Safety Information
General information
Read this manual carefully before installation and store it safely for future reference.
Installing the unit
Guidance on installing the air conditioner unit safely and correctly as per manual instructions.
Preparation of fire extinguisher
Details on having appropriate fire extinguishing equipment available for hot work.
Ignition sources free
Instructions to keep potential ignition sources away from the work area.
Area ventilation
Ensuring the work area is well-ventilated before, during, and after hot work.
Leakage detection methods
Procedures for detecting refrigerant leaks using appropriate methods and equipment.
Labelling
Ensuring parts are labelled for decommissioning and to notify flammable refrigerant content.
Recovery
Procedures for safely removing and storing refrigerant during servicing or decommissioning.
Power supply line, fuse or circuit breaker
Guidelines for ensuring compliant and safe power supply connections.
Installation Procedure
Choosing the installation location
Guidance on selecting an appropriate location for the air conditioner unit, considering room area and height.
Installation location requirements
Specifies requirements for outdoor unit placement, clearances, and installation height.
Fixing the outdoor unit in place
Instructions on securely installing the outdoor unit on a rigid base using anchor bolts.
Outdoor unit dimensions
Provides dimensions for different outdoor unit models for installation planning.
Minimum clearances for the outdoor unit
Details the required clearance space around the outdoor unit for proper ventilation.
Installing multiple outdoor units
Specifies clearance requirements when installing more than one outdoor unit.
Moving the outdoor unit with wire rope
Instructions on safely moving the outdoor unit using wire ropes and protective cloth.
Fixing the outdoor unit to a wall with a rack
Optional method for securing the outdoor unit to a wall using a rack for vibration dampening.
Connecting power, communication, and controller cables
Step-by-step guide for connecting electrical cables to the outdoor unit.
Air conditioning system examples
Illustrates example wiring diagrams for single-phase systems with ELCB.
Connecting the main power cable
Detailed instructions for connecting the main power cable to the unit.
Main power cable specifications
Lists specifications for power cables, including model compatibility and current ratings.
DRED wiring diagram
Provides a wiring diagram for the DRED controller connection.
Outdoor-to-indoor power terminal specifications
Details specifications for connecting power and communication terminals between units.
Outdoor-to-indoor cable specifications
Specifies cable types, sizes, and tightening torques for connections.
Extending the power cable
Step-by-step guide for safely extending the unit's power cable.
Connecting the refrigerant pipe
Instructions for connecting the refrigerant pipes between indoor and outdoor units.
Cutting and flaring the pipes
Detailed steps and specifications for properly cutting and flaring refrigerant pipes.
Connecting and removing air from the circuit
Guide to connecting pipes and evacuating air from the refrigerant circuit.
Adding refrigerant (R-32)
Procedures and precautions for adding R-32 refrigerant to the system.
Calculating refrigerant quantity
Method for calculating the amount of refrigerant to add based on pipe length.
Performing the gas leak test
Steps for conducting gas leak tests using nitrogen and a leak detector.
Connecting the drain hose to the outdoor unit
Instructions for installing a drain hose on the outdoor unit for condensate removal.
Insulating the refrigerant pipes
Guidance on insulating refrigerant pipes to prevent condensation and ensure efficiency.
Checking the earthing
Procedures for ensuring proper earthing connection for electrical safety.
Final check and trial operation
Steps for performing final checks and conducting a trial operation of the unit.
Outdoor unit settings and modes
Details on using the K4 button to view system status and select modes.
Setting outdoor unit options manually
Guide to manually setting outdoor unit options and addresses via buttons.
Extra Procedures
Pumping down refrigerant
Procedure to collect all system refrigerant into the outdoor unit before disconnection.
Relocating indoor and outdoor units
Steps for safely moving and reinstalling the indoor and outdoor units.
Using the stop valve
Instructions on how to open and close the stop valve correctly.
Closing the stop valve
Detailed steps for securely closing the stop valve.
Maintenance Procedures
Performing gas leak tests for repair
Procedure for testing refrigerant circuits for leaks during repair.
Decommissioning
Requirements for safely decommissioning the air conditioner unit.
Appendix
Troubleshooting
Lists error codes and their meanings for diagnosing operational issues.