T H E
R E S U L T
V I E W
your system, e.g. if you have not purchased PESQ, the PESQ result values
will not be available in the result view, as a consequence. Most measured
parameters correspond to values determined by OPERA™. Please refer to the
OPERA™ manual for a detailed description.
Column Title
Description
Comment
The comment which is related to the command.
CommentO
The comment which is related to the originating resource.
CommentT
The comment which is related to the terminating resource.
Origin
The resource name of the interface which originated the call.
Termination
The resource name of the interface which terminated the call.
Index
A sequential index of the test measurements
Time
Time in UTC at which the command was started.
RepCount
Counts the repetitions of the command
MaxRep
Corresponds to "Repetitions" in the command definition
CallingSys
Name of the system that originated the call.
Calling Line
Index of the line interface used to originate the call
CalledNumber
Telephone number dialed
CalledSys
Name of the system that terminated the call.
Called Line
Index of the line interface used to terminate the call
RefFile
The name of the file which was sent from the terminating side to the
originating side
FileCaller
The name of the file which was recorded at the originating side
(degraded signal)
FileCalled
The name of the file which was recorded at the terminating side
(echo signal)
Tpdd
Post dial delay in ms, including the time required to detect the ring-
back tone (app. 2..3s, country specific)
Tring
Currently not used, please ignore.
Duration
Total duration of the call (including dialing etc.)
TermCause
Termination cause. If it is "connect", the call was successful, all
other values (busy, disconnected...) identify missed call attempts.
PsqmOMOS_W2
The MOS according to PSQM / P.861 using a silence weight of 0.2.
PsqmPlusOMOS
The MOS according to PSQM+.
PsqmDelay
The delay in ms as determined by OPERA™ during calculation of
PSQM.
Attenuation
The attenuation of the line in dB.
EchoDelay
The delay of the severest echo component in ms.
ERL
The echo return loss of the severest echo component in dB,
measured with real speech.
PesqMOS
The MOS according to PESQ / P.862
PesqMOSsp
PESQ / P.862 MOS of the speech parts of the test signal
PesqMOSbg
PESQ / P.862 MOS of the background noise parts of the test signal
DelayMin
The minimum delay in ms during the call as determined by PESQ /
P.862
DelayAvg
The average delay in ms during the call as determined by PESQ /
P.862
DelayMax
The maximum delay in ms during the call as determined by PESQ /
P.862
LoudnessRefSone
Loudness of the reference signal measured in Sone
LoudnessDegSone
Loudness of the degraded signal measured in Sone
LoudnessBackSone Loudness of the background noise parts of the degraded signal
measured in Sone
LevRefTotdBov
Level in dBov averaged over the total of the reference signal
LevRefSpdBov
Level in dBov of the speech parts of the reference signal