Configuring the System with RAID ADG
The procedure for configuring a system with RAID ADG depends on whether it is a
new system and what operating system it uses. This section gives an overview of the
procedure. For more detailed information, refer to the user guide for the array
controller that the system is using.
NOTE: The maximum size of a logical drive that can be configured through ACU is 2 TB.
However, some operating systems do not support logical drives that are larger than 502 GB.
Refer to the operating system documentation for details.
Configuring a New System
Windows NT and Windows 2000
There are three main steps to configure a new system for RAID ADG:
1. Set up an array.
2. Assign hard drives to the array.
3. Create logical drives within the array.
Setting Up an Array
1. Double-click the ACU icon on the desktop.
2. Select the controller from the drop-down list in the top left corner of the main
ACU screen.
3. Click Settings in the Controller box in the top right corner of the main ACU
screen.
4. Set the rebuild priority, expansion priority, and accelerator ratio.
5. Click Done to activate the settings and return to the main ACU screen.
Assigning Hard Drives to the Array
1. Click Create Array in the Controller box.
Compaq Advanced Data Guarding Option Software Reference Guide
System Setup
2-3