Installation and Control Installation Manual (original instructions) N421132A - Rev.02 - 12/2024 RAC Solo (R32) P-MOZ20* - P-MOZ25*...
Page 2
By following the suggestions contained in this manual, the product you have purchased will provide trouble free operation, giving you optimum room temperatures with minimum energy costs. Panasonic Corporation Conformity This unit complies with the European directives: • RoHS 2011/65/UE •...
1. CodinG 1. CODING 1.1 Product related coding This instruction manual refers to the following product Check the correspondence with the technical rat- codes. ing plate on the product. See chapter "identifica- tion" p. 9. Code Size Connection side Control Panel Valves P-MOZ20IC5-E P-MOZ25IC5-E...
2. GEnERal inFoRmation 2. GENERALINFORMATION 2.1 About the manual I nthefigures This manual was written to provide all the explanations for the correct management of the device. 1 The numbers indicate the individual components. This instruction manual forms an integral part of the A The capital letters indicate component assemblies.
2. GEnERal inFoRmation to the instructions provided in this manual and the national It contains the list of products and/or accessories referred standards currently in force. to in the manual. To work on the refrigeration circuit, the installer must com- Generalinformation ply with the provisions of Regulation 303/2008/EC which It addresses all recipients.
2. GEnERal inFoRmation 2.2.1 S pecificwarningsforR32 The unit uses environmentally friendly R32 refrigerant gas, with a Global Warming Potential (GWP) = 675. Do This document contains only some of the warn- not release R32 gas into the atmosphere. ingsrelatedtotherefrigerantR32.Formorecom- R32 refrigerant gas is mildly flammable and odourless.
Page 8
2. GEnERal inFoRmation This symbol might be used in combination with a chemical symbol. In this case, it complies with the requirement set by the Directive for the chemical involved.
3. PRodUCt PRESEntation 3. PRODUCTPRESENTATION 3.1 I dentification the appliance can be identified by the rating plate: Technicalratingplate According to EU Regulation No. 517/2014 concerning certain fluorinated greenhouse gases, it is mandatory to indicate the total amount of refrigerant present in the installed system.
3. PRodUCt PRESEntation 3.4 Components Control Panel External air expulsion air outlet deflector External air intake front panel External fan Intake grid Room air probe air filter Internal exchanger Terminal block maximum level float Remote control Condensation drain valve Anti-lifting bracket Compressor Condensate drain Aesthetic side panel...
3. PRodUCt PRESEntation 3.5 Compatible accessories The accessories table refers to all products in the RAC Solo range. Please check the column Combinable products for correspondence with the purchased size. Combinable prod- Accessory description Code ucts Wall-mounted control panels Control panels LED electronic control panel with touch interface, wall mounted complete with thermostat and room temperature and relative humidity probe.
4. inStallation 4. INSTALLATION 4.1 Preliminary warnings ThissectionisdedicatedtotheInstaller.Thefea- The Manufacturer accepts no liability for damage turesoftheinstalleraredescribedinthe"Recipi- caused to animals or property due to failure to apply ents"p. 5chapter. the indicated rules which may cause malfunction of ap- pliances. Fordetailedinformationontheproducts,referto chapter"Technicalinformation"p. 51 The air conditioners without an external unit are de- signed for indoor installation.
4. inStallation 4.3 Dimensions and weights with packaging P-MOZ** Models m.u. Dimensions and weight for shipping Width 1100 1100 Height Total depth Weight 45,0 45,0 4.4 Handling with packaging 4.4.1 Preliminary warnings Handles the appliance must be handled only by qualified per- sonnel, adequately equipped and with equipment suit- able for the weight and dimensions of the appliance.
4. inStallation 4.5 Storage 4.5.1 Preliminary warnings Store in a clean and dry place. Store in accordance with the applicable national regu- S pecificwarningsforR32 lations. Store the box in a closed environment protected from Store the unit in such a way as to avoid mechanical atmospheric agents and isolate it from the floor using damage.
4. inStallation External fixed grid for air inlet and outlet (2 pcs front view) CR2025 3V remote control battery Screws and dowels kit (6 pcs) Wall-mounted roll-up tubes (2 pcs) Wall mounting bracket Energy efficiency label Instruction sheet for manual download QR Code scan label Remote control internal flanges...
