Young 03101-75 Instructions Manual

Wind sentry anemometer

Advertisement

METEOROLOGICAL INSTRUMENTS
INSTRUCTIONS
WIND SENTRY ANEMOMETER
MODEL 03101-75
R.M. YOUNG COMPANY
2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA
TEL: (231) 946-3980
FAX: (231) 946-4772
WEB: www.youngusa.com
P/N: 03101-75-90
REV: A070115

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 03101-75 and is the answer not in the manual?

Questions and answers

Summary of Contents for Young 03101-75

  • Page 1 METEOROLOGICAL INSTRUMENTS INSTRUCTIONS WIND SENTRY ANEMOMETER MODEL 03101-75 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com P/N: 03101-75-90 REV: A070115...
  • Page 2 DWG: W03101-75-90(A) REV: A070115 WIND SENTRY ANEMOMETER (NOVALYNX) Model 03101-75 is a modified version of the standard 03101 Wind Sentry Anemometer. This unit is supplied with 4.9m of Phoenix Contact Cable #1406006 as shown. 2 POLE PERMANENT MAGNET MOUNTED ON...
  • Page 3 METEOROLOGICAL INSTRUMENTS INSTRUCTIONS WIND SENTRY ANEMOMETER MODEL 03101 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com P/N: 03101-90 REV: A070115...
  • Page 4: Installation

    INTRODUCTION MODEL 03101 The Wind Sentry Anemometer measures horizontal wind speed. The WIND SENTRY ANEMOMETER small size, simplicity, and corrosion resistant construction provide a professional quality instrument at a modest cost. The cup wheel uses stainless steel precision instrument grade ball bearings which are lubricated with a wide temperature range high quality instrument oil.
  • Page 5: Maintenance

    Liability is limited to repair or replacement of defective item. A copy adjust the indicator to display 22.7 meters per second. (0.01250 X of the warranty policy may be obtained from R. M. Young Company. 1800 + 0.2 = 22.7)
  • Page 6 03101-90(A) Page 3...
  • Page 7: Cable & Wiring Diagram

    CABLE & WIRING DIAGRAM MODEL 03101 WIND SENTRY ANEMOMETER NOTE: THE EARTH GROUND CONNECTIONS MUST BE CONNECTED TO EARTH GROUND TO PROVIDE A STATIC DISCHARGE PATH. CONNECT THESE WIRES TO AN EARTH GROUND IN THE PROXIMITY OF THE SENSOR. 03101-90(A) Page 4...
  • Page 8 03133 RING MAGNET ASSY #3-48 X 1/2" PAN HD SCR 03127 LOWER HOUSING 18443 3 COND CABLE 10 FT R. M. YOUNG COMPANY 2801 Aero Park Drive , Traverse City, Michigan 49686 U.S.A. TEL (231) 946-3980 FAX (231) 946-4772 03101-90(A) Page 5...