WIRE CONNECTIONS
Extended Leads from 860 Phantom to Terminal Strip to Connecting Block
The extended connection between the IR receiver and the connecting block
should be made with twisted-pair wiring (i.e., CAT-5e cable). It may be nec-
essary to use shielded twisted-pair wiring if the wiring is exposed to inter-
ference from power wiring centers or from broadcast signals (FM, TV, etc.)
located nearby. The installer should determine the cable type needed to suit
the local conditions of the installation. A terminal strip is included for
extending the leads.
Blue/White
Open
Green
Blue
Green/White
Blue/White
Brown
Brown/White
Orange Pair
Open
CAT-5e cable
Brown/White
Orange/White
860
CAT-5e
SIGNAL
BL
SIGNAL
+12VDC
GR/GRW +12VDC
GND
BR/BRW
OR/ORW
BLW
Russound offers both CAT-5e cable (AWCAT5) and shielded twisted-pair
cable (AW2260AB) which are suitable for IR installations. Contact Russound
for ordering information.
860 Phantom
SIGNAL
(White)
Terminal
Strip
+12VDC
(Black)
Drain Orange Pair
and Blue/White to
S
TATUS
GND on 857
+12VDC
P
OWER
+12VDC
Green
Green/White
IR R
I
ECEIVER
N
Brown
IR C
I
OMMON
N
+
12VDC
GND
STATUS
Orange
SIGNAL
DESIGNED IN USA MADE IN KOREA
Blue
857
GND
GND
GND
PACKAGE INCLUDES:
SaphIR 860 Phantom IR Receiver (1)
Terminal Strip (1)
Screws (2)
Two-way Mounting Tape (1)
SPECIFICATIONS
GND
(Black)
Mounting Cord Length: 6.5 ft.
857
CONNECTING
BLOCK
Receive Frequency: 36kHz to 58kHz
Transmit Frequency: 40kHz and 56kHz
Range: On Axis – 55ft to 80ft
30º Off Axis – 30ft to 55ft
Power: 12VDC 31mA max.