Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Samsung Manuals
Air Conditioner
AC052TNHDKG
Installation manual
Samsung AC052TNHDKG Installation Manual
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
page
of
32
Go
/
32
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
Safety Information
General Information
Installing the Unit
Preparation of Fire Extinguisher
Ignition Sources Free
Area Ventilation
Leakage Detection Methods
Labelling
Recovery
Power Supply Line, Fuse or Circuit Breaker
Installation Procedure
Step 1 Choosing the Installation Location
Step 2 Fixing the Outdoor Unit in Place
Step 3 Connecting the Power Cables, Communication Cable, and Controllers
Step 4 Optional: Extending the Power Cable
Step 5 Connecting the Refrigerant Pipe
Step 6 Optional: Cutting and Flaring the Pipes
Step 7 Connecting up and Removing Air in the Circuit
Step 8 Adding Refrigerant (R-32)
Step 9 Performing the Gas Leak Test
Step 10 Connecting the Drain Hose to the Outdoor Unit
Step 11 Insulating the Refrigerant Pipes
Step 12 Checking the Earthing
Step 13 Performing Final Check and Trial Operation
Extra Procedures
Pumping down Refrigerant
Relocating the Indoor and Outdoor Units
Using the Stop Valve
Maintenance Procedures
Performing the Gas Leak Tests for Repair
Decommissioning
Appendix
Troubleshooting
Advertisement
Quick Links
1
General Information
2
Step 3 Connecting the Power Cables, Communication Cable, and Controllers
3
Step 13 Performing Final Check and Trial Operation
4
Troubleshooting
Download this manual
Air conditioner
Installation manual
AC***TXAPKG
• Thank you for purchasing this Samsung air conditioner.
• Before operating this unit, please read this manual carefully and retain it for future
reference.
DB68-08482A-01
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the AC052TNHDKG and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Samsung AC052TNHDKG
Air Conditioner Samsung AC035FCADEH/EU Service Manual
System air conditioner (115 pages)
Air Conditioner Samsung AC024JXADCH Installation Manual
(40 pages)
Air Conditioner Samsung AC018KNZDCH/AA Service Manual
Ahu series (72 pages)
Air Conditioner Samsung AC036JB1DEC Service Manual
(92 pages)
Air Conditioner Samsung AC052MN4DKH Service Manual
System air conditioner 4 way cassette series (101 pages)
Air Conditioner Samsung AC052MNCDKH Service Manual
System air conditioner ceiling series (87 pages)
Air Conditioner Samsung AC MXADKH Series Installation Manual
(56 pages)
Air Conditioner Samsung AC052FBMDEH/EU Service Manual
System air conditioner (99 pages)
Air Conditioner Samsung AC052MNMSEH Service Manual
System air conditioner, indoor/outdoor unit (84 pages)
Air Conditioner Samsung AC RN DKG Series Installation Manual
(36 pages)
Air Conditioner Samsung AC026RN1DKG Service Manual
System air conditioner (257 pages)
Air Conditioner Samsung AC071RNNDKG/EU User Manual
(22 pages)
Air Conditioner Samsung AC NN1PKC Series Installation Manual
(32 pages)
Air Conditioner Samsung AC FB4DEH Series User Manual
(21 pages)
Air Conditioner Samsung AC052BN6PKG User Manual
(24 pages)
Air Conditioner Samsung AC052FBRDEH Service Manual
(72 pages)
Summarization of Contents
Safety Information
General information
Read this manual carefully before installation and store it safely for future reference.
Installing the unit
Guidance on installing the air conditioner unit safely and correctly as per manual instructions.
Preparation of fire extinguisher
Details on having appropriate fire extinguishing equipment available for hot work.
Ignition sources free
Instructions to keep potential ignition sources away from the work area.
Area ventilation
Ensuring the work area is well-ventilated before, during, and after hot work.
Leakage detection methods
Procedures for detecting refrigerant leaks using appropriate methods and equipment.
Labelling
Ensuring parts are labelled for decommissioning and to notify flammable refrigerant content.
Recovery
Procedures for safely removing and storing refrigerant during servicing or decommissioning.
Power supply line, fuse or circuit breaker
Guidelines for ensuring compliant and safe power supply connections.
Installation Procedure
Choosing the installation location
Guidance on selecting an appropriate location for the air conditioner unit, considering room area and height.
Installation location requirements
Specifies requirements for outdoor unit placement, clearances, and installation height.
Fixing the outdoor unit in place
Instructions on securely installing the outdoor unit on a rigid base using anchor bolts.
Outdoor unit dimensions
Provides dimensions for different outdoor unit models for installation planning.
Minimum clearances for the outdoor unit
Details the required clearance space around the outdoor unit for proper ventilation.
Installing multiple outdoor units
Specifies clearance requirements when installing more than one outdoor unit.
Moving the outdoor unit with wire rope
Instructions on safely moving the outdoor unit using wire ropes and protective cloth.
Fixing the outdoor unit to a wall with a rack
Optional method for securing the outdoor unit to a wall using a rack for vibration dampening.
Connecting power, communication, and controller cables
Step-by-step guide for connecting electrical cables to the outdoor unit.
Air conditioning system examples
Illustrates example wiring diagrams for single-phase systems with ELCB.
Connecting the main power cable
Detailed instructions for connecting the main power cable to the unit.
Main power cable specifications
Lists specifications for power cables, including model compatibility and current ratings.
DRED wiring diagram
Provides a wiring diagram for the DRED controller connection.
Outdoor-to-indoor power terminal specifications
Details specifications for connecting power and communication terminals between units.
Outdoor-to-indoor cable specifications
Specifies cable types, sizes, and tightening torques for connections.
Extending the power cable
Step-by-step guide for safely extending the unit's power cable.
Connecting the refrigerant pipe
Instructions for connecting the refrigerant pipes between indoor and outdoor units.
Cutting and flaring the pipes
Detailed steps and specifications for properly cutting and flaring refrigerant pipes.
Connecting and removing air from the circuit
Guide to connecting pipes and evacuating air from the refrigerant circuit.
Adding refrigerant (R-32)
Procedures and precautions for adding R-32 refrigerant to the system.
Calculating refrigerant quantity
Method for calculating the amount of refrigerant to add based on pipe length.
Performing the gas leak test
Steps for conducting gas leak tests using nitrogen and a leak detector.
Connecting the drain hose to the outdoor unit
Instructions for installing a drain hose on the outdoor unit for condensate removal.
Insulating the refrigerant pipes
Guidance on insulating refrigerant pipes to prevent condensation and ensure efficiency.
Checking the earthing
Procedures for ensuring proper earthing connection for electrical safety.
Final check and trial operation
Steps for performing final checks and conducting a trial operation of the unit.
Outdoor unit settings and modes
Details on using the K4 button to view system status and select modes.
Setting outdoor unit options manually
Guide to manually setting outdoor unit options and addresses via buttons.
Extra Procedures
Pumping down refrigerant
Procedure to collect all system refrigerant into the outdoor unit before disconnection.
Relocating indoor and outdoor units
Steps for safely moving and reinstalling the indoor and outdoor units.
Using the stop valve
Instructions on how to open and close the stop valve correctly.
Closing the stop valve
Detailed steps for securely closing the stop valve.
Maintenance Procedures
Performing gas leak tests for repair
Procedure for testing refrigerant circuits for leaks during repair.
Decommissioning
Requirements for safely decommissioning the air conditioner unit.
Appendix
Troubleshooting
Lists error codes and their meanings for diagnosing operational issues.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the AC052TNHDKG and is the answer not in the manual?
Questions and answers