  • Page 1 2019 SOLID FUEL HYDRO STOVE / COOKER USERGUIDE TRUVA & ABAN Rev.No 2019.1.1...
  • Page 3: Table Of Contents

    Contents INTRODUCTION .................... 4 IMPORTANT NOTICE ................5 1.1. General Safety Warnings ..............5 1.2. Operating Warnings ................6 TECHNICAL SPECIFICATIONS ..............6 FUEL SPECIFICATION ................9 INSTALLATION ................... 11 4.1. Operating Environment ..............11 4.2. Electrical Connections ..............12 4.3.
  • Page 4 OVEN HANDLING AND COOKING INSTRUCTIONS ......... 25 USED HARDWARES OF STOVE ............. 27 7.1. Thermostat Use And Specifications ..........27 7.2. Use Of Mechanical Air Flap ............28 7.3. Use Of Shaking Rods ..............29 7.3.1. Cleaning The Grat ..............29 7.3.2.
  • Page 5: Introduction

    INTRODUCTION Dear Friend of İFYIL; İFYIL TERMO İKLİMLENDİRME SAN. Ve TİC. LTD. ŞTİ. we manufacture the most efficient hydro stoves with utmost care for our distinguished customers. So, please read this userguide carefully before starting to use our stove and keep it as a reference in any case. Information This symbol high lightens the significant details for correct usage of stove.
  • Page 6: Important Notice

     Spare parts should only be used by the recommended manufacturer.  IFYIL hydro stoves must be installed according to the installation schema.  During the burning of your stove, the outer surfaces of the stove (doors and glasses, exterior plates, stove base, etc.), heating surface (casting etc.), metal handles, pipes and the inside of the oven should be careful as it is hot.
  • Page 7: Operating Warnings

    Assembly of İFYIL stoves and fireplaces; Electrical connections and installation should be done in accordance with the scheme.  IFYIL stoves are suitable for home, office and interior. IFYIL stoves balcony, warehouse, bathroom etc. should not be installed in such areas. ...
  • Page 8 Technical Specifications Measured Values Device type/model; Solid Fuel Hydro Stove ROASTER SUPERNOVA SAUNA HAMMAM STAR Wood Nominal heat output Briquette Coal 34,5 Wood Water heating power Briquette Coal Wood Space heating power Briquette Coal Efficiency 84,93 Fuel type Wood, Briquette, Coal Fuel loading zone Front loading Top loading...
  • Page 9 operating Permissible maximum pressure Test pressure Boiler water volume Recommented flue pipe draft Weight Stove Dimensions Stove 650x745x1146 650x745x1146 650x745x880 650x745x880 1158x733x924 (Width x Depth x Height) Oven 320x480x175 367x495x260 Water round-trip inch connections Expansion Connections tank inch connections Chimney Ø...
  • Page 10: Fuel Specification

    3. FUEL SPECIFICATION In order to achieve the maximum performance of IFYIL stoves; Calorific value and properties of the fuel to be used is very important. The calorific value of the fuel depends on the humidity and density. The tendency of the moist fuel to burn is low.
  • Page 11 For Briquette; The briquettes to be used must have a moisture content of less than 12% and should be stored in a dry place. The use of damp briquettes may cause fire in the chimney due to accumulation of soot in the chimney. For Coal;...
  • Page 12: Installation

    4. INSTALLATION  This stoves product for houses, offices and internal places.  İFYIL stove should not be installed in areas such as balconies, bathrooms, warehouses. In case of use outside of the interior, our company accepts no responsibility for the problems related to heating. ...
  • Page 13: Electrical Connections

    If the stove is installed next to flammable wall, isolation for the wall should be done.  If the base where the stove is to be installed is made of flammable materials. If the stove is put on flammable material, suitable isolation must be done.
  • Page 14: Plumbing Connections

    4.3. Plumbing Connections  120 cm and longer radiator must be connected to the installation with a reverse connection.  Definitly should had fill and drain valve in the installation  The safety valve is mounted on the body.  Boiler lit (off) the water pressure should be in the range of 1-1,5 bar.
  • Page 15  It is recommended to install a thermostatic valve in the radiators to ensure that the room temperature can be kept to the desired degree and to provide high comfort at low cost.  EU standards. Half of the installation should be 1 '' (32 boiler installations), half 3/4 '' (25 installation booths).
  • Page 16: Plumbing Schema

    4.3.1. Plumbing Schema The image of the Avanos model is included in the schema. The distance between the connections of Toros, Canik and Ilgaz models may vary from product to product.
  • Page 17 Model: Star...
  • Page 18: Open Expansion Tank

