1. G 1.3. Packaging of documentation ENERAL ONSIDERATIONS This manual, as well as any other applicable TEK Biomasse ® is a registered trademark, whose documentation, must be stored diligently so that air conditioning equipment is manufactured by it is available at all times. In case of moving or Vitor Monteiro Lda., and tested in accordance with...
On water models, the installer must inform the user of the following: Do not make electrical connections with • In case of water leaks, it is necessary to temporary or non-insulated cables. turn off the water supply and immediately notify technical support. Check that the equipment ground connection is effective.
glass and door, chimney, among other Exclusions: warranty does cover damage During the first lighting of your equipment, malfunctions arising from the following causes: it is possible that some odors may be released resulting from the natural drying of • Damage caused during...
This is the only fuel indicated for this equipment. Yield and power vary depending on the quality of pellets used. For correct operation you must use pellets according to the characteristics below. Figure 1- Ebony charging cover Technical Fuel Information (Pellets) 5.2. Pellet storage Diameter Length...
The functioning of the stove depends largely on It must be safeguarded that no mechanical the quality and conservation conditions of the exhaust fans or collective ventilation ducts are pellets, for this reason they must be stored in a installed at the installation site. dry place where they do not reach too low In any case, it must be safeguarded that the temperatures.
During installation, structures, coverings, beams, You must also safeguard that this admission will etc., must be protected from combustible or never be obstructed from the outside and that it flammable material and which are exposed to is at least 20 cm from the ground. excessive heat from both the stove and the Outside, you should put protection against rain chimney, particularly when crossing partitions...
If necessary, contact the technical assistance 7.5. Smoke evacuation duct service. The smoke discharge from the stove is with 7.5.1. Basic requirements positive pressure in relation to the surrounding environment, so it is essential to guarantee the tightness of the different joints of the chimney. Below are some proposals for the execution of a The smoke evacuation duct must be independent chimney,...
7.6. Electrical installation Installation must be carried out by qualified personnel according to EN 10683. Ensure that the electrical installation is earthed. With the switch off, connect the cable to the wall socket and plug. Figure 7 Figure 5- Example of installation with wall outlet Turn on the switch to electrically power the stove.
• Clean the equipment only when it is 7.8. Maintenance completely cold and turned off; • The ash compartment must not be When installing equipment, space opened while the stove is operating. Wait required for maintenance and cleaning of the for it to stop and cool down completely to equipment and respective connection and smoke clean the ash.
the material until the temperature of the stove is reduced to 40ºC. 8.4. Unplug the device from the mains Attention! Ensure that device disconnected from the power supply when it is in operation. This process requires that the device is not performing any operations and that the display shows “OFF”.
State Code State Code Operation Verification Check Modulation Ignition-Preheating Phase on 1 Standby STBY Ignition-Pre-Charge Phase on 2 Safety Ignition-Fixed Phase on 3 Extinction Ignition-Variable Phase on 4 Block Stabilization on 5 Recover the ignition 8.7. Messages Description of messages Code Viewing the status of the temperature probes.
Primary airflow velocity; visible Input was set to " Air Flow Air flow * Sensor " Fan* [rpm] Combustion fan speed; visible if P25 ≠ 0 Auger * Power auger connected; visible if P81 ≠ 0 Receive [nr] Selected combustion recipe; visible if P04 > 1 Service Service ' message;...
The system includes three types of programs: Daily, Weekly, Weekend. After selecting the program of your choice: - Select the programming time with the P5 or P4 keys - Enter edit mode (selected time flashes) with P3 key - Change the time with the P5 or P4 keys - Save the program with the P3 key - Enable (a “V”...
Page 17
Allows you to correct the extraction rotation to compensate for a greater or lesser chimney draft. Automatic power Allows you to set the combustion level to automatic Keyboard Menu Shine Allows you to adjust the brightness of the panel. Contrast Allows you to adjust the panel contrast.
Put the brazier back in place ensuring the perfect 9. M alignment of the resistance hole with AINTENANCE respective resistance. Incorrect alignment can cause ignition failure. 9.1. Security measures 9.2.2. Weekly cleaning Before starting maintenance work, make sure that the stove is disconnected from the electricity supply, that the stove is cold and the ashes are Glass cleaning out.
Page 19
Ebony /Slim Model Remove the ash drawer, and open the lower compartment. Clean the exchanger by pulling and pushing the shaft located between the central fins of the grid as shown in the picture below. With the aid of an ash vacuum cleaner, vacuum the ash compartments.
9.2.3. Semi-annual cleaning You must periodically clean the boiler and the smoke collector or for every 600 kg of pellets consumed. Ebony/Slim Model Access to the interior of the equipment is made through the rear panel and side panels. back...
Remove the lid as indicated and clean it using an 9.3.1. Chimney cleaning ash vacuum cleaner and a 20 mm brush. Chimney cleaning should be carried out at least twice a year at the beginning and middle of the winter season or when necessary. This cleaning must be carried out with an 80 mm nylon or steel brush.
Check the condition of the door and glass sealing 9.6. Control maintenance gasket. A seal in poor condition causes poor and program incorrect combustion with a consequent reduction in efficiency. Replace the packing whenever it does not Yearly guarantee correct tightness. Carry out the same check for the ash drawer packing.
10. E RROR CODES Origin Cause Action Er01 Auger boiler safety The water is not circulating. Check the installation. thermostat Wait for the boiler or Circulator pump blocked with hopper to cool down and It occurs if the hopper (85ºc) dirt, installation with air in the for the message Stop or boiler...
Page 24
Er08 Combustion fan encoder. Check the plug and connecting Reset error cable on the fan and controller restart the boiler, if the Occurs if the controller is error persists, call unable to obtain rotational Possible encoder technician. speeds according to the value malfunction defined by it.
Page 25
Er23 Boiler sensor, open The boiler is programmed to Check sensor connection circuit. read one or more of the In case the boiler does following sensors and has not not have DHW, it must detected them: deactivated Boiler temperature changing the following parameters P26=5 and DHW temperature P83=0...