Vibration testing

Advertisement

Opticom Technologies Inc.
SAE J1455 and MIL-STD-810F
Vibration Testing of
Model CC-02-4.3
CCTV Camera
Prepared by: Weir-Jones Engineering Consultants Ltd.
2040 West 10th Avenue
Vancouver, B.C.
V6J 2B3
Tel: 604 732-8821
Fax: 604 732-4801
E-mail: wjgroup@weir-jones.com
Web: www.weir-jones.com
ISO 9001:2000 Registered
th
June 17 , 2005

Advertisement

Table of Contents
loading

Summary of Contents for OPTICOM MIL-STD-810F

  • Page 1 Opticom Technologies Inc. SAE J1455 and MIL-STD-810F Vibration Testing of Model CC-02-4.3 CCTV Camera Prepared by: Weir-Jones Engineering Consultants Ltd. 2040 West 10th Avenue Vancouver, B.C. V6J 2B3 Tel: 604 732-8821 Fax: 604 732-4801 E-mail: wjgroup@weir-jones.com Web: www.weir-jones.com ISO 9001:2000 Registered...
  • Page 2 AUTHORIZATION The work described in this report was authorized by David Boyd of Opticom Technologies Inc. on June10 , 2005. The report was prepared by Paul Chong, P.Eng. Paul Chong, P.Eng. Project Engineer Dated at Vancouver, June 17 , 2005.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION ............1 VIBRATION PROFILES .
  • Page 4: Introduction

    On June 10 , 2005 Weir-Jones Engineering Consultants Ltd. (WJEC) was retained by Opticom Technologies Inc. to perform a set of vibration tests on its Model CC-02-4.3 CCTV camera. The primary objective in testing the camera was to verify its structural integrity. This was done by subjecting the unit to the worst-case vibrational stresses expected in its application environment.
  • Page 5 Blue - Vibration profile Red - Upper and lower limits of frequency and acceleration (equivalent to ±3dB) Figure 1: Graphical plot of the SAE J1455 Sinusoidal vibration profile intended for equipment to be mounted on truck chassis. Blue - Vibration profile Red - Upper and lower limits of frequency and amplitude (equivalent to ±6dB) Figure 2:...
  • Page 6: Vibration Test Equipment

    VIBRATION TEST EQUIPMENT The equipment required for the vibration tests was a shaker, a vibration controller and two feedback accelerometers (see Figure 3). The specifications of the equipment used are as follows. Shaker: Manufacturer: Ling Dynamic Systems (LDS) Model: V722 Rated Force: 750 lbf.
  • Page 7 As the vibration shaker was designed to translate in the vertical direction only, a set of Aluminum mounting fixtures were used to position the CCTV camera in its two mutually perpendicular axes (Vertical and Transverse) as shown in Figures 4A and 4B. Feedback accelerometers Figure 4A: Vertical orientation mounting of the CCTV camera.
  • Page 8: Results

    RESULTS Sinusoidal Vibration Test The graphical results of the Sinusoidal vibration tests for the Model CC-02-4.3 CCTV camera are shown in Appendix 2 located in the back of this report. The interpretation of the lines on each graphical result is as follows: Line Colour Description Frequency limits and...
  • Page 9 No degradation in the quality of the video produced by the camera was noticeable during or after the tests. Therefore the Model CC-02-4.3 CCTV camera has passed the U.S. Highway Truck Random vibration test in accordance with Method 514.5 of the MIL-STD-810F (January 2000) Standard. Weir-Jones Engineering Consultants Ltd. 30144-REP-001-0.wp9...
  • Page 10: Appendix 1: Calibration Certificates

    APPENDIX 1: Calibration Certificates Weir-Jones Engineering Consultants Ltd. 30144-REP-001-0.wp9...
  • Page 11 Weir-Jones Engineering Consultants Ltd. 30144-REP-001-0.wp9...
  • Page 12 Weir-Jones Engineering Consultants Ltd. 30144-REP-001-0.wp9...
  • Page 13 Weir-Jones Engineering Consultants Ltd. 30144-REP-001-0.wp9...
  • Page 14 Weir-Jones Engineering Consultants Ltd. 30144-REP-001-0.wp9...
  • Page 15: Appendix 2: Sinusoidal Test Results

    APPENDIX 2: Sinusoidal Test Results Weir-Jones Engineering Consultants Ltd. 30144-REP-001-0.wp9...
  • Page 16 Figure A2-1: Graphical profiles of the Sinusoidal vibration test for the Model CC-02-4.3 CCTV camera mounted in the Vertical orientation. Figure A2-2: Graphical profiles of the Sinusoidal vibration test for the Model CC-02-4.3 CCTV camera mounted in the Transverse orientation. Weir-Jones Engineering Consultants Ltd.
  • Page 17: Appendix 3: Random Test Results

    APPENDIX 3: Random Test Results Weir-Jones Engineering Consultants Ltd. 30144-REP-001-0.wp9...
  • Page 18 Figure A3-1: Graphical profiles of the Random vibration test for the Model CC-02-4.3 CCTV camera mounted in the Vertical orientation. It should be noted that the amplitude between 10 and 20 Hz had been increased slightly in order to compensate for the lighter weight aluminum fixture. The resultant shaker output however still matches with the required profile as defined by the MIL standard.