     Safety pipes must be installed without any downsizing and always rising towards the expansion vessel. It is mandatory to use open expansion tank in IFYIL solid fuel stove and cooker. In these systems, closed expansion cannot be used. Otherwise, IFYIL will not accept any liability.
  • Page 19: Plumbing Water Specification

    4.3.3. Plumbing Water Specification Properties that should be in boiler water; EN 12953-10 “Shell boilers- Part 10: Requirements for feedwater and boiler water quality” must comply with the standard. In the boiler and heating system, water in quality of drink water should be used in order to prevent damage caused by corrosion.
  • Page 20: Chimney Instructions

    4.5. Chimney Instructions The main cause of the chimney fire;   Improper selection or pipe that dust is flammable fuel.  In the event of appropriate conditions can cause fires ignite in the ducts. Ways of avoiding them;  ...
  • Page 21: Smoke Pipe Instructions

     Chimney cap should be used to prevent the flow into the chimney flue repercussions of windy weather and rain.  Concrete blocks are affected by temperature changes, concrete flat roof which is in direct contact with the air must be absolutely isolated. ...
  • Page 22: Suitable Shapes Of Chimney And Connections

     Please take care of flue pipe standard’s sizes, the problems in case of using nonstandard sizes will not be under our responsibility.  Sediment formation in chimneys causes the chimney diameter to decrease and the combustion efficiency in the stove decreases. The pipes and flue must be cleaned before the stove is installed.
  • Page 23 **stoves shown in Suitable and unsuitable chimney shapes pictures are representation HOUSES OFFICES OBEYİNG ABOVE MENTIONED STANDARDS ARE POTENTIAL FOR FIRE AT ANYTIME AND CARBON MONOXIDE (CO) GAS LEAKAGE. PLEASE FOLLOW THE ABOVE MENTIONED INSTRUCTİONS! CLIENT ACCEPTS THAT; SUCH MANUFACTURER DOES NOT HAVE ANY RESPONSIBILITY IN ANY POSSIBLE DAMAGES CLIENT NOT FULFILLING ABOVE MENTIONED REQUIREMENTS IN SCHEMAS CANNOT CLAIM ANY RIGHT OR COMPENSATION.
  • Page 24: Operating

    5. OPERATING 5.1. Pre-Operation Warnings  Water level of expansion tank should be checked once a week. Water level of expansion tank appers half level before burning  Chimney and pipe connections must be checked for clogging and leakage.  Combustion chamber, ashpit and air intake must be cleaned.
  • Page 25: Combustion Control

    cleaning is carried out with the swinging rod located on the right side of the stove to increase the efficiency and it is ensured that the fuel to be loaded is better to burn by taking in the air. Flared burning allows continuity of burning. This type of combustion is the recommended combustion mode to achieve more efficient combustion.
  • Page 26: Initial Ignition

    Combustion air intake is controlled by mechanical flap. In addition, thanks to the shaking arm, the ash is cleaned and the passage of the combustion air to the combustion chamber is facilitated. Primary air intake is provided by a mechanical air trap located behind the sole for the initiation and continuity of the burn.
  • Page 27  Do not put oven tray on the base. Heat can dammage the bottom of the oven.  Do not use the product with the oven door window removed or broken.  When the food is placed in the oven the temperature may drop by about 20- 30 degrees.
  • Page 28: Used Hardwares Of Stove

    7. USED HARDWARES OF STOVE 7.1. Thermostat Use And Specifications Thermostat specification; Tolerance : ±1 Operating Interval : °C 0-120 Storage Temperature Range : °C (-40) - (125) Long-term deviation : °C / year <0.04 Dimensions : 65x33x74 Thermostat to adjust the operating temperature in the stove; ...
  • Page 29: Use Of Mechanical Air Flap

    7.2. Use Of Mechanical Air Flap  The air clap of the stove works at 40-80⁰C.  By adjusting the air clap to the right of the stove you can adjust the water temperature in the specified range to determine the maximum temperature at which the stove will go to sleep mode.
  • Page 30: Use Of Shaking Rods

    7.3. Use Of Shaking Rods 7.3.1. Cleaning The Grat Model: Roaster / Supernova / Sauna / Hammam The shaking rod on the left side of the stove is removed from the placed position and pulled to the right to the horizontal position. The fuel in the form of ash and ashes on the grate is discharged to the ash pit.
  • Page 31: Ash Eliminate

    7.3.2. Ash Eliminate Model: Roaster / Supernova / Sauna / Hammam The shaking rod on the left side of the stove is not removed from the placed position and pulled to the right to the horizontal position. The fuel in the form of ash on the grate is discharged to the ash pit.
  • Page 32: Use Of Smoke Flap (Star)

    7.4. Use Of Smoke Flap (Star) Smoke flaps in the stove during the discharge of the smoke generated as a result of firing by changing the way to achieve different functions, the curtains to provide the closure of the smoke paths. The smoke flap lever position for each function is shown below.
  • Page 33: Main Parts And Dimensions

    8. MAIN PARTS AND DIMENSIONS ROASTER...
  • Page 34 SUPERNOVA...
  • Page 35 SAUNA...
  • Page 36 HAMMAM...
  • Page 37 STAR...
  • Page 38: Pump Warning Lamp

    9. PUMP WARNING LAMP DETAILED LED COLOUR MEAN DESCRIPTION The pump is operating Normal Operation normally. Solid Green Light Pump will try to take the air in the system for 10 minutes. The pump then this process will not work if the maximum speed;...
  • Page 39: Maintenance And Cleaning

    10. MAINTENANCE and CLEANING All cleaning of your stove, while your stove is not lit (when cold case) and make the electrical connection closed position. ROASTER  Please take out top cast part (1) and clean surface with help of brush provided with stove.
  • Page 40 SUPERNOVA  Please take out top cast part (1) and clean surface with help of brush provided with stove.  The surface inside the upper door (1) should be cleaned with cleaning brush.  The surface inside the front door (2) should be cleaned with cleaning brush.
  • Page 41 HAMMAM  Please take out top cast part (1) and clean surface with help of brush provided with stove.  The surface inside the upper door (2) should be cleaned with cleaning brush.  Please clean both sides of grate (3). ...
  • Page 42 STAR  Areas that appear when the boot lid (1) is opened must be cleaned with the help of a cleaning brush.  The flue outlet should be cleaned with the helpof a cleaning brush by lifting the upper casting (2) of the furnace. ...
  • Page 43: Problems, Causes And Solutions

    11. PROBLEMS, CAUSES and SOLUTIONS PROBLEM POSSIBLE CAUSE SOLUTIONS  There is inefficient  Inadequate air combustion  Maintain and clean the chimney. combustion and when the loading  Inadequate chimney draught  A new chimney suitable for the door is opened the flames are needs of the system is required.
  • Page 44  Incorrect chimney selection  The household heat needs to be checked and, if necessary, a suitable stove should be selected.  Isolation of the room used is not good  Wrong product selection  Even though the boiler is ...
  • Page 45  Pump circulation is not  There is an air jam in the  The air in the pump will be working pump. automatically thrown away.  The air inside the pump can  There may be an air jam in ...
  • Page 46: Significiant Instructions For Effective Using

    12. SIGNIFICIANT INSTRUCTIONS for EFFECTIVE USING  Ensure that the ashtray and the combustion chamber are clean before firing the stove.  Please clean the inside of the glazed models with the help of cleaner and outside with the clean cloth. ...
  • Page 47: Suggestions And Feedback

    Service Calls For technical service calls, please visit www.ifyil.com.tr Any right cannot be claimed due to the changes or modifications or wrong use of spare parts. IFYIL original spare parts must be used for any permitted change of spare part.
  • Page 48: Certificate Of Warranty

    Kavak OSB Kavak/ Production Date: SAMSUN/TÜRKİYE Warranty Time: Two Years Phone: +90 (362) 266 94 43 Max Reperation Time: Twenty Working Days Fax: +90 (362) 266 94 43 E-Mail: info@ifyil.com.tr Authorized Signature&Stamp IMPORTER / DEALER CUSTOMER Name: Name Surname: Address: Address: Phone:...
  • Page 49: Warranty Conditions

    WARRANTY CONDITIONS The warranty period starts from the delivery date of the product and is two (2) years. The product is fully in warranty, except for the glass and cast parts. In case the product is found to be defective, Article 11 of the Law No. 6502 on Consumer Protection;...
  • Page 50 Warranty does not covers any damages due to set up ifyil stoves in open air areas, wet places, humid places or any place which directly related to all these places. Warranty does not cover any damages due to not maintenance of product which written in user's guide.
  • Page 51 İFYIL TERMO İklimlendirme San. Ve Tic. Ltd. Şti. Kavak Organize Sanayi Bölgesi 3. Cad. No.11 Kavak / Samsun / Türkiye Tel : +90 362 266 9443 Fax : +90 362 266 9443 Mail : info@ifyil.com.tr www.ifyil.com.tr...