NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices
to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which
results in an "electrolysis" effect occurring in the fountain. This may result in water which has a
metallic taste to it or has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the
installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation.
Any drain fittings provided by the installer should be made of plastic which will electronically isolate
the fountain from the remainder of the building's plumbing circuits.
EDFPBM114WS
INSTALLATION, CARE & USE MANUAL
Refrigerated fountains with FLEXI-GUARD
and EZH
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.
Service to be performed by authorized service personnel only.
EDFPBM114WS-F
O
Bottle Filler
®
2
LZWS-EDFPBM114K
Page 1
1000002503 (Rev.A - 04/15)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SWIRLFLO LZWS-EDFPBM114K and is the answer not in the manual?

Questions and answers

Summarization of Contents

Installer Guidance and Safety
Installation Safety and Code Compliance
Review installation instructions and ensure conformity to all plumbing, electrical, and other applicable codes.
Service and Reference Information
Leave installation instructions in the bag for future reference; service by authorized personnel only.
Electrolysis and Grounding Advisory
Note on potential electrolysis effect from grounding to water lines and recommended plastic drain fittings.
Installation Preparation and Materials
Required Tools and Additional Materials
Lists special tools and necessary additional materials not provided with the unit.
Water Supply and Tube Routing
Instructions for making water supply connections and routing tubing for filtration.
Assembly and Final Installation Steps
Electrical and Waste Connections
Details on installing reset switch, waste tubes, and making final water supply connections.
Dispensing and Stream Adjustment
Verify dispensing, check stream height, and adjust regulator if needed.
Control Board Programming and Settings
Verify Control Board Software
Steps to verify the control board software designation (BF11).
Filter Monitor and IR Sensor Configuration
Procedures for resetting the filter monitor and setting the IR sensor range.
Unit Type and Bottle Counter Settings
Configure unit type (refrigerated/non-refrigerated) and reset the bottle count.
Filter Capacity Setting
Instructions on how to select and set the filter capacity (e.g., 3000GAL or 6000GAL).
Parts, Troubleshooting, and Maintenance
Parts List and Replacement Kits
Comprehensive lists of fountain components and specific replacement kits for bottle fillers.
Troubleshooting Orifice Assembly Issues
Guidance on removing mineral deposits from the orifice assembly to ensure proper water flow.
Quick Connect Fittings Operation
Instructions for connecting and disconnecting water lines using quick connect fittings.

Table of Contents