Connecting Fireplace To Gas Supply - Desa Vanguard VCGF30PR Owner's Operation And Installation Manual

Desa owner's operation and installation manual unvented (vent-free) catalytic propane/lp gas fireplace vcgf30pr
Table of Contents

Advertisement

INSTALLATION
Continued
We recommend that you install a sediment
trap in supply line as shown in Figure 18,
page 10. Locate sediment trap where it is
within reach for cleaning. Install in piping
system between fuel supply and heater. Lo-
cate sediment trap where trapped matter is
not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps them
from going into fireplace gas controls. If
sediment trap is not installed or is installed
wrong, fireplace may not run properly.
CONNECTING FIREPLACE
TO GAS SUPPLY
Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not
provided)
1. Remove front window assembly. Lo-
cate two phillips-head screws at top
corners of front window assembly. Re-
move and save these screws. Carefully
lift front window assembly up and out
from fireplace front.
2.
Remove screws that attach log base as-
sembly to fireplace (see Figure 20). Care-
fully lift up log base assembly and re-
move from fireplace without disturbing
the brick liner panels (see Figure 20).
Figure 19 - Removing Front Window
Assembly
104637
CAUTION: Do not pick up log
base assembly by burners. This
could damage burners. Only
handle base by grates.
3. Route flexible gas line provided by in-
staller from equipment shutoff valve to
fireplace. Route flexible gas supply line
through one of the access holes.
NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
from the fireplace (see Figure 21).
The flexible gas supply line con-
nection to the equipment shutoff
valve should be accessible.
Figure 20 - Removing Log Base Assembly
From Fireplace
11
OWNER'S MANUAL
4.
Attach gas line from gas supply (see
Figure 21). Check gas connection of
flexible gas line attached to gas regu-
lator of fireplace (see Figure 21).
5.
Check all gas connections for leaks. See
Checking Gas Connections, page 12.
6. Replace log base assembly back into
fireplace. Feed flexible gas line into fire-
place base area while replacing log base
assembly. Make sure the entire flexible
gas line is in fireplace base area. Reat-
tach log base assembly to fireplace with
screws removed in step 2.
To Fireplace
Gas Regulator
Figure 21 - Attaching Flexible Gas
Lines Together
Flexible Gas Line
from Equipment
Shutoff Valve
Equipment
Shutoff Valve
To External
Provided by
Regulator
Installer
Continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF