Table 10
FA MIB 2.2 objects, descriptions, and values (continued)
Object
connUnitTable
connUnitId
connUnitGlobalId
connUnitType
connUnitNumports
connUnitState
connUnitStatus
connUnitProduct
connUnitSn
connUnitUpTime
connUnitUrl
connUnitDomainId
connUnitProxyMaster
connUnitPrincipal
connUnitNumSensors
connUnitStatusChangeTime
connUnitConfiguration
ChangeTime
connUnitNumRevs
connUnitNumZones
connUnitModuleId
connUnitName
connUnitInfo
connUnitControl
Description
Includes the following objects as specified by the FA MIB2.2 Spec
Unique identification for this
connectivity unit
Same as connUnitId
Type of connectivity unit
Number of host ports in the
connectivity unit
Overall state of the connectivity unit
Overall status of the connectivity unit
Connectivity unit vendor's product
model name
Serial number for this connectivity
unit
Number of centiseconds since the
last unit initialization
Same as systemURL
Not used; set to all 1s as specified by
the FA MIB2.2 Spec
Stand-alone unit returns yes for this
object
Whether this connectivity unit is the
principal unit within the group of
fabric elements. If this value is not
applicable, returns unknown.
Number of sensors in the
connUnitSensorTable
Same as statusChangeTime
Same as
configurationChangeTime
Number of revisions in the
connUnitRevsTable
Not supported
Not supported
Settable: Display string containing a
name for this connectivity unit
Settable: Display string containing
information about this connectivity
unit
Not supported
HP StorageWorks 2000 G2 Modular Smart Array Reference Guide
Value
Total of 16 bytes comprised of 8
bytes of the node WWN or similar
serial number-based identifier (for
example, 1000005013b0521 1) with
the trailing 8 bytes equal to zero
Same as connUnitId
storage-subsystem[1 1]
Number of host ports
online[2] or unknown[1], as
appropriate
ok [3], warning[4], failed[5], or
unknown[1], as appropriate
Model string
Serial number string
0 at startup
Same as systemURL
0xFFFF
yes [3] since this is a stand-alone unit
unknown[1]
33
Same as statusChangeTime
Same as
configurationChangeTime
16
0
16 bytes of 0s
Default: Uninitialized Name
Default: Uninitialized Info
invalid[2] for an SNMP GET
operation and not settable through
an SNMP SET operation.