Connecting To Gas Supply - Desa Vanguard VMH10TPA Owner's Operation And Installation Manual

Desa owner's operation and installation manual vent-free propane/lp gas compact classic hearth fireplace vmh10tpa
Table of Contents

Advertisement

VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE
INSTALLATION
Continued
Attaching Wood Base to Solid
Floor
For attaching base to solid floors (concrete
or masonry)
Note: Floor anchors and mounting screws
are in hardware package. The hardware pack-
age is provided with fireplace.
1. Drill holes at marked locations using
5/16" drill bit. For solid floors (concrete
or masonry), drill at least 1" deep.
2. Fold floor anchor as shown in Figure 21.
3.
Insert floor anchor (wings first) into
hole. Tap anchor flush to floor.
4. Insert mounting screws through base
and into floor anchors.
5. Tighten screws until base is firmly fas-
tened to floor.
Figure 21 - Folding Anchor
CONNECTING TO GAS
SUPPLY
WARNING: A qualified ser-
vice person must connect fire-
place to gas supply. Follow all
local codes.
CAUTION: Never connect fire-
place directly to the propane/LP
supply. This fireplace requires
an external regulator (not sup-
plied). Install the external regula-
tor between the fireplace and pro-
pane/LP supply.
The installer must supply an external regu-
lator. The external regulator will reduce
incoming gas pressure. You must reduce
incoming gas pressure to between 11 and
14 inches of water. If you do not reduce
incoming gas pressure, fireplace regulator
damage could occur. Install external regu-
lator with the vent pointing down as shown
in Figure 22. Pointing the vent down pro-
tects it from freezing rain or sleet.
VMH10TPA
®
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
or greater
proper gas volume to fireplace. If
pipe is too small, undue loss of
pressure will occur.
Propane/LP
Supply Tank
Figure 22 - External Regulator with Vent
Pointing Down
Approved Flexible
Gas Line
Figure 23 - Gas Connection
* Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer.
See Accessories, page 27.
diameter to allow
External Regulator
Vent Pointing Down
A.G.A. Design-Certified Manual
Shutoff Valve With 1/8" NPT Tap*
3" Minimum
Pipe Nipple Cap Tee Joint
14
Installation must include a manual shutoff
valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
fireplace (see Figure 23).
IMPORTANT: Install main gas valve
(manual shutoff valve) in an accessible
location. The main gas valve is for turning
on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.
CAUTION: Use pipe joint seal-
ant that is resistant to liquid pe-
troleum (LP) gas.
We recommend that you install a sediment
trap in supply line as shown in Figure 23.
Locate sediment trap where it is within
reach for cleaning. Install in piping system
between fuel supply and heater. Locate sedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into fireplace controls. If sediment
trap is not installed or is installed wrong,
fireplace may not run properly.
From
External
Regulator
(11" W.C.
to 14" W.C.
Pressure)
Sediment Trap
104407