Download Print this page

TW SOLAR TW410MAP-108-H Installation Manual

Photovoltaic module

Advertisement

Photovoltaic Module Installation Manual for
TW solar energy Co., Ltd

Advertisement

loading
Need help?

Need help?

Do you have a question about the TW410MAP-108-H and is the answer not in the manual?

Questions and answers

Summary of Contents for TW SOLAR TW410MAP-108-H

  • Page 1 Photovoltaic Module Installation Manual for TW solar energy Co., Ltd...
  • Page 2 When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge. TW solar energy Co., Ltd...
  • Page 3: Table Of Contents

    CONTENTS Purpose of this Manual ....................... 3 Disclaimer ........................... 3 Safety & Transport ........................4 Mechanical Installation....................... 7 Electrical Installation ........................ 14 Grounding ..........................16 Bypass Diodes and Block Diodes ..................... 17 Maintenance..........................18 TW solar energy Co., Ltd...
  • Page 4: Purpose Of This Manual

    ⚫ This manual applies exclusively to the solar photovoltaic module (here in after referred to as Module) of TW solar energy Co., Ltd. (here in after referred to as TW). The contents of this manual involve the installation methods, operation safety and maintenance information of TW’s Modules.
  • Page 5: Safety & Transport

    Do not use sharp objects with Modules Do not stamp on Modules Do not touch Modules with bare or dirty Do not pile up Modules on uneven ground Do not drop or throw Modules hands TW solar energy Co., Ltd...
  • Page 6 5. During the stacking of the Modules, the 6. One module shall be handled by two outer packing box can be stacked not people together. exceed the maximum layer allowed .(n=2 means it is allowed to stack for at most two layers.) TW solar energy Co., Ltd...
  • Page 7 Figure 2 Lifting Schematics ⚫ It is prohibited to stack the Modules in the project site. ⚫ During the transportation at the project site, the Modules shall not be stacked, but only allowing for one layer in transportation. TW solar energy Co., Ltd...
  • Page 8 6. Before the unpacking, it is necessary to carefully check the product information on the carton box, and carefully read the unpacking instruction; 7. Every module shall be carried by two people. When carrying the module by two people, it is prohibited to pull the junction box. TW solar energy Co., Ltd...
  • Page 9: Mechanical Installation

    Mounting Tilt Angles 0°-15° 15° 15°-25° Local latitude 25°-30° Local latitude + 5° 30°-35° Local latitude + 10° 35°- 40° Local latitude + 15° >40° Local latitude + 20° Table 1 Mounting Tilt Angle of Modules TW solar energy Co., Ltd...
  • Page 10 ⚫ When the module is installed on the supporting column, it is necessary to ensure the supporting column and module installation structure is capable of withstanding the expected local wind. TW solar energy Co., Ltd...
  • Page 11 Location Dimension Module Type side/Rear side, K (mm) (mm) γm=1.5(Pa) TW***MAP-108-H 1722*1134*35 380~480 3600/1600 TW***MAP-144-H 2278*1134*35 520~620 3600/1600 TW***MCP-132-H 2384*1303*35 546~646 3600/1600 Note: Test load = γm( × design load safety factors) TW solar energy Co., Ltd 10 11 09...
  • Page 12 TW solar energy Co., Ltd...
  • Page 13 Flat washer Spring washer Material: stainless Steel material: stainless steel Material: stainless steel Material: stainless steel Size: M8 Size: M8 Size: M8 Size: M8 The range of torque for screw tightening is 14N.m to 20N.m. TW solar energy Co., Ltd...
  • Page 14: Electrical Installation

    When connected in parallel, the current output is equal to the sum of each string’s current ⚫ (as shown in Figure 6). Fuse is necessary for each module string. Take reference to the local regulation. Recommended maximum parallel Modules configurations: Fuse rating/ (1.25* short-circuit current). TW solar energy Co., Ltd...
  • Page 15 ⚫ Make sure the electric components such as the connectors and inverters are off-state during the installation. To reduce lightning damage, the loop area should be kept as small as possible when laying cables. It is recommended to use fuses in each string. TW solar energy Co., Ltd...
  • Page 16: Grounding

    Spring washer(SS) Spring washer Flat washer Flat washer(SS) Star washer Star washer(SS) Frame Bolt (M3, SS) Frame Flat washer(SS) Grounding Lug Cup washer(SS) Copper wire Spring washer(SS) Grounding Bolt (M3.5, SS) cable Figure 7 Figure 8 TW solar energy Co., Ltd...
  • Page 17: Bypass Diodes And Block Diodes

    This should be processed by the professionals. In a system with batteries, if the controller doesn’t have the function of backswing protection, block diodes installed between the battery and the Module can prevent the reverse current from damaging the Module. TW solar energy Co., Ltd...
  • Page 18: Maintenance

    When exposed to the sunshine, the Modules will produce high voltage. The repair work must be carried out by professionals. Warning: Shut down the system before any electric repair. Improper maintenance may cause electric shock or fir TW solar energy Co., Ltd...
  • Page 19 Annex 1 Electrical Parameter PRODUCT:TW***MAP-144-H Maximum Power-P (Wp): Open Circuit Voltage-V 50.54 50.70 50.94 Short Circuit Current-I 13.73 13.81 13.87 Maximum Power Voltage-V 42.35 42.64 42.93 Maximum Power Current-I 12.87 12.90 12.93 Maximum System Voltage (V) 1500 1500 1500 Max Series Fuse Rating (A) PRODUCT:TW***MAP-108-H Maximum Power-P (Wp):...