Table of Contents

Advertisement

Quick Links

"MEETS
1990 EPA STANDARDS"
I
I
@
I
I
I
I
,--
--..
,
!
Ov.
0
MODEL 41
MODEL 50
FEATURES
PREPARATION
INSTALLATION
OPERATION
MAINTENANCE
SAFETY
Contact your Insurance company for coverage and Installation Inspection
SAFETY NOTICE
If this heater Is not properly Installed, a house fire may result. For your safety, follow
the Installation directions. Contact local building or fire officials about restrictions and
Installation inspection requirements in your area.
tl0
L
This symbol on the nameplate means the product is Listed by Underwriters Laboratories. Inc.
\'.!.bJ
File No. MH15931, MH15933, UL Standard No. 1482
Manufactured by New Buck Corp. - Spruce Pine, NC 28777 - EFFECTIVE
6/1/90
PN-PI 4106608

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 50 and is the answer not in the manual?

Questions and answers

Summarization of Contents

SECTION I: Introduction and Features
Physical Features
Diagram and identification of the heater's physical components.
Room Heater Features and Controls
Detailed descriptions of the heater's components and operating controls.
EPA Compliance Status and Fuel Selection
Heater's EPA status, catalyst information, and fuel recommendations.
Achieving Catalytic Lightoff
Guidance on reaching optimal temperatures for catalytic ignition.
Catalytic Monitoring and Draft
Procedures for monitoring catalyst operation and maintaining proper draft.
Ash Removal
Instructions for safely removing ashes from the heater firebox.
SECTION II: Masonry Insert Installation
Installation Precautions
Safety and performance guidelines for masonry insert installation.
Minimum Clearances and Floor Protection
Specifies required distances and floor protector needs for inserts.
Required Fireplace Dimensions
Dimensions for fireplace opening and hearth for inserts.
Installation Preparation
Steps to prepare the fireplace and heater for installation.
Heater Preparation and Positioning
Steps for preparing the unit and positioning it in the fireplace.
Mounting Trim Panels
Instructions for attaching trim panels to the heater.
Final Check for Masonry Insert
Post-installation checks for masonry insert installation.
SECTION III: Residential Freestanding Heater Installation
Installation Precautions
Guidelines for freestanding stove venting and installation.
Model 41 Clearances and Floor Protection
Specific clearance and floor protection for Model 41.
Model 50 Clearances and Floor Protection
Specific clearance and floor protection for Model 50.
Tools for Installation
List of tools recommended for heater installation.
Preparing Stove and Room Location
Steps to prepare the heater and its installation area.
Determining Chimney Location
Guidance on locating the chimney exit for various setups.
Wall Exit Installation Procedures
Procedures for exiting the flue through walls.
Final Check for Wall Exit
Final checks after wall exit installation.
SECTION IV: Mobile Home Installation
Mobile Home Installation Warnings
Critical safety warnings specific to mobile home installations.
Model 41 Parts & Chimney Systems
Required parts and chimney systems for Model 41.
Model 50 Parts & Chimney Systems
Required parts and chimney systems for Model 50.
Model 50 Clearances & Floor Protection
Clearance and floor protection for Model 50 with specific chimneys.
Preparing Stove and Location for Mobile Home
Steps for preparing heater and room for mobile home setup.
Chimney Location for Ceiling Exit
Guidance for ceiling exit chimney location in mobile homes.
Final Check for Mobile Home Installation
Final checks after mobile home installation.
SECTION V: Wood Heater Safety
Wood Heater Safety Overview
Essential safety hazards and precautions for wood heaters.
SECTION VI: Operation
Building a Fire
Step-by-step guide to starting and managing a fire efficiently.
Model 41 and 50 Burn Rates
Burn rate settings and wood loading procedures for both models.
Operating and Safety Hints
Tips for efficient operation, safety, and catalyst management.
Burning Qualities of Wood
Guide to different wood types and their burning characteristics.
Helpful Hints
Advice on paint curing, thermostat use, and fire burning tips.
SECTION VII: Preventive Maintenance and Parts Replacement
Chimney and Heater Cleaning
Instructions for chimney inspection and heater cleaning.
Catalytic Inspection
Methods for inspecting the catalytic combustor's condition.
Catalytic Replacement
Procedures for replacing the catalytic combustor.
Door Seal Inspection and Replacement
Checking and replacing door gaskets for proper sealing.
SECTION VIII: Catalytic Troubleshooting
Definitions
Glossary of terms related to catalytic heaters.
Introduction to Catalytic Heaters
Overview of catalytic heater technology and benefits.
How Catalytic Combustors Work
Explanation of the catalytic combustor's function and advantages.
Operating a Catalytic Heater
Key considerations for operating catalytic heaters effectively.
Possible Problems with Catalytic Heaters
Common issues encountered with catalytic heaters and their causes.
Troubleshooting Heater Problems
Solutions for issues like sluggish performance and low efficiency.
Troubleshooting Chimney Problems
Solutions for chimney-related issues like creosote and draft.
Troubleshooting Combustor Problems
Solutions for combustor-specific issues like plugging and deactivation.
Combustor-Related Problems
Detailed solutions for combustor issues like peeling, deactivation, and cracking.
Limited Warranty
Warranty Coverage and Claim Procedure
Details on warranty coverage, exclusions, and how to file a claim.

Table of Contents