Scotsman FME24RLM Service Manual page 19

Double system rl
Table of Contents

Advertisement

SERVICE DIAGNOSIS
Symptom
Water Leak
Uses too much water
Excessive ice meltage
Machine makes too much noise
Possible Cause
Drain plugged up
Tubing cracked
Condensation on drain tubing
Hose off
Reservoir cover off
Reservoir cracked
Evaporator water seal leaks
Reservoir float valve leaks thru
Bin drain clogged
Improper installation of drains,
they are connected.
Poor fit between bin door and door
frame
Evaporator coated internally with
minerals
Motor bearings dry
November 2000
Page 19
Double System RL
Probable Correction
Clean out drain
Replace tubing
Insulate tubing
Reattach hose
Return cover to reservoir
Replace reservoir
Check base of evaporator & drip
pan. If the seal leaks, shut off the
water, remove the auger, replace
the water seal. Check gear motor
for water infiltration.
Replace float valve or seat
Clean out bin drain.
Drains must be separate.
Adjust or replace
Clean with Scotsman Ice Machine
Cleaner
Oil or replace motor