Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
WAGO Manuals
Measuring Instruments
4PU
User manual
WAGO 4PU User Manual
Energy meters with push-in-cage clamp and levers
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
page
of
41
Go
/
41
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
Safety Instructions
Foreword
Certificates
Specifications
Performance Criteria
Basic Errors
Bluetooth Specification
M-Bus Communication Specification
Modbus/Rs485 Communication Specification
Dimensions
Wire Connection
Connection Diagram 879-3000 (4PU)
Connection Diagram 879-3020 (4PS)
Installation
Operation
Display Part 1 (MID Relevant)
Display Part 2 (MID Relevant)
Display Part 3 (Non MID Relevant)
Settings
Bluetooth
Button Settings
Password
Tariff
S0-Impulsausgang
Pulse Type Setting
S0 Pulse Width
Modbus ID
Modbus Baudrate
Modbus Parity
M-Bus ID
M-Bus Baud Rate
Backlight
Powerdown Counter
Trip Counter
OBIS Codes
Combination Code (Adjustable Via Modbus, M-Bus & Bluetooth)
Troubleshooting
Errors / Diagnostics Display
Technical Support
Appendix 1 - Multi Tariff Function
A1.1 How to Switch between T1 und T2
A1.2 How to Switch between T3 and T4
Appendix 2 - M-Bus
A2.1 Communication Via M-Bus
A2.2 M-Bus Register Map
A2.3 M-Bus Write Registers
Appendix 3 - Modbus
A3.1 Communication Via Modbus
A3.2 Modbus Register Map
A3.3 Modbus Write Register
Appendix 4 - Bluetooth
A4.1 Bluetooth App
A4.2 Connect the Meter
A4.3 Device Page
A4.4 Read Meter Data
A4.5 Save Meter Data
A4.6 Change Settings
Advertisement
Quick Links
Download this manual
WAGO Energy Meters (MID)
with Push-in-CAGE CLAMP® and Levers
879-3020
User manual
Version: 052021V1.1
© 2021 Wago. All rights reserved.
4PS
879-3000
4PU
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the 4PU and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for WAGO 4PU
Measuring Instruments WAGO 4PS User Manual
Energy meters with push-in-cage clamp and levers (41 pages)
Measuring Instruments WAGO 879-3000 4PU Operating Instructions Manual
Energy meters with push-in cage clamp and lever (39 pages)
Measuring Instruments WAGO SYSTEM 750 User Manual
3-phase power measurement module (96 pages)
Summarization of Contents
Safety Instructions
Information for Your Own Safety
Critical safety information, warnings, and cautions for operating the meter.
Qualified Personnel Requirements
Specifies that only qualified personnel should install and operate the device.
Intended Use and Proper Handling
Defines the device's intended applications and guidelines for safe handling and operation.
Foreword
Certificates
Product Specifications
Performance Criteria
Details operating humidity, storage humidity, accuracy class, and temperature range.
Basic Error Specifications
Lists acceptable error margins for various current and power factor conditions.
Bluetooth Communication Specification
Outlines the Bluetooth protocol and frequency range supported by the meter.
M-Bus Communication Specification
Details M-Bus communication parameters like bus type, baud rate, range, and protocol.
Modbus/RS485 Communication Specification
Specifies Modbus/RS485 communication parameters including bus type, protocol, and baud rate.
Device Dimensions and Weight
Provides physical dimensions (height, width, depth) and net weight of the energy meter.
Wire Connection Guidelines
Explains the connection technology and recommended wire types for WAGO series 2616 and 2604.
4PU Connection Diagrams
Illustrates connection diagrams for different configurations of the 4PU model.
4PS Connection Diagrams
Illustrates connection diagrams for different configurations of the 4PS model.
Installation Guide
Installation Safety Precautions
Critical safety warnings before and during installation, including power off and tool usage.
Installation Environment and Mounting
Guidelines for meter placement, protection against dust, ventilation, and DIN rail mounting.
Meter Operation
Display Part 1 (MID Relevant)
Shows MID relevant information like version, serial number, tariff, and measurement units.
Display Part 2 (MID Relevant)
Displays MID relevant measurement values identified by OBIS codes.
Display Part 3 (Non-MID Relevant)
Shows non-MID relevant data such as current direction, frequency, and power values.
Settings Menu Navigation
Explains how to enter the settings mode using the front buttons and navigate options.
Bluetooth Activation
Describes how to activate Bluetooth communication on the energy meter.
Button Settings Configuration
Details how to access and configure various settings like password, tariff, Modbus, etc.
SO Pulse Output Settings
Covers configuration of pulse output type, width, and related parameters.
Communication Settings (Modbus/M-Bus)
Configuration options for Modbus ID, Baudrate, Parity, and M-Bus ID/Baudrate.
Display and Counter Settings
Configuration for backlight, powerdown counter, and trip counter settings.
OBIS Code Identification
Lists and explains the OBIS codes used to identify measurement values on the display.
Combination Code for Energy Display
Explains how to set different calculation methods for displaying total energy usage.
Troubleshooting and Support
Maintenance Safety Precautions
Safety warnings and precautions for performing maintenance or repair on the meter.
Common Issues and Solutions
Guides users through common problems like LED not flashing or register not counting, with verification steps.
Error and Diagnostics Display
Explains how the meter indicates errors and the meaning of diagnostic display codes.
Technical Support Contact Information
Provides contact details for WAGO technical support for product inquiries.
Appendix 1: Multi-Tariff Function
Switching Between Tariffs T1 and T2
Describes the procedure for activating tariffs T1 and T2 via external voltage connection.
Switching Between Tariffs T3 and T4
Explains how to activate tariffs T3 and T4 using Bluetooth, Modbus, M-Bus, or button functions.
Appendix 2: M-Bus Communication
Communication via M-Bus
Details how to establish M-Bus communication with the meter using a PC and converter.
M-Bus Register Map
Provides a comprehensive list of M-Bus registers, their contents, and data types.
M-Bus Write Registers
Outlines commands and values for writing data to M-Bus registers.
Appendix 3: Modbus Communication
Communication via Modbus
Explains how to establish Modbus communication with the meter using an RS485 converter.
Modbus Register Map (Read)
Lists Modbus registers for reading data, including address, content, function code, and data type.
Modbus Register Map (Write)
Lists Modbus registers for writing data, including address, command, and new value.
Appendix 4: Bluetooth Configuration
WAGO Energy Meter Configurator App
Introduction to the smartphone app for reading and configuring meters via Bluetooth.
Connecting the Meter via Bluetooth
Steps for connecting the meter using the app's Scan Bluetooth or Scan QR functions.
Device Information Page
Displays meter type, serial number, software version, and checksums after connection.
Reading Meter Data
Explains how to access and view energy and instantaneous values through the app.
Saving Meter Data
Instructions on how to save and share meter data locally or via other channels.
Changing Meter Settings
Guide to selecting and saving individual or all settings, including password entry.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the 4PU and is the answer not in the manual?
Questions and answers