3.3
Connect the 6 kW interconnection cable (NS003104) to the radar
processor
Connect the round pin end (A) of the 6 kW interconnection cable to the scanner connection on the
radar processor as follows:
6 kW Interconnection cable pin details
A
Description/Remarks
1
Scanner Ground
2
Motor Ground
3
Scanner Power
4
Motor Power
5
Video Ground
6
Not used
7
Not used
8
Not used
9
RS-485 Comm+
10
Video
11
Not used
12
Bearing Zero
13
RS-485 Comm–
14
Trigger Ground
15
Trigger
16
Bearing Pulse
Shell
3.4

Install the 6 kW open array

IMPORTANT: Install the open array onto the scanner ONLY after you've connected the 6 kW
interconnection cable to the scanner.
Use the Assembly instruction sheet provided, and check that you've got all the components shown.
Follow the instructions on the Assembly instruction sheet to install the open array.
Northstar 6 kW Radar Installation Manual
Color
AWG size
Blue / Gray (big)
#16
Purple / Brown (big)
#16
Red / Green (big)
#16
Yellow /Pink (big)
#16
Drain wire (coax line)
#24
No connection
No connection
No connection
Yellow (thin)
#24 twist pair
Axis line
#24
No connection
Green (thin)
#24
White (thin)
#24 twist pair
Drain wire
#24
Shield line
#24
Orange (medium)
#18
Braid shield
19