Page 1
SERVICE MANUAL MODEL TYPE: YS 1064 TRAYNOR YCS50 WEB ACCESS: http://www.yorkville.com WORLD HEADQUARTERS CANADA U.S.A. Yorkville Sound Yorkville Sound Inc. 550 Granite Court 4625 Witmer Industrial Estate Pickering, Ontario Niagara Falls, New York L1W-3Y8 CANADA 14305 USA Voice: (905) 837-8481...
IMPORTANT SAFETY INSTRUCTIONS This lightning flash with arrowhead symbol, within The exclamation point within an equilatereal triangle is an equilateral triangle, is intended to alert the user to intended to alert the user to the presence of important the presence of uninsulated “dangerous voltage” operating and maintenance (servicing) instructions in within the product’s enclosure that may be of sufficient the literature accompanying the appliance.
Page 4
YCS50H MODEL TYPE: YS1064 MODEL TYPE: YS1067 Block Diagram for YCS50/50H/YCS90 YCS50H Tube Configuration D E S I G N E D A N D M A N U F A C T U R E D B Y Y O R K V I L L E S O U N D SPLITTER PREAMP 12AX7...
Page 5
Part# Description Labeled Components 8268 TRAYNOR LOGO PLASTIC NICKEL PLA CORNER,2 LEGS NOTCED BLACK POWD 8570 8451 10" STRAP HANDLE,BLACK METAL EN #4 X 1/4 PAN PH TYPE A ZINC / #10 WASHER 8770/8817 7081 12" 8R 60WPGM SPKR CELEST VI 3698 SPST ROKR SW QUIK 180"...
Page 8
SEE LAYOUT DIAGRAM M1292 PRODUCTION NOTES M1292.PCB_DATABASE_HISTORY MODEL(S):- YCS50 Output DATE VER# DESCRIPTION OF CHANGE 1. APPLY RTV TO C65 AND C67. 19-JUN-2007 1.00 FIRST DESIGN 2. BRAKE ALONG THE LINE SPECIFIED ON THE BOARD BEFORE 11-FEB-2008 1.01 REVISION PER PC7456 14-APR-2008 1.02 CHANGE VALUE OF R49 TO 33K PER PC7535...
Page 11
220P 100V 1/4W 620R 1/4W MINI 100V 220P R122 4423 1/4W P18:A 1/4W 5B LIN FX Ret 2 -15V 4417 1/4W P12:A Send Level U3:B 1/4W 620R U3:C 1/4W U3:A MINI 4423 TL072 1/4W 1/4W EFF.RETURN P13:A EFF.SEND FX Ret 1 1/4W TL072 +15V...
Page 12
BREAK PANEL IN 2 ALONG THIS SCORE LINE BEFORE CLINCHING. SCORE 5B LIN Gold Gold C127 Gold LINE.OUT 1.0W 450V C108 3923 R T V Gold Gold Gold 4417 470P DPDT SLID 5959 3732 3732 4ohm/8ohm R7X2 113K 3732 Gold Gold Gold R T V...
Page 13
SEE LAYOUT DIAGRAM PRODUCTION NOTES M1294 YCS50 / 90 1. DO NOT STUFF the headphone circuit parts that have a large 'X' through them. The DNS parts also have X shown on the actual board on the silkscreen legend. 2. Lay C126 flat before RTVing. 3.
Page 16
BREAK PANEL IN 2 ALONG THIS SCORE LINE BEFORE CLINCHING. SCORE M1353 V4.00 YCS50/50H 100R 100R 470U R184 1.0W 1.0W 1000U R T V R185 8799 5618 100U StepAndRepeat - X3@6.000Y2@5.500 5635 .4"Fins 3692 4007 5635 ClinchRepeats - X3@6.000Y1@5.500 R T V 3692 4007 To_PowerAmp...
Page 17
SEE LAYOUT DIAGRAM PRODUCTION NOTES X8001(M1295, M1353, M1357) X8001.PCB_DATABASE_HISTORY 1. BEFORE CLINCHING, BREAK PANEL IN 2 ALONG LINE WHERE INDICATED. MODEL(S):- YCS50, 50H, 90, 30 DATE VER# DESCRIPTION OF CHANGE 2. B.A. WILL PUT C86 AND C87 AS FOLLOWS 26-FEB-2007 1.00 2nd Proto 20-MAR-2007...
Page 18
5B LIN 4417 Send Level 3424 DPDT SLID 4ohm/8ohm OD GAIN BOOST LEVEL OD VOLUME TREBLE BASS REVERB1 FX Ret 1 500K 500K 500K 100K 500K BOOST Modern Scoop 4425 4425 4425 4424 4423 4425 4423 4423 Alternate Alternate Alternate MASTER VOLUME Presence Resonance...
90W mode (YCS90). A speaker/load should be connected at all times when amplifier is powered. Products Affected Traynor YCS50, 2. Turn the amplifier on; allow it to warm up for 2-3 minutes. YCS50H & YCS90 3. Once the amplifier is warmed up, make sure the amplifier is out of Standby mode.