4. inStallation • there are no obstacles to the free circulation of air Provide the following: through the holes (plants, leaves...) • a nearby drain for the outflow of condensate • the appliance must be installed in a position where it •...
Page 17
4. inStallation Holes for M8 dowels Electrical connection area Ø162 mm holes for air channelling ø 18 mm condensate drain anti-lifting bracket holed ø 8 mm 4.11.1 Preliminary warnings The unit requires two or more people to position the unit. The wall mounting bracket supplied as an accessory is required to position the unit on the wall.
4. inStallation 4.11.2 Installation arrangement Wall drilling for ducts Positioning the ducts Side of the wall towards the interior Plastic sheet for ducts Side of the wall towards the exterior Perimeter wall Unit Return and expulsion grilles outside air ducts ►...
Page 19
4. inStallation Paper template Spirit level Air intake damper Metal support Air expulsion damper fixing screw Support wall Expansion plug Chain ► use the paper template Counterflange Spring ► mark the positions of the fixing holes External air damper ► use a drill ►...
4. inStallation 4.11.3 Positioning Interlocking points Metal support ► fasten the unit to the upper part of the metallic sup- To facilitate connections, a spacer can be used to keep port the bottom of the unit away from the wall. ►...
Page 21
4. inStallation 4.12.2 Positioning Ifusingajugforcollectingthecondensation: Condensation drain stub Safety drain The device is factory supplied with a stub pipe connected Avoid the hermetic closure of the container. to the condensation drain connection. If it is not enough: ► remove the nozzle from the discharge connection Prevent the end of the drainage tube from falling below ►...
4. inStallation 4.12.3 Condensate drain pipe insulation Ifusinganopendrain: In case of condensate drain pipe use, the pipe must be If the condensation is not collected, it will be deposited coated with anti-condensation insulation for the internal on the support surface. The water could freeze if the part of the building and the wall.
Page 23
4. inStallation 4.13.2 Access to the electrical panel Intake grid Connectors front panel Electrical panel covering Control Panel fixing screws Access to the electrical panel is only permitted to qual- Disconnect the connector when opening the front pan- ified personnel. Toaccess: before carrying out any works, please ensure the power ►...
4. inStallation 4.13.4 CP occupancy contact input PE-IN Earth connection ACL-IN Phase connection ACN-IN Neutral Serial connection When the CP contact opens (very low voltage, connected to Presence contact (normally jumpered) a volt-free contact) the appliance is put is stand-by and CP appears on the display.
4. inStallation overhead installation fixing screws (supplied with the optional kit PCZ-Gb0737) Low installation (factory settings) Right support bracket for the flap Aesthetic lower cover kit (Code PCZ-Gb0737) 180° 4.14.2 C onfiguration Toconfigure ► refer to chapter "Installation position" p. 30 After completing the mechanical operations of changing the position of the mobile air outlet deflector, it is neces- for the appliance to work properly, each time the con-...
Page 26
4. inStallation Intake grid Connectors filter front panel Control Panel Side panel...
4. inStallation 4.17 Assembly of aesthetic panels and grilles ► place the side panel ► screw in the fixing screws ► screw in the fixing screws ► place the filter ► positioning the aesthetic panel ► positioning the grill ► connect the connector of the on-board control Side panel Control Panel front panel...
5. toUChPad and REmotE ContRol 5. TOUCHPADANDREMOTECONTROL 5.1 Interface 5.1.1 Description • show the operating status • show any alarms The touchpad control is supplied as standard on board the • select the various functions unit, does not require any connections and enables: 5.1.2 Touchpad Keys and functions related.
5. toUChPad and REmotE ContRol 5.2.2 Scale The range for °f is smaller, equivalent to -5 °C/5 °C. Tochangethetemperatureunitofmeasure 5.2.6 Wi-Fi reset ► select ► select °C or °f ToresettheWi-Ficredentialsandreturnthedevice By default the temperature unit of measure is ° C. toitsoriginalconfiguration ►...
