For Suse Linux Enterprise Server Sp3 Using The Gui - Dell PowerVault MD3660i Deployment Manual

Powervault md3660i series storage arrays
Hide thumbs Also See for PowerVault MD3660i:
Table of Contents

Advertisement

3.
If you are using Mutual CHAP authentication, you can set the user name and password for CHAP authentication of
the target(s) by the initiator by editing the following lines:
node.session.auth.username_in=<iscsi_target_username>
node.session.auth.password_in =<CHAP_target_password>
4.
To set up discovery session CHAP authentication, first uncomment the following line:
discovery.sendtargets.auth.authmethod = CHAP
5.
Set a user name and password for a discovery session CHAP authentication of the initiator by the target(s) by
editing the following lines:
discovery.sendtargets.auth.username =<iscsi_initiator_username>
discovery.sendtargets.auth.password =<CHAP_initiator_password>
6.
To set the user name and password for discovery session CHAP authentication of the target(s) by the initiator for
Mutual CHAP, edit the following lines:
discovery.sendtargets.auth.username = <iscsi_target_username>
discovery.sendtargets.auth.password_in = <CHAP_target_password>
7.
The final configuration contained in the /etc/iscsi/iscsid.conf file may look like this:
node.session.auth.authmethod = CHAP
node.session.auth.username = iqn.2005-
node.session.auth.password = password_1
node.session.auth.username_in= iqn.1984-
node.session.auth.password_in = test1234567890
discovery.sendtargets.auth.authmethod = CHAP
discovery.sendtargets.auth.username = iqn.2005-
03.com.redhat01.78b1b8cad821 discovery.sendtargets.auth.password =
password_1
discovery.sendtargets.auth.username = iqn.1984-
123456discovery.sendtargets.auth.password_in =

For SUSE Linux Enterprise Server SP3 Using The GUI

1.
Click Desktop→ YaST→ iSCSI Initiator.
2.
Click Service Start, then select When Booting.
3.
Select Discovered Targets, then select Discovery.
4.
Enter the IP address of the port.
5.
Click Next.
6.
Select any target that is not logged in and click Log in.
7.
Select one of the following:
If you are not using CHAP authentication, select No Authentication. Go to step 8.
or
If you are using CHAP authentication, enter the CHAP user name and password. To enable Mutual CHAP,
select and enter the Mutual CHAP user name and password.
8.
Repeat step 7 for each target until at least one connection is logged in for each controller.
9.
Go to Connected Targets.
10. Verify that the targets are connected and the status is true.
03.com.redhat01.78b1b8cad821
05.com.dell:powervault.123456
05.com.dell:powervault.
test1234567890
41

Advertisement

Table of Contents
loading

Table of Contents