FIREPLACE
INSTALLATION
Continued
8. Plug in blower power cord.
a. If your fireplace system is installed
as a freestanding unit with an ac-
cessory mantel, determine whether
the power cord will exit the left side
or the right side of the firebox. In-
stall one plastic bushing provided
1
into the 1
/
" hole in the outer cas-
2
ing through which the power cord
will exit. Install the second plastic
bushing provided into the floor sup-
port bracket if exiting through the
right side (see Figure 33). Route
power cord through (both) plastic
bushing(s) and plug the power cord
into a properly grounded 3-prong
wall receptacle near the firebox.
b. If your fireplace system installation
is recessed and/or pre-wired, a
qualified installer must make all elec-
trical connections for the outlet kit
included with the fireplace.
Lower Rear
Wall of
Firebox
Wrapper
Lower Louver
Blower
Panel
Screws
Figure 30 - Mounting Blower to Firebox
105982
9.
Check to make sure that the power cord
is completely clear of the blower wheel
and that there are no other foreign ob-
jects in blower wheel. Turn blower on
and check for operation. Turn blower
off by rotating knob fully counterclock-
wise before continuing.
WARNING: Never touch the
blower wheel while in operation.
10. Peel off the backing paper and stick the
supplied wiring diagram decal on the
firebox bottom approximately 3" to the
right of the blower speed control
bracket (Figure 33).
Figure 31 - Locating Thermal Switch Against Back of Firebox
Speed
Control
Control
Knob
Exhaust Port
Figure 32 - Attaching Speed Control to
Firebox
Top
Mounting
Tab
Wiring
Diagram
Blower Speed
Control Bracket
Figure 33 - Installing Plastic Bushing and
Wiring Diagram Sticker
Thermal Switch
Control Shaft
Locknut
Plastic Bushing
17
OWNER'S MANUAL
WARNING: Failure to position
the parts in accordance with sup-
plied diagrams or failure to use
only parts specifically approved
with this heater may result in dam-
age or personal injury.
11. Connect or reconnect gas supply to fire-
place per Connecting Fireplace to Gas
Supply on page 19 of this manual.
WARNING: A qualified ser-
vice person must connect fire-
place to gas supply. Follow all
local codes.
Firebox Bottom
Thermal
Switch
Thermal
Switch
Bracket
Firebox Back
Firebox Flange
Blower
Side View
Continued

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdv34pa

Table of Contents

Save Article as PDF