5. toUChPad and REmotE ContRol 5.3.5 Connectivity expansion module TosettheHeatingonlyorCoolingonlymode ► select To enable or disable the connectivity expansion ► select HC to set the Heating and Cooling mode module ► select Ho to set the Heating only mode ► select ►...
6. Wall-moUntEd ContRol PCZ-EEB749 6. WALL-MOUNTEDCONTROLPCZ-EEB749 6.1 Interface 6.1.1 Description After 20 seconds after the last action the panel bright- ness is reduced, only the room temperature is seen on LED electronic control panels with touch interface for wall the display.
6. Wall-moUntEd ContRol PCZ-EEB749 6.1.3 Keys functions Keys area Up key Down key this can be used to switch the unit on or off allows you to activate the moving deflector Control function Allows you to control ventilation speed This can be used to select the operating mode (Cooling or Heating) or Autochangeover Enables the Automatic function Enables the Night function...
Page 33
6. Wall-moUntEd ContRol PCZ-EEB749 fixing screws back plate holes for fixing to electrical box Electrical back box Forwallmountingofthecontrolpanel: ► fix the back plate to the electrical back box with screws ► connect the electrical wiring before making the connections, please verify that the control terminal block is on the right-hand side.
6. Wall-moUntEd ContRol PCZ-EEB749 6.3 Single connection diagram Wall-mounted control panel Serial connection for wall-mounted remote control Terminal block for device connection 12 V-DC 1A power supply Presence contact (normally open) Wall-mounted control 12 V 230V 50Hz BRIDGE 485-COMM FILTER PE-OUT Reverse A and B for connecting the wall control panelwiththeboard.
6. Wall-moUntEd ContRol PCZ-EEB749 6.4 Connections 6.4.1 Preliminary warnings Tomaketheconnections: ► connect the + - power supply wires to a 12 V-DC 1A Theterminalsaccept: power supply • rigid or flexible wires with a 0.2 to 1 mm² cross-sec- ► connect the Modbus serial connection cables to ter- tion minals A and b •...
6. Wall-moUntEd ContRol PCZ-EEB749 6.5.4 Set the humidity setpoint Tonavigateinthemenu ► use the icons Tosetthehumiditysetpoint Toselectamenuitemandtoconfirmthechanges ► select made ► press to change settings ► press the icon ► increase or decrease the value with the icons Confirming the change takes you to the next item. Toexitthemenu ►...
6. Wall-moUntEd ContRol PCZ-EEB749 6.6 Advanced Menu Through the control panel, it is possible to access the ad- rC: Not used vanced menu. UC: Not used To access the advanced menu, it is first neces- sarytoaccessthebasicmenu.Seesection"Basic Ac: Not used menu"p. 35. Ah: Not used Toaccesstheadvancedmenu Ed: Extended display...
7. Wall-moUntEd ContRol CPCZ-EFB749 7. WALL-MOUNTEDCONTROLCPCZ-EFB749 7.1 Interface 7.1.1 Description After 20 seconds after the last action the panel bright- ness is reduced, only the room temperature is seen on LED electronic control panels with touch interface for wall the display.
7. Wall-moUntEd ContRol CPCZ-EFB749 7.1.3 Keys functions Keys area Up key Down key this can be used to switch the unit on or off allows you to activate the moving deflector Control function Allows you to control ventilation speed This can be used to select the operating mode (Cooling or Heating) or Autochangeover Enables the Automatic function Enables the Night function...
Page 40
7. Wall-moUntEd ContRol CPCZ-EFB749 fixing screws back plate holes for fixing to electrical box Electrical back box Forwallmountingofthecontrolpanel: ► fix the back plate to the electrical back box with screws ► connect the electrical wiring before making the connections, please verify that the control terminal block is on the right-hand side.
7. Wall-moUntEd ContRol CPCZ-EFB749 7.3 Single connection diagram Wall-mounted control panel Serial connection for wall-mounted remote control Terminal block for device connection 12 V-DC 1A power supply Presence contact (normally open) Wall-mounted control 12 V-DC 1A 230V 50Hz BRIDGE 485-COMM FILTER PE-OUT Reverse A and B for connecting the wall control...
