Inspecting Burner; To Turn Off Gas To Appliance; Manual Lighting Procedure - Desa CGN18C Owner's Operation And Installation Manual

Desa blue flame vent free natural gas heater models rn30c, cgn18c owner's operation and installation manual
Table of Contents

Advertisement

OPERATING
HEATER
Continued
INSPECTING
BURNER
101806

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater
1. Turn control knob clockwise
2. Press in control knob and turn clockwise
3. Turn off all electric power to the appliance if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
1. Turn control knob clockwise

MANUAL LIGHTING PROCEDURE

1. Remove front panel (see Figure 5, page 11).
2. Follow steps 1 through 5 under Lighting Instructions, pages 17 and 18.
3. With control knob pressed in, strike match. Hold match to pilot until pilot
lights.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob.
5. Replace front panel.
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
Figure 17 shows a correct pilot flame pattern. Figure 18 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.
Thermocouple
Figure 17 - Correct Pilot Flame Pattern
Thermocouple
Figure 18 - Incorrect Pilot Flame Pattern
to the PILOT position.
Clockwise
to the OFF position.
Clockwise
to the PILOT position.
Clockwise
Pilot Burner
Pilot Burner
Continued
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rn30c

Table of Contents