Index Use of the stove ........10 8.1. Useful information ......10 General Considerations ......2 8.2. Lighting ......... 11 1.1. Symbology ........2 8.3. Stop ..........11 1.2. Use ..........2 8.4. Unplug the device from the mains ..11 1.3. Packaging of documentation ....2 8.5.
ENERAL ONSIDERATIONS documentation, must be stored diligently so that it is available at all times. In case of moving or selling the equipment, the documentation must TEK Biomasse ® is a registered trademark, whose attached forwarded air conditioning equipment is manufactured by user/owner.
• In case of water leaks, it is necessary to turn off the water supply and immediately Do not make electrical connections with notify technical support. temporary or non-insulated cables. • System pressure operation must Check that the equipment ground connection is checked periodically.
• Invoice with date of purchase; • Installation compliance certificate issued by the installer. During the first lighting of your equipment, it is possible that some odors may be released resulting from the natural drying of Exclusions: paints and putties. Avoid prolonged warranty does cover...
they be replaced when necessary in the periodic maintenance actions. For correct operation you must use pellets The manufacturer will guarantee replacement according to the characteristics below. parts for the legally prescribed period. Technical Fuel Information (Pellets) Diameter 5. F Length 10 to30 mm Density in the bag...
7. I NSTALLATION To obtain the best performance from the stove and uniform heating of the room, you must comply with some essential rules. Improper installation will compromise the safety and proper functioning of the stove. When installing the equipment, all national and local regulations, as well as European standards, must be observed.
Figure 3- Minimum dimensions to respect the envelope and minimum height of the chimney Figure 2- Minimum dimensions to respect in relation to The manufacturer will not be responsible for adjacent surfaces changes in the properties of the materials surrounding the stove and chimney. The floor protection to support the stove must guarantee fire resistance in accordance with European standards.
In the figure below you will find several examples tightness of the different joints of the chimney. that will help you to verify the stability and The smoke evacuation duct must be independent correction of the flame. from other equipment. To guarantee the correct extraction of the smoke, Correct combustion it is mandatory that the first section of the...
Page 10
Below are some proposals for the execution of a chimney, which should understood schemes, not replacing a specialty project. Figure 5- Example of installation with wall outlet Figure 4- Example of vertical installation Figure 6- Example of installation from the outside...
7.6. Electrical installation Return of wind chimney Installation must be carried out by qualified Er03 Smoke temperature sensor Lack of fuel personnel according to EN 10683. Ensure that the Extinguishing combustion due Low calorific fue electrical installation is earthed. to low smoke temperature, Too-down corre lack of fuel With the switch off, connect the cable to the...
Page 12
Er11 Internal clock error boiler During the Check Phase Up been Call a technician. disconnected from power for a the boiler makes the exhaust Incorrect day and time due to long time and the internal capacity diagnosis. prolonged absence of power battery has discharged, losing supply The maximum reference value...
Electrical in this manual. In order to avoid the risk of fire, you must comply with the instructions contained in point 2.2- User- Security warnings, with special emphasis on the 7.7. Installation test following aspects: • It is forbidden to place clothes to dry 8.2 - Lightingand 8.3- Stopmust be taken into or other objects on the equipment or in its account.
Attention! Ensure that device 8.3. Stop disconnected from the power supply when it is in Stopping is carried out by pressing the ON/OFF operation. This process requires that the device is key for 3s. The word “Deactivation” will appear on not performing any operations and that the the display.
8.5. K100 Control Panel Functions The Main Panel shows: Time and date, chrono activation, combustion power, heating, power, operating mode, ambient temperature and required main temperature keys Occupation Exit Menu/Submenu Ignition/Extinguishing (press 3sec), Error Reset (press 3sec), Chrono On/Off Enter User Menu 1 / submenu, Enter User Menu 2 (press 3 sec.), save data Enter views menu, zoom in Enter views menu, zoom out Occupation...
8.7. Messages Description of messages Code Viewing the status of the temperature probes. The message displayed in the probe Check-Up indicates that the temperature reading on one or more probes is equal to the minimum (0 °C) or maximum value (depends on the probe considered). Check that the probes are not open (0 °C) or that they are short-circuited (maximum value of the temperature scale).
8.9. User Menu 1 Access to the menu is done by pressing P3 Power Combustion By entering this menu, you can change the combustion power of the system. You can configure it in automatic or manual mode: in the first case, the system chooses the combustion power;...
Set the ON time of the first day to the desired value: Ex. 20.30 Set the OFF time of the first day to 23:59 Set the next day's ON time at 00:00 Set the next day's OFF time to the desired value: Ex.
Put the brazier back in place ensuring the perfect 9. M alignment of the resistance hole with AINTENANCE respective resistance. Incorrect alignment can cause ignition failure. 9.1. Security measures 9.2.2. Weekly cleaning Before starting maintenance work, make sure that the stove is disconnected from the electricity Glass cleaning supply, that the stove is cold and the ashes are out.
Page 20
Models Domina/Glam/Prima Air /Stone Clean the exchanger by pulling and pushing the shaft located between the central fins of the grid as shown in the picture below. To access the ash compartment, lightly press the lower cover and move it away as shown in the image below.
9.2.3. Semi-annual cleaning You must periodically clean the boiler and the smoke collector or for every 600 kg of pellets consumed. This cleaning must also include cleaning the smoke extraction fan. Loosen the marked fixing screws. Dump the ash from the drawer, and with the aid And remove the top cover.
9.3.1. Chimney cleaning Chimney cleaning should be carried out at least twice a year at the beginning and middle of the winter season or when necessary. This cleaning must be carried out with an 80 mm nylon or steel brush. Figure 10- Cleaning brush for pellet equipment To ease cleaning, in particular all chimney encrustations, you should use appropriate pellets...
Replace the packing whenever it does not 9.6. Control maintenance guarantee correct tightness. program Carry out the same check for the ash drawer packing. Yearly 9.4. Exterior cleaning Brazier Clean with a dry, non-abrasive cloth. Cleaning the Do not use water or detergents during the exchanger (activate the cleaning process as if it comes into contact with...
10. E RROR CODES Origin Cause Action Er01 Auger boiler safety The water is not circulating. Check the installation. thermostat Wait for the boiler or Circulator pump blocked with hopper to cool down and It occurs if the hopper (85ºc) dirt, installation with air in the for the message Stop or boiler...
Page 25
Er08 Combustion fan encoder. Check the plug and connecting Reset error cable on the fan and controller restart the boiler, if the Occurs if the controller is error persists, call unable to obtain rotational Possible encoder technician. speeds according to the value malfunction defined by it.
Page 26
Er23 Boiler sensor, open The boiler is programmed to Check sensor connection circuit. read one or more of the In case the boiler does following sensors and has not not have DHW, it must detected them: deactivated Boiler temperature changing the following parameters P26=5 and DHW temperature P83=0...