Vanguard VMH26TPB 14 Owner's Operation And Installation Manual page 13

Vent-free propane/lp gas compact classic hearth fireplace
Table of Contents

Advertisement

INSTALLATION
Continued
For Built-In Installation
WARNING: A licensed elec-
trician must connect the wiring
harness to electrical supply fol-
lowing all local codes. Electri-
cian must provide a clamp on
the box cover to secure the wir-
ing. Wiring should be routed
through the bushing in the hole
on the outer casing of heater.
Follow instructions Removing Valve Cover
Shield (page 11), then
1.
Install a snap bushing found in hardware
kit into one of the holes found on rear of
valve cover shield. The other hole is for
a strain relief clamp (not supplied) to
secure incoming electrical supply.
2. Follow steps 2 through 6 in Installing
Blower Assembly, pages 11 and 12.
Also remove black wire from middle
switch terminal 2.
3.
Remove black plastic strain relief and
power cord from switch plate. The
power cord supplied will not be used in
built-in installations. Pop in the plastic
snap bushing found in hardware kit into
the hole left by supply cord/strain relief.
4. A licensed electrician must follow the
wiring diagram to connect incoming
electrical supply to fan kit wiring har-
ness (see Figure 20).
5. Plug power cord to the outlet receptacle
(not provided) as shown in figure 19.
Wind the extra cable in power cord and
and tie it up with the plastic wire strap
(see Figure 21). Set the cable bundle
between the burner bracket and outer
casing, away from the burner.
6. Reinstall valve cover shield.
7. Test to make sure the blower is work-
ing properly.
8.
Reinstall upper louver assembly and
hood if previously removed, (see Figure
16, page 11). Close lower louver door.
107030
110/115
V.A.C.
Figure 20 - Wiring Diagram For Blower Accessory Built-In Installation
Screw
Switch
3
2
1
Red
Blue
Switch
Plate
Plastic
Wire Strap
Valve
Cover
Shield
Box Cover
Figure 21 - Installing Blower Bracket Assembly
Extension Cord
Use extension cord if needed. The cord must
have a three-prong, grounding plug and a
three-hole receptacle. Make sure cord is in
good shape. It must be heavy enough to carry
the current needed. An undersized cord will
cause a drop in line voltage. This will result
in loss of power and overheating. Use a No.
16 AWG cord for lengths less than 50 feet.
13
OWNER'S MANUAL
Fan Switch
(Auto/Off/On)
Auto
1
2
Off
3
Thermostat
Blue
On
Red
Black
White
Green
Blower Bracket
Assembly
Wire
Harness
Power
Cord
Outlet
Receptacle
Wire
Clamp Connector
Harness
(not included)
Switch
(N.O.)
Blue
Blower
Motor
Red
White
Green
Continued