 Nm / 35 Nm (non-spring return) with Modbus communication ● Nominal torque: – GEB..: 20 Nm (Legacy type: 15 Nm) – GIB..: 35 Nm ●...
  • Page 2 Stock number Operating Positioning Power consumption Runtime Manual Positioning voltage signal adjuster feedback GEB161.1E/MO S55499-D663 AC/DC 24 V Modbus RTU 2.6 VA / 1.7 W max. 150 s GIB161.1E/MO S55499-D856 3.4 VA / 2.4 W max. Legacy types: GEB161.1E/MO S55499-D298...
  • Page 3: Device Combinations

    (POL9..) Climatix range Data sheet: Q3900 Basic information on the Climatix product range (POL..) Related documents such as the environmental declarations, declarations of conformity, etc., can be downloaded from the following Internet address: www.siemens.com/bt/download Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 4 Actuator parameters (Opening direction, position limits, position adaptation, etc.). The value can be read over the Modbus register. Do not write parameters in cycles. See "Product documentation [▶ 3]" Address 255 is "unassigned" and must be set before the adapter can be operated. Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 5 For additional details, refer to Siemens information on disposal. Warranty service The application-specific technical data is guaranteed only in combination with the Siemens products listed in the 'Device combinations' section. If third-party products are used, any guarantee provided by Siemens will be invalidated. Siemens...
  • Page 6: User Interface

    Press button 5...10 s LED is red and turns off after 5 s. mode Release button LED is orange. (For use with Climatix controllers) Reset to factory settings Press button >10 s LED flashes orange. Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 7 2. Release the button while LED is still flashing.  LED flashes another 3 s  Press the button for 3 s to cancel the reset. 3. Press after the 3 s.  LED is red (Reset) while the device restarts. Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 8 An address can be stored at any time, i.e. after setting the 1-digits, or after setting the 1 and the 10-digits. The address entry is canceled if the button is released at the end of the entry before the LED is red. Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 9  LED flashes 1x red for each press of the button. 3. Save address (skip 10-digit and 100-digit): Hold pushbutton.  LED is red. 4. Release button  The address is saved and is repeated 1x for confirmation. Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 10: Modbus Registers

    Do not write parameters in cycles! If address 248 or higher is written to the register, the value automatically sets to the initial address 255 as soon as Reg. 268 is set to 1 ("Load"). Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 11 ● Firmware version Two bytes, HByte corresponds to 1289 1289 = 03 01 (hex) (HWord) major version; LByte to minor ● 1290 = 03 07 (hex) → 775 (dec) version → Firmware version = "03.01.0775" Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 12: Supported Function Codes

    ● 1412 = 2E 31 (hex) → .1 ● 1413 = 45 2F (hex) → E/ ● 1414 = 4D 4F (hex) → MO ➔ ASN = "GEB161.1E/MO" Register 769 "State" Status Bit 00 1 = Reserved Bit 06 1 = Adaptation done...
  • Page 13: Technical Data

    150 s Sound power level GEB.. <35 dBa (At a positioning of 150 s) GIB.. <45 dBa GEB.. Mechanical life Full cycles 100'000 Partial cycles 5'000'000 GIB.. Mechanical life Full cycles 60'000 Partial cycles 5'000'000 Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 14 <95 % r. F. Transportation IEC 60721-3-2 Climatic conditions Class 2K2 Temperature -32...70 °C Humidity, non-condensing <95 % r. F. Storage IEC 60721-3-1 Climatic conditions Class 1K3 Temperature -5...45 °C Humidity, non-condensing <95 % r. F. Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 15 17]" Applicable damper Round / GEB.. 8...20.5 mm / 8...14.5 mm 6.4...20.5 mm / 6.4...13 mm shafts square GIB.. 8.0...25.6 mm / 6.0...18 mm Min. length 20 mm The documents can be downloaded at http://siemens.com/bt/download. Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 16 Operating voltage on terminals G and G0 must comply with the requirements for SELV or PELV. Safety transformers featuring twofold insulation must be used as per EN 61558; they must be designed for 100% duty. Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 17 Dimensions Actuators GEB161.1E/MO Dimensions in mm GIB161.1E/MO Dimensions in mm Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 18 External Modbus interface Dimensions in mm [kg] [mm] 0.15 Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 19: Revision Numbers

    Revision numbers Type Stock number Valid as of Rev.-NO. GEB161.1E/MO S55499-D663 GIB161.1E/MO S55499-D856 Legacy types GEB161.1E/MO S55499-D298 GIB161.1E/MO S55499-D299 Was available until Sep. 2021 As long as stocks last Siemens A6V101037253_en--_d Smart Infrastructure 2024-06-27...
  • Page 20 Issued by © Siemens 2016 - 2024 Siemens Switzerland Ltd Technical specifications and availability subject to change without notice. Smart Infrastructure Global Headquarters Theilerstrasse 1a CH-6300 Zug +41 58 724 2424 www.siemens.com/buildingtechnologies Document ID A6V101037253_en--_d Edition 2024-06-27...

This manual is also suitable for:

Gib161.1e/moPol424.50/stdPol424.70/stdPol635.00/stdPol638.00/stdPol638.70/std ... Show all

Table of Contents