Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note: Where listed vented decorative logs are re-
quired, thermostat operation is not permitted.
CAUTION: Do not remove the
data plates from the grate as-
sembly. The data plates contain
important product information.
1. Remove logs and heater base assembly
from carton. Note: Do not pick up heater
base assembly by burners. This could
OPERATION
This heater is clean burning. It requires no outside
venting. There is no heat loss out a vent or up a
chimney. Heat is generated by realistic dancing,
yellow flames. This heater is designed for vent-
free operation with flue damper closed. It has been
tested and approved to ANSI Z21.11.2 standard
for unvented heaters. State and local codes in
some areas prohibit the use of vent-free heaters.
This heater may also be operated as a vented
decorative (ANSI Z21.60) product by opening the
flue damper (non-thermostat operation only).
113097-01L

PRODUCT IDENTIFICATION

Log Set
Piezo
Ignitor
Control Knob
Base Grate
Figure 1 - Vent-Free Gas Log Heater

LOCAL CODES

UNPACkING

PRODUCT FEATURES

www.desatech.com
Burner
State of Massachusetts: The installa-
tion must be made by a licensed plumber
or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
damage heater. Always handle base as-
sembly by grate.
2. Remove all protective packaging applied
to logs and heater for shipment.
3. Check heater for any shipping damage.
If heater is damaged call DESA Heating,
LLC at 1-866-672-6040 for replacement
parts before returning to dealer.
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free
room heaters. The ODS/pilot shuts off the
heater if there is not enough fresh air.
PIEzO IGNITION SYSTEM
This heater has a piezo ignitor. This system re-
quires no matches, batteries or other sources
to light heater.