1210 System Board, Pc Card/Expresscard Slots Assembly And Interposer Card - IBM THINKPAD T60 Hardware Maintenance Manual

14.1-inch and 15.0-inch
Hide thumbs Also See for THINKPAD T60:
Table of Contents

Advertisement

Removing and replacing a FRU
1210 System board, PC Card/ExpressCard slots assembly and
interposer card
For access, remove these FRUs, in order:
v "1010 Battery pack" on page 63
v "1020 Ultrabay Slim device" on page 64
v "1030 Hard disk drive cover, hard disk drive, and hard disk drive rubber rails"
v "1040 Palm rest or palm rest with fingerprint reader" on page 67
v "1050 DIMM" on page 74
v "1060 Keyboard" on page 75
v "1070 Modem daughter card (MDC-1.5)" on page 77
v "1080 PCI Express Mini Card for 802.11 a/b/g wireless LAN" on page 79
v "1100 PCI Express Mini Card for wireless WAN" on page 83
v "1120 Keyboard bezel and wireless WAN antenna cable (AUX)" on page 86
v "1130 Fan assembly" on page 89
v "1140 CPU" on page 93
v "1150 LCD assembly" on page 94
v "1160 Base cover" on page 98
v "1190 SIM card slot" on page 106
v "1200 Structure frame" on page 107
114
MT 1951, 1952, 1953, 1954, 1955, 1956, 2007, 2008, 2009, 2613, 2623, and 2637
Important notices for handling the system board
When handling the system board, bear the following in mind.
v At every point in the process, be sure not to drop or stack the system
board.
v The system board has an accelerometer, which can be broken by applying
several thousands of G-forces.
Note: Dropping a system board from a height of as little as 6 inches so
that it falls flat on a hard bench can subject the accelerometer to as
much as 6,000 G's of shock.
v Be careful not to drop the system board on a bench top that has a hard
surface, such as metal, wood, or composite.
v If a system board is dropped, you must test it, using PC-Doctor for DOS, to
make sure that the HDD Active Protection still functions (see below).
Note: If the test shows that HDD Active Protection is not functioning, be
sure to document the drop in any reject report, and replace the
system board.
v Avoid rough handling of any kind.
v If you put a system board down, be sure to put it only on a padded
surface such as an ESD mat or conductive corrugated material.
After replacing the system board, run PC-Doctor for DOS to make sure that
HDD Active Protection still functions. The procedure is as follows:
1. Place the computer on a horizontal surface.
2. Run Diagnostics --> ThinkPad Devices --> HDD Active Protection Test.
Attention: Do not apply physical shock to the computer while the test is
running.
on page 65