Service Hints; Technical Service - Desa CRL3124PA/NA Owner's Operation And Installation Manual

Unvented (vent-gree) gas log heater
Table of Contents

Advertisement

1. Shut off unit, including pilot. Allow unit to
cool for at least thirty minutes.
2. Inspect burner, pilot and primary air inlet
holes on injector holder for dust and dirt
(see Figure 35).
3. Blow air through the ports/slots and holes
in the burner.
4. Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint or pet
hair with a soft cloth or vacuum cleaner
nozzle.
5. Blow air into the primary air holes on the
injector holder.
6. In case any large clumps of dust have now
been pushed into the burner repeat steps
3 and 4.
Clean pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot
assembly. There is a small pilot air inlet hole
about 2" from where the pilot flame comes out
of the pilot assembly (see Figure 36). With the
unit off, lightly blow air through the air inlet
hole. You may blow through a drinking straw
if compressed air is not available.
Burner Tube
Primary Air
Inlet Holes
Figure 35 - Injector Holder On Outlet
Burner Tube

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• for propane/LP units, propane/LP gas sup-
ply may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
24
CLEANING AND MAINTENANCE
Injector Holder
www.desatech.com
Continued
Burner Tube
Pilot Assembly
Figure 36 - Pilot Inlet Air Hole
LOGS
• If you remove logs for cleaning, refer to
Installing Logs, page 16, to properly replace
logs.
• Replace log(s) if broken or chipped (dime-
sized or larger).
MAIN BURNER
Periodically inspect all burner flame holes with
the heater running. All slotted burner flame
holes should be open with yellow flame pres-
ent. All round burner flame holes should be
open with a small blue flame present. Some
burner flame holes may become blocked by
debris or rust, with no flame present. If so,
turn off heater and let cool. Remove blockage.
Blocked burner flame holes will create soot.

TECHNICAL SERVICE

You may have further questions about installa-
tion, operation, or troubleshooting. If so, con-
tact DESA Heating, LLC at 1-866-672-6040.
When calling please have your model and
serial numbers of your heater ready.
You can also visit DESA Heating, LLC's web
site at www.desatech.com.
Ports/Slots
Pilot Air
Inlet Hole
113097-01L