7. Wall-moUntEd ContRol CPCZ-EFB749 7.4 Multiple connection diagram Wall-mounted control panel Serial connection for wall-mounted remote control Terminal block for device connection 12 V-DC 1A power supply Presence contact (normally open) Wall-mounted control 12 V 230V 50Hz BRIDGE 485-COMM 485-COMM FILTER PE-OUT Reverse A and B for connecting the wall control...
7. Wall-moUntEd ContRol CPCZ-EFB749 7.5 Connections 7.5.1 Preliminary warnings Terminalblockposition: Terminal block ( back view panel) The terminals for connecting the control panel and the presence contact CP are inserted in a plastic bag and placed inside the electrical box. Terminal blocks Tomaketheconnections: ►...
7. Wall-moUntEd ContRol CPCZ-EFB749 7.5.5 Extended display Keep the bipolar cable separate from power supply ca- ble by a minimum of 50 mm. To enable device connectivity and enable selection of Chase out the wall in order to minimise the length of fan power level, the display must be extended.
Page 45
7. Wall-moUntEd ContRol CPCZ-EFB749 Factory reset The setting range is from 20.0% to 90.0%. Toresetthefactoryparameters Setting the humidity hysteresis ► select ► press to change settings Tosetthehumidityhysteresis ► select No to keep current parameters ► select ► select Yes to reset the factory parameters ►...
Page 46
7. Wall-moUntEd ContRol CPCZ-EFB749 Ed: Extended display Fr: Not used To select digital input Tochangethedigitalinput ► select ► press to change settings ► select CP for contact presence (default) ► select Co to cooling open ► select CC to cooling close ►...
8. maintEnanCE 8. MAINTENANCE Routine maintenance is essential to keep the device effi- cient, safe, and reliable over time. 8.1 Preliminary warnings ThissectionisdedicatedtotheAuthorisedService Handle refrigerant with care. Leaking refrigerant can Centre.ThefeaturesoftheAuthorisedServiceCen- cause freezing. trearedescribedinchapter"Recipients"p. 5. Beforeeachcleaningandmaintenanceintervention: 8.1.1 S pecificwarningsR32 ►...
9. tRoUBlEShootinG 9. TROUBLESHOOTING 9.1 Troubleshooting table In the even of a malfunction, please refer to the following lem is not solved, please contact the Authorised Technical table. If, after performing the suggested checks, the prob- Assistance. Anomalies Possible causes Remedies Check there is power supply (by turning a light on, for example).
Page 50
9. tRoUBlEShootinG The appliance must not be installed in rooms where explosive gases develop or where there are humidity and temperature conditions that exceed the maximum levels reported on the installation manual. Clean the air filter regularly as described in the specific paragraph.
10. tEChniCal inFoRmation 10. TECHNICALINFORMATION 10.1 Technical data P-MOZ** Models m.u. Cooling performance (AT 35°C; AT 27°C) Maximum cooling capacity Dual Power 2,64 3,10 Nominal cooling capacity 2,09 2,33 Minimum Cooling Capacity 0,83 0,92 Dehumidification capacity total input power 0,64 0,72 3,29...
Page 52
10. tEChniCal inFoRmation P-MOZ** Models m.u. Refrigerant gas data Type of refrigerant Quantity of refrigerant 0,50 0,50 Compressor Rotary DC Inverter 1. Outdoor air temperature 35 °, relative humidity 41%. Ambient temperature 27 ° C; relative humidity 47%. Performance according to EN 14511 2.
10. tEChniCal inFoRmation 10.2 Dimensions 1010 P-MOZ** Models m.u. Product dimensions and weight Width 1010 1010 Height Total depth Empty weight 41,0 41,0 Wall hole diameter Wall holes distance 10.3 RED Compliance Statement Compliancewith2014/53/EURadioEquipmentDirec- bands used and the maximum Rf transmit power of the tive(RED).
10. tEChniCal inFoRmation 10.4 Safety This equipment is designed with the utmost care for the All guidelines must therefore be allowed at all times to en- safety of those who install and use it. sure safe use of the equipment. However, special attention must be paid to the dangers of electric shock and static electricity when working with elec- trical equipment.