Murdock A132-VR-BF4 Series Installation & Maintenance Instructions Manual

Barrier free, bi-level, wall mounted drinking fountain with semi-recessed sensor and pushbutton operated bottle filler and 32” trim panel

Advertisement

Barrier Free, Bi-Level, Wall Mounted Drinking Fountain with
Semi-Recessed Sensor and Pushbutton Operated Bottle Filler and 32" Trim Panel
A132400S-VR-BF3
A132400F-BF3 / A132400S-BF4 & A132400F-BF3-RBL / A132400S-BF4-RBL,
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
Technical Assistance E-Mail: fieldservice@acorneng.com
NOTES TO INSTALLER:
1. Please leave this documentation with the owner of the fixture when finished.
2. Please read this entire booklet before beginning the installation.
3. Check your installation for compliance with plumbing, electrical and other applicable codes.
®
Murdock assumes no responsibility for use of void
®
or suspended data. © Copyright Murdock , City of
Industry, CA Member of Morris Group International .
Please visit www.murdockmfg.com for most
current specifications.
7021-015-001
Date: 03/17/2023 A
CONTEMPORARY WATER COOLERS
DRINKING FOUNTAINS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
A132-VR-BF3 and A132-VR-BF4 Series
** U.S. DESIGN PATENT D545,607 (Bowl Design)
1.800.591.9360
®
NSF/ANSI/CAN 61
A132400S-VR-BF4
Federal
Public Law
111-380
(No Lead)
Member of
15125 Proctor Ave,
City of Industry, CA
91746 U.S.A.
Phone 800-453-7465
626-333-2543
www.murdockmfg.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A132-VR-BF4 Series and is the answer not in the manual?

Questions and answers

Summarization of Contents

Installation Overview and Preparation
Important Usage and Safety Information
Fixture is intended to dispense water; avoid electrical feedback causing electrolysis.
Dielectric Coupling Requirement
A dielectric coupling must be used to connect the drinking fountain to the water supply.
Roughing-In and Dimensional Drawing
Provides detailed dimensions and rough-in requirements for installation.
Installation Procedures
Wall Opening and Support Preparation
Prepare wall opening and provide structural support for frame anchoring.
Component Preparation and Handling
Carefully remove mounting frame, trim panel, and bottle filler assembly from packaging.
Frame Mounting and Securing
Center frame assembly in wall opening and secure to wall with hardware.
Pre-Installation Checks
Read instructions, check components, ensure adequate mounting surface and rough-ins.
Important Installation Requirements
Details water supply, waste, electrical, pressure, and code requirements for installation.
Drinking Fountain Installation Steps
Steps for installing the mounting frame, securing the fixture, and connecting waste and water supply.
Bottle Filler Installation
Connect water supply, orient P-trap, make power connections (BF4), and test for leaks.
Drinking Fountain Start Up
Procedure for turning on water supply, checking for leaks, and adjusting flow.
Bottle Filler Start Up
Procedure for starting up the bottle filler, including sensor and pushbutton operation.
Water Tubing Connections
Diagram and notes for connecting water tubing for the drinking fountain and bottle filler.
Optional Features Installation
Optional WF1 Water Filter Installation
Guide for installing the optional WF1 water filter and its components.
WF1 Filter Cartridge Replacement
Steps for closing the water inlet valve, removing and replacing the filter cartridge.
Electrical Installation
Instructions for connecting the plug-in transformer to GFCI protected service for the bottle filler.
Bottle Counter Adjusting and Resetting
Instructions for adjusting and resetting the bottle counter display functions.
Bottle Counter Filter Replacement Functions
Details on the 'REPLACE FILTER' alert and how to set filter status.
Clearing Replace Filter Alert
Procedure to clear the 'REPLACE FILTER' alert after replacing the filter.
Bottle Filler and Counter Connections
Diagram showing electrical connections for bottle filler and bottle counter components.
Fitting Installation and Troubleshooting
Push-In Fitting Installation
Instructions for cutting, inserting, and disconnecting push-in fittings.
Cutting the Tubing
Instructions on how to cut 1/4" PE tubing, ensuring clean and square edges.
Inserting Tubing into Fittings
Steps for firmly inserting tubing into push-in fittings and testing for security.
Disconnecting Tubing from Fittings
Procedure for safely disconnecting tubing from push-in fittings after depressurizing.
Troubleshooting Guide
Guidance for resolving common issues with adjustments, water flow, and drips.
Troubleshooting Adjustments
Adjusting water flow, cold water thermostat, and bubbler stream.
Troubleshooting Restricted or No Water Flow
Checks for water supply, kinks, strainer clogs, and power issues.
Troubleshooting Water Drips or Shut-Off Issues
Steps to resolve water drips or failure to shut off, including valve cartridge replacement.
Sensor Troubleshooting
Diagnosing issues with the sensor light not flashing or flashing once.
Maintenance and Parts Breakdown
Cleaning and Maintenance Guide
Instructions for cleaning the unit, compressor, condenser, and stainless steel surfaces.
Cartridge Replacement and Strainer Maintenance
Procedures for replacing the valve cartridge and maintaining the strainer.
Drinking Fountain Parts Breakdown
Diagram and list of parts for the drinking fountain unit.
A132-BF4 Series Breakdown Drawing
Exploded view diagram of the A132-BF4 series components.
A132-BF3 Series Breakdown Drawing
Exploded view diagram of the A132-BF3 series components.

Table of Contents