INSTALLATION
Continued
BUILT-IN FIREPLACE
INSTALLATION
Built-in installation of this fireplace involves
installing fireplace into a framed-in enclo-
sure. This makes the front of fireplace flush
with wall. An optional brass trim kit acces-
sory is available (see Accessories, page 27).
Brass trim will extend past sides of fireplace
approximately 1/2 inch. This will cover the
rough edges of the wall opening. If install-
ing a built-in mantel above the fireplace you
must follow the clearances shown in Figure
11, page 10. Follow the instructions below
to install the fireplace in this manner.
Actual
Height
26"
3
Front Width
26
1
Depth
9
/
Bottom
3/4"
1. Frame in rough opening. Use dimen-
sions shown in Figure 8 for the rough
opening.
If installing in a corner, use dimensions
shown in Figure 9 for the rough open-
7
ing. The height is 26
same as the wall opening above.
10 1/2"
26 7/8"
26 7/8"
Figure 8 - Rough Opening for Installing in
Wall
36 5/8"
26 7/8"
51 3/4"
Figure 9 - Rough Opening for Installing in
Corner
104060
2. If installing GA3400(T) blower acces-
sory, do so at this time. Follow instruc-
tions included with blower accessory.
Note: If not installing blower acces-
sory, you may wish to run electrical
wiring to your fireplace for future
blower installation (see Accessories,
page 27) Use only approved three-wire
electrical wiring.
WARNING: If pre-wiring, do
not connect wiring to any electri-
cal source at this time.
Install fireplace electrical outlet
and connect wiring to outlet be-
fore connecting to electrical
source. The fireplace electrical
outlet is included with the
Framing
GA3400(T) blower accessory.
7
26
/
"
Only use the fireplace electrical
8
outlet
7
/
"
26
/
"
4
8
GA3400(T) blower accessory.
1
"
10
/
"
2
2
Note: A qualified installer should make
3/4"
all electrical connections.
3. Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the manual shutoff valve.
The flexible gas line must be the last
item installed on the gas piping.
/
" which is the
8
4. If you have not assembled firebox, fol-
low instructions on page 4.
Nails or
Wood
Screws
3/4" Off
The Floor
Minimum
25 7/8"
Figure 10 - Attaching Fireplace to Wall
Studs
OWNER'S MANUAL
supplied
with
the
Nailing
Flanges
9
5. Carefully set fireplace in front of rough
opening with back of fireplace inside
wall opening.
6.
Attach flexible gas line to fireplace gas
regulator. See Connecting Fireplace to
Gas Supply, page 15.
7. Bend four nailing flanges on outer cas-
ing with pliers (see Figure 10).
8. Attach fireplace to wall studs using
nails or wood screws through holes in
nailing flange.
9. Check all gas connections for leaks. See
Checking Gas Connections, page 16.
10. If using optional brass trim kit, install
the trim after final finishing and/or
painting of wall. See instructions in-
cluded with brass trim accessory for at-
taching brass trim.
IMPORTANT: When finishing your fire-
box, combustible materials such as wall
board, gypsum board, sheet rock, drywall,
plywood, etc. may be butted up next to the
sides and top of the firebox. Combustible
materials should never overlap the firebox
front facing.
WARNING: Do not allow any
combustible materials to overlap
the firebox front facing.
IMPORTANT: Noncombustible materials
such as brick, tile, etc. may overlap the front
facing, but should never cover any neces-
sary openings like louvered slots.
WARNING: Do not allow non-
combustible materials to cover
any necessary openings like lou-
vered slots.
WARNING: Never modify or
cover the louvered slots on the
front of the firebox.
WARNING: Use only non-
combustible mortar or adhesives
when overlapping the front fac-
ing with noncombustible facing
material.