Splash Lab TSL.990 Installation & Maintenance

Deck mounted sensor tap

Advertisement

Quick Links

TSL.960 / TSL.990
deck mounted sensor tap

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TSL.990 and is the answer not in the manual?

Questions and answers

Summary of Contents for Splash Lab TSL.990

  • Page 1 TSL.960 / TSL.990 deck mounted sensor tap...
  • Page 2 Safety and Warnings Box Contents Diagram Technical Data Before You Install Technical Drawing How To Install Commissioning & Operation Troubleshooting Cleaning Maintenance Warranty Back Cover Contact Details TSL.960 / TSL.990 MANUAL...
  • Page 3 (see back page for more details). Ensure plumbing is installed correctly before activating water supply. All plumbing is to be installed in accordance with applicable codes and regulations. For more information contact: Tel: +44 (0)161 482 7000 Email: technical@thesplashlab.com TSL.960 / TSL.990 MANUAL...
  • Page 4: Box Contents

    TSLP.900.020 Base O-ring TSLP.104 TSLP.104 TSLP.104 TSLP.104 Anti-rotation plate TSLP.900.000 TSLP.900.000 TSLP.900.000 TSLP.900.000 Aerator - 1.89lpm - Spray pattern TSLP.260063 TSLP.260063 TSLP.260063 TSLP.260063 Solenoid connector cable TSLP.120032 TSLP.120032 TSLP.120032 TSLP.120032 Aerator key TSLP.260050 TSLP.260050 TSLP.260050 TSLP.260050 TSL.960 / TSL.990 MANUAL...
  • Page 5 Tap assembly Anti-rotation plate Backnut Solenoid valve Inline filter / strainer Solenoid connector cable Mains power supply unit Battery holder TSL.960 / TSL.990 MANUAL...
  • Page 6: Technical Data

    AISI 304 Stainless Steel Coating Type PVD (colours only) Weight 1.4Kg Aerator Cascade flow Min/Max pressure 0.5 - 7.5 bar Flow Rates 3.8l/min [0.5gpm] Also available as optional extras: 1.35l/min [0.35gpm] 1.89l/min [0.5gpm] Max Hot Water Temperature 60°C TSL.960 / TSL.990 MANUAL...
  • Page 7 Security Time-out 30 seconds Operating Temperature 0 to 50ºC Response Time (max) < 300ms Compliance WRAS Certificate 2012304 PSU conforms to RoHS, REACH, EN15091 BREEAM Qualities for up to 5 credits as part of water efficiency assessment TSL.960 / TSL.990 MANUAL...
  • Page 8: Before You Install

    Caution The TSL.960 / TSL.990 parts must be put together correctly before installation. All parts must be installed correctly before powering up the system. Access Requirements It is critical all components which require fixing behind the wall are easily accessible at all times during installation and routine maintenance.
  • Page 9: Technical Drawing

    TO SOLENOID VALVE SENSOR CONNECTOR CABLE TO POWER SUPPLY POWER SUPPLY SOLENOID VALVE 200mm LEAD LENGTH SOLENOID CONNECTOR LEAD 700MM FLEXIBLE HOSE 400mm LEAD LENGTH 400mm LEAD LE 200MM LEAD LENGTH POWER SUPPLY SOLENOID VALVE SOLENOID VALVE TSL.960 / TSL.990 MANUAL...
  • Page 10 TO SOLENOID VALVE SENSOR CONNECTOR CABLE TO POWER SUPPLY POWER SUPPLY SOLENOID VALVE 200mm LEAD LENGTH SOLENOID CONNECTOR LEAD 700MM FLEXIBLE HOSE 400mm LEAD LENGTH 200MM LEAD LENGTH 400mm LEAD LE SOLENOID VALVE POWER SUPPLY SOLENOID VALVE TSL.960 / TSL.990 MANUAL...
  • Page 11: How To Install

    For countertop fitment, drill 35mm installation. diameter hole in countertop. Insert the tap through hole in basin or Slide the anti-rotation plate and fixing countertop. nut over flexi hose and sensor cable and onto mounting shank. TSL.960 / TSL.990 MANUAL...
  • Page 12 Tighten using a provided. spanner. Position the power supply to the Connect the power supply cable to the underside of the unit. Before fixing sensor cable. into place ensure cables can reach connector positions. TSL.960 / TSL.990 MANUAL...
  • Page 13 Connect the solenoid cable connector to Fit the flexible hose nut onto the solenoid the sensor connector. adapter TSL.960 / TSL.990 MANUAL...
  • Page 14 WARNING: Ensure all connections are fully tightened to ensure full seal of the tap. The product is now ready to be wired into the spur and tested and commissioned accordingly. TSL.960 / TSL.990 MANUAL...
  • Page 15: Operation

    The user is to activate the tap by placing their hands within the range of the infra-red sensor, to cause the solenoid valve to open for a preset time. The valve will close a set time after the user’s hands have been removed from the detection range. TSL.960 / TSL.990 MANUAL...
  • Page 16: Troubleshooting

    Aerator is blocked with Remove aerator and clean Water flow reduced scale or debris. or replace. Debris or scale in solenoid Remove solenoid and valve. clean and replace valve. TSL.960 / TSL.990 MANUAL...
  • Page 17 Use a soft cloth or sponge with a mild solution of soapy water as part of the regular washroom janitorial routine. Do not use abrasive or cream cleaners as these will damage the surface finish. If further information is required, contact The Splash Lab technical team for more detailed stainless steel care guidelines. TSL.960 / TSL.990 MANUAL...
  • Page 18: Maintenance

    Reassemble the parts as shown. Restore the incoming water supply checking there are no water leaks. Reconnect the solenoid cable to the power supply. Note: the directional flow of water is shown on the solenoid housing with an arrow. TSL.960 / TSL.990 MANUAL...
  • Page 19: Warranty

    Sensor taps 2 years parts & labour If a defect is found in normal use, The Splash Lab will, at their discretion, repair, provide a replacement part or product, or make appropriate adjustments. Damage caused by accident, misuse, or abuse is not covered by this warranty. Improper care and cleaning will void the warranty.
  • Page 20 contact General information info@thesplashlab.com +44 (0) 161 482 7000 Technical support technical@thesplashlab.com For further contact information visit: www.thesplashlab.com...